1423 S MEADOWBROOK AVE 90019

Certificate Information: 1423 S MEADOWBROOK AVE 90019

Application / Permit
21014-10000-04317
Plan Check / Job No.
B21LA15922
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(2) Duplex
Work Description
PROPOSED 1-STORY MASTER BEDROOM AND BATHROOM ADDITION TO REAR OF EXISTING DUPLEX.
Permit Issued
Issued on 2/27/2022
Issuing Office
Current Status
CofO Issued on 3/19/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/30/2021 APPLICANT
Assigned to Plan Check Engineer 9/2/2021 LAWRENCE QUIRANTE
Corrections Issued 9/4/2021 LAWRENCE QUIRANTE
Applicant returned to address corrections 1/13/2022 LAWRENCE QUIRANTE
Plan Check Approved 2/23/2022 FERNANDO FLORES
Issued 2/27/2022 APPLICANT
Building Plans Picked Up 3/1/2022 APPLICANT
CofO in Progress 8/23/2022 JOSE AVILA
Permit Finaled 3/19/2023 DEROLD HAUFF
CofO Issued 3/19/2023 DEROLD HAUFF
Permit Finaled 3/19/2023 DEROLD HAUFF

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 11/24/2021 CINDY QI
Sewer availability Cleared 11/24/2021 CINDY QI
Eng Process Fee Ord 176,300 Cleared 11/30/2021 CINDY QI
Tenant Habitability Plan Cleared 2/15/2022 RICARDO BOHORQUEZ

Contact Information

Contractor Sanchez J P Construction Co; Lic. No.: 1062507-B 406 E 46TH ST      LOS ANGELES, CA 90011
Engineer Oseguera,, Jorge; Lic. No.: C86337 P O BOX 4835      VENTURA, CA 93007

Inspector Information

DAVID WILLIAMS, (213) 202-3126 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 5/6/2022 Approved JOSE AVILA
Deputy Drilled-In Anchors 5/9/2022 Conditional Approval RUBEN SALAS
Footing/Foundation/Slab 5/9/2022 Approved STUART CHAPMAN
Insulation 5/18/2022 Approved JOSE AVILA
PLUMBING-Rough 5/18/2022 Partial Approval JOSE AVILA
Wood Frame 5/18/2022 Partial Approval JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 5/23/2022 Approved JOSE AVILA
BUILDING-Rough-Frame 6/1/2022 Not Ready for Inspection JOSE AVILA
ELECTRICAL-Rough 6/1/2022 Approved JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 6/1/2022 Approved JOSE AVILA
Green Building Rough 6/1/2022 Not Ready for Inspection JOSE AVILA
HVAC-Rough 6/1/2022 Partial Approval JOSE AVILA
Insulation 6/1/2022 Not Ready for Inspection JOSE AVILA
PLUMBING-Rough 6/1/2022 Corrections Issued JOSE AVILA
Wood Frame 6/1/2022 Not Ready for Inspection JOSE AVILA
BUILDING-Rough-Frame 6/7/2022 Approved JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 6/7/2022 Partial Approval JOSE AVILA
Green Building Rough 6/7/2022 Approved JOSE AVILA
PLUMBING-Rough 6/7/2022 Partial Approval JOSE AVILA
Insulation 6/8/2022 Approved JOSE AVILA
Interior/Exterior Lathing 6/8/2022 Approved JOSE AVILA
Drywall Nailing 6/14/2022 Approved KATHRYN BUTTERWORTH
Interior/Exterior Lathing 6/14/2022 Approved KATHRYN BUTTERWORTH
Gas Test 7/26/2022 Approved JOSE AVILA
Smoke Detectors 7/26/2022 Approved JOSE AVILA
ELECTRICAL-Final 8/10/2022 Approved JOSE AVILA
Green Building Final 8/10/2022 Approved JOSE AVILA
HVAC-Final 8/10/2022 Conditional Approval JOSE AVILA
Final 8/12/2022 Corrections Issued JOSE AVILA
HVAC-Final 8/12/2022 Approved JOSE AVILA
PLUMBING-Final 8/12/2022 Approved JOSE AVILA
SGSOV-Seismic Gas S/O Valve 8/12/2022 SGSOV Approved JOSE AVILA
ELECTRICAL-Final 8/16/2022 Approved JOSE AVILA
Final 8/16/2022 Corrections Issued JOSE AVILA
HVAC-Final 8/16/2022 Conditional Approval JOSE AVILA
PLUMBING-Final 8/16/2022 Approved JOSE AVILA
ELECTRICAL-Final 8/22/2022 Approved JOSE AVILA
Final 8/22/2022 OK to Issue CofO JOSE AVILA
HVAC-Final 8/22/2022 Approved JOSE AVILA
PLUMBING-Final 8/22/2022 Approved JOSE AVILA