2239 1/2 W BRIER AVE 90039
Certificate Information: 2239 1/2 W BRIER AVE 90039
- Application / Permit
- 21014-10000-03960
- Plan Check / Job No.
- B21LA14622
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- Convert existing detached garage to A.D.U. and 2nd story addition per LAMC 12.22.A.33(c) & (d). the LID clearance has been deferred. approval for LID requirement shall be obtained from LASAN prior to the issuance of certificate of occupancy
- Permit Issued
- Issued on 1/25/2022
- Issuing Office
- Current Status
- CofO Issued on 3/4/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/9/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 8/26/2021 | ARSALAN SHABESTARI |
| Corrections Issued | 8/28/2021 | ARSALAN SHABESTARI |
| Quality Review Completed | 9/11/2021 | YOUNG KIM |
| Applicant returned to address corrections | 1/4/2022 | ARSALAN SHABESTARI |
| Plan Check Approved | 1/17/2022 | ARSALAN SHABESTARI |
| Issued | 1/25/2022 | APPLICANT |
| CofO in Progress | 3/2/2023 | THOMAS LOGRASSO |
| Permit Finaled | 3/4/2023 | DEROLD HAUFF |
| CofO Issued | 3/4/2023 | DEROLD HAUFF |
| Permit Finaled | 3/4/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 9/10/2021 | STEVE MELGAR |
| BHO/Hillside ordinance | Cleared | 9/10/2021 | STEVE MELGAR |
| Eng Process Fee Ord 176,300 | Cleared | 9/13/2021 | STEVE MELGAR |
| Sewer availability | Cleared | 9/16/2021 | STEVE MELGAR |
| GPI Written Notices | Cleared | 10/4/2021 | ALEXANDER HELFER |
| Roof/Waste drainage to street | Cleared | 12/22/2021 | AMAAN MALIK |
| Grading Pre-Inspection | Cleared | 1/17/2022 | ARSALAN SHABESTARI |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| HAMIK HARTOUNIAN, (213) 202-3275 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 2/8/2022 | Partial Inspection | THOMAS LOGRASSO |
| Excavation/Setback/Form/Re-Bar | 2/28/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 2/28/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Excavation/Setback/Form/Re-Bar | 3/8/2022 | Approved | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 3/8/2022 | Approved | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 3/15/2022 | Conditional Approval | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 3/17/2022 | Partial Approval | THOMAS LOGRASSO |
| PLUMBING-Rough | 3/22/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Insulation | 3/25/2022 | Partial Approval | THOMAS LOGRASSO |
| PLUMBING-Rough | 3/25/2022 | Corrections Issued | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 3/29/2022 | Partial Approval | THOMAS LOGRASSO |
| PLUMBING-Rough | 3/30/2022 | Partial Inspection | THOMAS LOGRASSO |
| Underground Mechanical | 4/4/2022 | Partial Approval | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 4/8/2022 | Corrections Issued | THOMAS LOGRASSO |
| Sewer | 4/11/2022 | Partial Approval | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 4/15/2022 | Corrections Issued | THOMAS LOGRASSO |
| Deputy Drilled-In Anchors | 4/18/2022 | Conditional Approval | THOMAS LOGRASSO |
| ELECTRICAL-Rough | 5/12/2022 | Corrections Issued | THOMAS LOGRASSO |
| HVAC-Rough | 5/12/2022 | Corrections Issued | THOMAS LOGRASSO |
| PLUMBING-Rough | 5/12/2022 | Corrections Issued | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 5/19/2022 | Corrections Issued | THOMAS LOGRASSO |
| ELECTRICAL-Rough | 5/19/2022 | Approved | THOMAS LOGRASSO |
| HVAC-Rough | 5/19/2022 | Approved | THOMAS LOGRASSO |
| PLUMBING-Rough | 5/19/2022 | Partial Approval | THOMAS LOGRASSO |
| Verify Sprinkler Sign Off | 5/19/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 5/25/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Special/Order Compliance | 5/25/2022 | Partial Inspection | RYAN SALAZAR |
| BUILDING-Rough-Frame | 6/3/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Verify Sprinkler Sign Off | 6/3/2022 | Approved | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 6/6/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Shower Pan | 6/6/2022 | Partial Approval | THOMAS LOGRASSO |
| Underground Mechanical | 6/6/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 6/8/2022 | Partial Approval | THOMAS LOGRASSO |
| Shower Pan | 6/8/2022 | Approved | THOMAS LOGRASSO |
| Underground Mechanical | 6/8/2022 | Partial Approval | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 6/9/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Shower Pan | 6/9/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Underground Mechanical | 6/9/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Interior/Exterior Lathing | 6/23/2022 | Partial Approval | HAMIK HARTOUNIAN |
| Drywall Nailing | 6/27/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Interior/Exterior Lathing | 6/27/2022 | Partial Approval | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 8/30/2022 | Approved | THOMAS LOGRASSO |
| ELECTRICAL-Final | 8/30/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| PLUMBING-Final | 8/30/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| ELECTRICAL-Final | 9/7/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| HVAC-Final | 9/7/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| ELECTRICAL-Final | 9/19/2022 | Not Ready for Inspection | STUART CHAPMAN |
| Final | 9/19/2022 | Corrections Issued | STUART CHAPMAN |
| HVAC-Final | 9/19/2022 | Not Ready for Inspection | STUART CHAPMAN |
| ELECTRICAL-Final | 9/28/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Final | 9/28/2022 | Corrections Issued | THOMAS LOGRASSO |
| HVAC-Final | 9/28/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| SGSOV-Seismic Gas S/O Valve | 9/28/2022 | SGSOV Not Ready | THOMAS LOGRASSO |
| Smoke Detectors | 9/28/2022 | Approved | THOMAS LOGRASSO |
| Final | 10/5/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| PLUMBING-Final | 10/5/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| SGSOV-Seismic Gas S/O Valve | 10/5/2022 | SGSOV Not Ready | THOMAS LOGRASSO |
| Final | 10/31/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| SGSOV-Seismic Gas S/O Valve | 10/31/2022 | SGSOV Approved | THOMAS LOGRASSO |
| Service/Power Release | 10/31/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Service/Power Release | 2/23/2023 | Approved | DONALD CRICHLOW |
| Final | 3/2/2023 | OK to Issue CofO | THOMAS LOGRASSO |