7998 N CANTALOUPE AVE 91402
Certificate Information: 7998 N CANTALOUPE AVE 91402
- Application / Permit
- 21014-10000-02110
- Plan Check / Job No.
- B21LA08031
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- ADDITION AND CONVERT TO (E) 2 CAR GARAGE TO ADU. GCS
- Permit Issued
- Issued on 7/28/2021
- Issuing Office
- Current Status
- CofO Issued on 1/22/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/30/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 4/30/2021 | HERNAN ARREOLA |
| Corrections Issued | 4/30/2021 | HERNAN ARREOLA |
| Applicant returned to address corrections | 5/10/2021 | HERNAN ARREOLA |
| Plan Check Approved | 7/16/2021 | HERNAN ARREOLA |
| Issued | 7/28/2021 | APPLICANT |
| CofO in Progress | 12/8/2021 | GREGG CUMMINGS |
| Permit Finaled | 1/22/2022 | MICHAEL SMITH |
| CofO Issued | 1/22/2022 | MICHAEL SMITH |
| Permit Finaled | 1/22/2022 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 5/3/2021 | JOHN TRIANTAFYLLOS |
| Eng Process Fee Ord 176,300 | Cleared | 5/3/2021 | JOHN TRIANTAFYLLOS |
| Roof/Waste drainage to street | Cleared | 5/3/2021 | JOHN TRIANTAFYLLOS |
| Sewer availability | Cleared | 5/3/2021 | JOHN TRIANTAFYLLOS |
| Construction near power lines | Cleared | 7/12/2021 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/24/2021 | Approved | GREGG CUMMINGS |
| Sewer | 8/27/2021 | Partial Inspection | GREGG CUMMINGS |
| Footing/Foundation/Slab | 8/31/2021 | Partial Approval | GREGG CUMMINGS |
| PLUMBING-Rough | 8/31/2021 | Corrections Issued | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 9/2/2021 | Approved | GREGG CUMMINGS |
| Footing/Foundation/Slab | 9/2/2021 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 9/2/2021 | Partial Approval | GREGG CUMMINGS |
| Sewer | 9/2/2021 | Approved | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 9/13/2021 | Corrections Issued | JOHN HAYES |
| ELECTRICAL-Rough | 9/13/2021 | Not Ready for Inspection | JOHN HAYES |
| ELECTRICAL-Rough | 9/20/2021 | Approved | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 9/20/2021 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 9/20/2021 | Not Ready for Inspection | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 9/22/2021 | Approved | GREGG CUMMINGS |
| HVAC-Rough | 9/22/2021 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 9/22/2021 | Approved | GREGG CUMMINGS |
| Green Building Rough | 9/24/2021 | Approved | GREGG CUMMINGS |
| Insulation | 9/24/2021 | Approved | GREGG CUMMINGS |
| Interior/Exterior Lathing | 9/24/2021 | Partial Approval | GREGG CUMMINGS |
| Drywall Nailing | 9/28/2021 | Approved | WILLIAM KUEHN |
| Gas Test | 10/12/2021 | Approved | WILLIAM KUEHN |
| Final | 11/19/2021 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 11/19/2021 | Not Ready for Inspection | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 11/19/2021 | SGSOV Not Ready | GREGG CUMMINGS |
| Smoke Detectors | 11/19/2021 | Not Ready for Inspection | GREGG CUMMINGS |
| Final | 12/1/2021 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 12/1/2021 | Not Ready for Inspection | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 12/1/2021 | SGSOV Approved | GREGG CUMMINGS |
| Smoke Detectors | 12/1/2021 | Not Ready for Inspection | GREGG CUMMINGS |
| ELECTRICAL-Final | 12/8/2021 | Approved | GREGG CUMMINGS |
| Final | 12/8/2021 | OK to Issue CofO | GREGG CUMMINGS |
| Green Building Final | 12/8/2021 | Approved | GREGG CUMMINGS |
| HVAC-Final | 12/8/2021 | Approved | GREGG CUMMINGS |
| PLUMBING-Final | 12/8/2021 | Approved | GREGG CUMMINGS |
| Smoke Detectors | 12/8/2021 | Approved | GREGG CUMMINGS |