2500 N GRIFFITH PARK BLVD 90039
Certificate Information: 2500 N GRIFFITH PARK BLVD 90039
- Application / Permit
- 21014-10000-06268
- Plan Check / Job No.
- B21LA23515
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 2 STORY ADDITION AND ALTERATION TO AN (E) SFD W/ATTACHED GARAGE (GRADING & RETAINING WALL PERMITS TO BE UNDER SEPERATE APPLICATION/SUBMITTAL)
- Permit Issued
- Issued on 5/27/2022
- Issuing Office
- Metro
- Current Status
- Issued on 5/27/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/16/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 1/13/2022 | ADRIANA LOPEZ |
| Corrections Issued | 1/19/2022 | ADRIANA LOPEZ |
| Quality Review Completed | 1/19/2022 | KEN GILL |
| Applicant returned to address corrections | 4/6/2022 | ADRIANA LOPEZ |
| Plan Check Approved | 4/19/2022 | ADRIANA LOPEZ |
| Building Plans Picked Up | 4/29/2022 | APPLICANT |
| Issued | 5/27/2022 | APPLICANT |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 2/15/2022 | CINDY QI |
| BHO/Hillside ordinance | Cleared | 2/15/2022 | CINDY QI |
| BHO/Hillside ordinance | Cleared | 2/15/2022 | CINDY QI |
| BHO/Hillside ordinance | Cleared | 2/15/2022 | CINDY QI |
| BHO/Hillside ordinance | Cleared | 2/15/2022 | CINDY QI |
| Sewer availability | Cleared | 2/15/2022 | CINDY QI |
| Eng Process Fee Ord 176,300 | Cleared | 2/16/2022 | CINDY QI |
| Low Impact Development | Cleared | 2/18/2022 | CHRIS VONG |
| Roof/Waste drainage to street | Cleared | 2/25/2022 | WALLIE JONG |
| GPI Written Notices | Cleared | 4/6/2022 | ADRIANA LOPEZ |
| Grading Pre-Inspection | Cleared | 4/6/2022 | ROBERT HUGHES |
Contact Information
| Contractor | Radd Construction; Lic. No.: 922522-B | 5736 N LAS VIRGENES APT #226 CALABASAS, CA 91302 |
| Engineer | Simonian,, Ara; Lic. No.: C37208 | 314 E BROADWAY STE A GLENDALE, CA 91205 |
Inspector Information
| ENRIQUE MIRELES, (213) 202-3438 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 7/5/2022 | Approved | JOSEPH MCGARRY |
| Deputy Drilled-In Anchors | 7/7/2022 | Approved | JOSEPH MCGARRY |
| Excavation/Setback/Form/Re-Bar | 7/7/2022 | Partial Approval | JOSEPH MCGARRY |
| Deputy Drilled-In Anchors | 7/8/2022 | Approved | JOSEPH MCGARRY |
| Excavation/Setback/Form/Re-Bar | 7/11/2022 | Partial Approval | JOSEPH MCGARRY |
| Special/Order Compliance | 7/11/2022 | Partial Approval | JOSEPH MCGARRY |
| PLUMBING-Rough | 7/19/2022 | Partial Approval | JOSEPH MCGARRY |
| Floor/Roof Diaphrgm/Shear Wall | 8/17/2022 | Not Ready for Inspection | JOSEPH MCGARRY |
| BUILDING-Rough-Frame | 8/18/2022 | Partial Approval | JOSEPH MCGARRY |
| Deputy Wood Construction | 8/18/2022 | Approved | JOSEPH MCGARRY |
| ELECTRICAL-Rough | 8/18/2022 | Approved | JOSEPH MCGARRY |
| HVAC-Rough | 8/18/2022 | Approved | JOSEPH MCGARRY |
| PLUMBING-Rough | 8/18/2022 | Approved | JOSEPH MCGARRY |
| Shower Pan | 8/22/2022 | Approved | JOSEPH MCGARRY |
| Insulation | 8/23/2022 | Approved | JOSEPH MCGARRY |
| Footing/Foundation/Slab | 8/25/2022 | Partial Approval | JOSEPH MCGARRY |
| Interior/Exterior Lathing | 8/25/2022 | Partial Approval | JOSEPH MCGARRY |
| Drywall Nailing | 8/30/2022 | Conditional Approval | JOSEPH MCGARRY |
| Footing/Foundation/Slab | 8/30/2022 | Approved | JOSEPH MCGARRY |
| BUILDING-Rough-Frame | 10/26/2022 | Approved | JOSEPH MCGARRY |
| FLOOD-Proofing Certificate | 10/26/2022 | Approved | JOSEPH MCGARRY |
| Green Building Rough | 10/26/2022 | Approved | JOSEPH MCGARRY |
| Interior/Exterior Lathing | 10/26/2022 | Approved | JOSEPH MCGARRY |
| Drywall Nailing | 12/20/2022 | Approved | JOSEPH MCGARRY |
| Final | 12/20/2022 | Corrections Issued | JOSEPH MCGARRY |
| Green Building Final | 12/20/2022 | Approved | JOSEPH MCGARRY |
| SGSOV-Seismic Gas S/O Valve | 12/20/2022 | SGSOV Approved | JOSEPH MCGARRY |
| Smoke Detectors | 12/20/2022 | Not Ready for Inspection | JOSEPH MCGARRY |
| Final | 12/19/2024 | Corrections Issued | ENRIQUE MIRELES |
| Smoke Detectors | 12/19/2024 | Approved | ENRIQUE MIRELES |