2928 S EDGEHILL DR 90018

Certificate Information: 2928 S EDGEHILL DR 90018

Application / Permit
21014-10000-04275
Plan Check / Job No.
B21LA15771
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PROPOSED BEDROOM / BATHROOM / KITCHEN / DECK ADDITION TO REAR OF (E) SFD.
Permit Issued
Issued on 12/16/2021
Issuing Office
Current Status
CofO Issued on 7/31/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/23/2021 APPLICANT
Assigned to Plan Check Engineer 8/27/2021 LAWRENCE QUIRANTE
Corrections Issued 8/28/2021 LAWRENCE QUIRANTE
Issued 12/16/2021 APPLICANT
Building Plans Picked Up 12/22/2021 APPLICANT
CofO in Progress 5/8/2023 CALEB MEISTER
No Progress 5/15/2023 CALEB MEISTER
CofO Issued 7/31/2024 DEROLD HAUFF
Permit Finaled 7/31/2024 DEROLD HAUFF

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 9/17/2021 THOMAS LANG
Sewer availability Cleared 9/17/2021 THOMAS LANG
Eng Process Fee Ord 176,300 Cleared 9/21/2021 THOMAS LANG

Contact Information

Architect Ehdaie,, Behrouze; Lic. No.: C14284 12 LAGO SUD      IRVINE, CA 92612
Contractor Maier Construction Inc; Lic. No.: 981150-B 736 SOUTH CAMINO GRANDE      ANAHEIM, CA 92807
Engineer Manshadi,, Farhad; Lic. No.: C36840 ESI FME INC 1800 E 16TH ST      SANTA ANA, CA 92701

Inspector Information

JUSTIN HAWLEY, (213) 202-3432 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 1/6/2022 Partial Inspection THOMAS LOGRASSO
Deputy Drilled-In Anchors 1/18/2022 Approved STUART CHAPMAN
Footing/Foundation/Slab 1/21/2022 Approved ALFREDO BALANDRA
Floor/Roof Diaphrgm/Shear Wall 2/7/2022 Partial Approval STUART CHAPMAN
Insulation 2/7/2022 Partial Approval STUART CHAPMAN
PLUMBING-Rough 2/7/2022 Partial Approval STUART CHAPMAN
Floor/Roof Diaphrgm/Shear Wall 3/3/2022 Corrections Issued AMY COLIN
Deputy Wood Construction 3/10/2022 Approved STUART CHAPMAN
Floor/Roof Diaphrgm/Shear Wall 3/10/2022 Partial Approval STUART CHAPMAN
Drywall Nailing 3/16/2022 Partial Approval STUART CHAPMAN
BUILDING-Rough-Frame 3/21/2022 Corrections Issued STUART CHAPMAN
ELECTRICAL-Rough 3/21/2022 Approved STUART CHAPMAN
HVAC-Rough 3/21/2022 Corrections Issued STUART CHAPMAN
PLUMBING-Rough 3/21/2022 Approved STUART CHAPMAN
Interior/Exterior Lathing 3/30/2022 Corrections Issued STUART CHAPMAN
Insulation 3/31/2022 Approved STUART CHAPMAN
Interior/Exterior Lathing 3/31/2022 Partial Approval STUART CHAPMAN
Interior/Exterior Lathing 4/4/2022 Not Ready for Inspection STUART CHAPMAN
Floor/Roof Diaphrgm/Shear Wall 4/20/2022 Not Ready for Inspection STUART CHAPMAN
Drywall Nailing 4/22/2022 Approved STUART CHAPMAN
Service/Power Release 5/9/2022 Approved STUART CHAPMAN
Interior/Exterior Lathing 5/31/2022 Approved STUART CHAPMAN
Shower Pan 5/31/2022 Approved STUART CHAPMAN
SGSOV-Seismic Gas S/O Valve 12/7/2022 SGSOV Not Ready STUART CHAPMAN
BUILDING-Rough-Frame 12/13/2022 Not Ready for Inspection CALEB MEISTER
Final 12/13/2022 Not Ready for Inspection CALEB MEISTER
Green Building Final 12/13/2022 Not Ready for Inspection CALEB MEISTER
Green Building Rough 12/13/2022 Not Ready for Inspection CALEB MEISTER
SGSOV-Seismic Gas S/O Valve 12/13/2022 SGSOV Not Ready CALEB MEISTER
Smoke Detectors 12/13/2022 Approved CALEB MEISTER
BUILDING-Rough-Frame 3/17/2023 Approved STUART CHAPMAN
Final 3/17/2023 Corrections Issued STUART CHAPMAN
Green Building Final 3/17/2023 Approved STUART CHAPMAN
Green Building Rough 3/17/2023 Approved STUART CHAPMAN
SGSOV-Seismic Gas S/O Valve 3/17/2023 SGSOV Approved STUART CHAPMAN
Final 4/6/2023 No Access for Inspection CALEB MEISTER
Final 4/19/2023 No Access for Inspection MICHAEL LEWIS
Final 5/4/2023 OK to Issue CofO CALEB MEISTER