5631 N WILLIS AVE 91411

Certificate Information: 5631 N WILLIS AVE 91411

Application / Permit
21014-20000-00172
Plan Check / Job No.
B21VN00441
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ADDITION OF A 14'-10" x 33'-6" ADDITION TO CONSIST OF A BEDROOM AND A FULL BATHROOM. DESIGN PER WFPP.
Permit Issued
Issued on 1/19/2022
Issuing Office
Current Status
CofO Issued on 9/15/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 1/13/2021 APPLICANT
Assigned to Plan Check Engineer 1/26/2021 LUIS RINCON
Corrections Issued 1/27/2021 LUIS RINCON
Applicant returned to address corrections 6/1/2021 LUIS RINCON
Applicant returned to address corrections 6/30/2021 LUIS RINCON
Applicant returned to address corrections 10/29/2021 LUIS RINCON
Plan Check Approved 1/14/2022 ANGELICA MARTINEZ
Issued 1/19/2022 APPLICANT
Building Plans Picked Up 1/24/2022 APPLICANT
CofO in Progress 9/15/2022 ALAN MORELOS
CofO Issued 9/15/2022 MICHAEL SMITH
Permit Finaled 9/15/2022 MICHAEL SMITH

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 1/13/2022 CARLOS AGUILERA
Roof/Waste drainage to street Cleared 1/13/2022 CARLOS AGUILERA

Contact Information

Contractor Owner-Builder       ,
Engineer Zhong,, Raymond Meng; Lic. No.: M27635 2416 W VALLEY BLVD      ALHAMBRA, CA 91803

Inspector Information

JOSE AVILA, (818) 374-1173 Office Hours: 7:00-8:00 AM MON-FRI
VINCENT HANLEY, (818) 374-1173 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 1/24/2022 Approved RICHARD DOCKUS
Floor/Roof Diaphrgm/Shear Wall 2/1/2022 Not Ready for Inspection RICHARD DOCKUS
PLUMBING-Rough 2/1/2022 Not Ready for Inspection RICHARD DOCKUS
Pre-Inspection 2/1/2022 Approved RICHARD DOCKUS
Wood Frame 2/1/2022 Corrections Issued RICHARD DOCKUS
BUILDING-Rough-Frame 2/4/2022 Partial Approval RICHARD DOCKUS
Excavation/Setback/Form/Re-Bar 2/4/2022 Approved RICHARD DOCKUS
Green Building Rough 2/4/2022 Not Ready for Inspection RICHARD DOCKUS
Floor/Roof Diaphrgm/Shear Wall 2/7/2022 Partial Approval KRISTEN CAUSEY
Floor/Roof Diaphrgm/Shear Wall 2/18/2022 Not Ready for Inspection RICHARD DOCKUS
ELECTRICAL-Rough 2/24/2022 Not Ready for Inspection RICHARD DOCKUS
Floor/Roof Diaphrgm/Shear Wall 2/24/2022 Partial Approval RICHARD DOCKUS
HVAC-Rough 2/24/2022 Not Ready for Inspection RICHARD DOCKUS
PLUMBING-Rough 2/24/2022 Not Ready for Inspection RICHARD DOCKUS
ELECTRICAL-Rough 3/1/2022 Approved RICHARD DOCKUS
HVAC-Rough 3/1/2022 Approved RICHARD DOCKUS
PLUMBING-Rough 3/1/2022 Approved RICHARD DOCKUS
BUILDING-Rough-Frame 3/8/2022 Not Ready for Inspection ALAN MORELOS
Green Building Rough 3/8/2022 Not Ready for Inspection ALAN MORELOS
Insulation 3/8/2022 Not Ready for Inspection ALAN MORELOS
Insulation 3/11/2022 No Access for Inspection ALAN MORELOS
Insulation 3/16/2022 Not Ready for Inspection ALAN MORELOS
Special/Order Compliance 3/17/2022 No Access for Inspection MICHAEL TEMPLE
Insulation 3/22/2022 Corrections Issued MICHAEL TEMPLE
Interior/Exterior Lathing 3/29/2022 Not Ready for Inspection DAVID MATSON
BUILDING-Rough-Frame 4/7/2022 Not Ready for Inspection RICHARD DOCKUS
Green Building Rough 4/7/2022 Not Ready for Inspection RICHARD DOCKUS
Insulation 4/7/2022 Not Ready for Inspection RICHARD DOCKUS
Interior/Exterior Lathing 4/7/2022 Not Ready for Inspection RICHARD DOCKUS
BUILDING-Rough-Frame 4/14/2022 Not Ready for Inspection RICHARD DOCKUS
Green Building Rough 4/14/2022 Approved RICHARD DOCKUS
Insulation 4/14/2022 Not Ready for Inspection RICHARD DOCKUS
Interior/Exterior Lathing 4/14/2022 Not Ready for Inspection RICHARD DOCKUS
BUILDING-Rough-Frame 4/26/2022 Not Ready for Inspection JENNIFER RABUCHIN
HVAC-Rough 4/26/2022 Corrections Issued JENNIFER RABUCHIN
PLUMBING-Rough 4/26/2022 Corrections Issued JENNIFER RABUCHIN
BUILDING-Rough-Frame 5/2/2022 Not Ready for Inspection RICHARD DOCKUS
BUILDING-Rough-Frame 5/6/2022 Not Ready for Inspection RICHARD DOCKUS
BUILDING-Rough-Frame 5/10/2022 Approved ALAN MORELOS
Floor/Roof Diaphrgm/Shear Wall 5/10/2022 Approved ALAN MORELOS
Interior/Exterior Lathing 5/13/2022 Corrections Issued DEANDRE HOFFMAN
Insulation 5/17/2022 Corrections Issued RICHARD DOCKUS
Insulation 5/23/2022 Approved ALAN MORELOS
Interior/Exterior Lathing 5/23/2022 Partial Approval ALAN MORELOS
Drywall Nailing 5/31/2022 Partial Approval DEANDRE HOFFMAN
Drywall Nailing 9/1/2022 Approved RICHARD DOCKUS
ELECTRICAL-Final 9/12/2022 Corrections Issued ROBERT GOLD
Final 9/12/2022 Not Ready for Inspection ROBERT GOLD
Green Building Final 9/12/2022 Approved ROBERT GOLD
SGSOV-Seismic Gas S/O Valve 9/12/2022 SGSOV Approved ROBERT GOLD
ELECTRICAL-Final 9/14/2022 Approved ALAN MORELOS
Final 9/14/2022 OK to Issue CofO ALAN MORELOS
Final 9/14/2022 Off-Hour Fees Due
HVAC-Final 9/14/2022 Approved ALAN MORELOS
PLUMBING-Final 9/14/2022 Approved ALAN MORELOS
Smoke Detectors 9/14/2022 Approved ALAN MORELOS
Smoke Detectors 9/14/2022 Off-Hour Fees Due