3250 S CLUB DR 90064
Certificate Information: 3250 S CLUB DR 90064
- Application / Permit
- 21014-20000-00292
- Plan Check / Job No.
- B21VN00773
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 3'-3" x 16'-9" 1st floor addition, 6'-10" x 13'-7" second floor addition, 14' x 10' second floor addition, and remodel throughout existing single family dwelling. Add new elevator, remove 18'-6" x 14' portion of covered patio and replace with trellis.
- Permit Issued
- Issued on 4/15/2022
- Issuing Office
- Current Status
- CofO Issued on 3/5/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/22/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 1/28/2021 | JEROME MAGAT PALMA |
| Corrections Issued | 2/2/2021 | JEROME MAGAT PALMA |
| Quality Review Completed | 2/19/2021 | OMID HEDAYAT |
| Plan Check Approved | 3/23/2021 | JEROME MAGAT PALMA |
| Building Plans Picked Up | 3/24/2021 | APPLICANT |
| Issued | 4/15/2022 | APPLICANT |
| CofO in Progress | 3/5/2024 | OGANES TARAKHCHYAN |
| Permit Finaled | 3/5/2024 | DANIEL ORRANTE |
| CofO Issued | 3/5/2024 | DANIEL ORRANTE |
| Permit Finaled | 3/5/2024 | DANIEL ORRANTE |
Permit Application Clearance Information
| Specific Plan | Cleared | 2/22/2021 | LOUIS ORTEGA |
| Specific Plan | Cleared | 3/8/2021 | PEDRO AYALA |
| Roof/Waste drainage to street | Cleared | 3/9/2021 | CATHERINE ADROVER |
| Eng Process Fee Ord 176,300 | Cleared | 3/15/2021 | CATHERINE ADROVER |
| Grading Pre-Inspection | Cleared | 3/23/2021 | JEROME MAGAT PALMA |
Contact Information
| Contractor | G E Builders Inc; Lic. No.: 932264-B | 22312 KINZIE STREET CHATSWORTH, CA 91311 |
| Engineer | Shah,, Kamal Rajendra; Lic. No.: C46200 | 28611 HASKELL CANYON RD SANTA CLARITA, CA 91390 |
Inspector Information
| ASHLEY THOMPSON, (310) 914-3897 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 8/25/2022 | Approved | OGANES TARAKHCHYAN |
| Footing/Foundation/Slab | 8/25/2022 | Approved | OGANES TARAKHCHYAN |
| PLUMBING-Rough | 8/25/2022 | Partial Approval | OGANES TARAKHCHYAN |
| Underground Mechanical | 8/25/2022 | Approved | OGANES TARAKHCHYAN |
| Footing/Foundation/Slab | 8/26/2022 | Partial Approval | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 11/18/2022 | Partial Approval | OGANES TARAKHCHYAN |
| ELECTRICAL-Rough | 2/1/2023 | Not Ready for Inspection | ASHLEY THOMPSON |
| HVAC-Final | 2/1/2023 | Corrections Issued | ASHLEY THOMPSON |
| HVAC-Rough | 2/1/2023 | Corrections Issued | ASHLEY THOMPSON |
| PLUMBING-Rough | 2/1/2023 | Corrections Issued | ASHLEY THOMPSON |
| HVAC-Rough | 2/9/2023 | Corrections Issued | ASHLEY THOMPSON |
| HVAC-Rough | 3/1/2023 | Approved | ASHLEY THOMPSON |
| PLUMBING-Rough | 3/6/2023 | Approved | ASHLEY THOMPSON |
| Underground Mechanical | 3/15/2023 | Partial Approval | CLAYTON GRAHAM |
| Deputy Wood Construction | 3/23/2023 | Conditional Approval | JEREMY TODD |
| Floor/Roof Diaphrgm/Shear Wall | 3/24/2023 | Corrections Issued | ASHLEY THOMPSON |
| Shower Pan | 3/24/2023 | Approved | ASHLEY THOMPSON |
| Floor/Roof Diaphrgm/Shear Wall | 4/4/2023 | Partial Approval | ASHLEY THOMPSON |
| ELECTRICAL-Rough | 4/13/2023 | Approved | ASHLEY THOMPSON |
| Rough-Elec/Plmb/HVAC | 4/13/2023 | Approved | ASHLEY THOMPSON |
| Floor/Roof Diaphrgm/Shear Wall | 4/26/2023 | Partial Approval | CLAYTON GRAHAM |
| Green Building Rough | 4/26/2023 | Not Ready for Inspection | CLAYTON GRAHAM |
| Interior/Exterior Lathing | 4/26/2023 | Partial Approval | CLAYTON GRAHAM |
| Insulation | 4/28/2023 | Corrections Issued | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 5/2/2023 | Not Ready for Inspection | CLAYTON GRAHAM |
| Green Building Rough | 5/2/2023 | Not Ready for Inspection | CLAYTON GRAHAM |
| Interior/Exterior Lathing | 5/2/2023 | Not Ready for Inspection | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 5/5/2023 | Corrections Issued | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 5/8/2023 | Approved | CLAYTON GRAHAM |
| Green Building Rough | 5/8/2023 | Approved | CLAYTON GRAHAM |
| Insulation | 5/8/2023 | Approved | CLAYTON GRAHAM |
| Drywall Nailing | 5/18/2023 | Approved | CLAYTON GRAHAM |
| Interior/Exterior Lathing | 6/7/2023 | Approved | CLAYTON GRAHAM |
| Gas Test | 11/21/2023 | Approved | OGANES TARAKHCHYAN |
| PLUMBING-Final | 12/7/2023 | Approved | MICHAEL PELHAM |
| ELECTRICAL-Final | 12/21/2023 | Corrections Issued | BEN MOLSTAD |
| ELECTRICAL-Final | 1/3/2024 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| ELECTRICAL-Final | 1/10/2024 | Approved | OGANES TARAKHCHYAN |
| HVAC-Final | 1/22/2024 | Corrections Issued | OGANES TARAKHCHYAN |
| HVAC-Final | 2/27/2024 | Approved | OGANES TARAKHCHYAN |
| Final | 3/4/2024 | OK to Issue CofO | OGANES TARAKHCHYAN |
| Footing/Foundation/Slab | 3/4/2024 | Approved | OGANES TARAKHCHYAN |
| Green Building Final | 3/4/2024 | Approved | OGANES TARAKHCHYAN |
| SGSOV-Seismic Gas S/O Valve | 3/4/2024 | SGSOV Approved | OGANES TARAKHCHYAN |
| Smoke Detectors | 3/4/2024 | Approved | OGANES TARAKHCHYAN |