1412-1412 1/2 N MOHAWK ST 90026
Certificate Information: 1412-1412 1/2 N MOHAWK ST 90026
- Application / Permit
- 21014-10000-01451
- Plan Check / Job No.
- B21LA05498
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePLAN. NEW ATTACHED ACCESSORY DWELLING UNIT ADDITION AT REAR OF (E) FRONT SINGLE FAMILY DWELLING PER LAMC 12.22 A.33(c) and (e)
- Permit Issued
- Issued on 10/25/2021
- Issuing Office
- Current Status
- CofO Issued on 10/12/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/24/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 3/29/2021 | KEVIN MORALES |
| Corrections Issued | 3/29/2021 | KEVIN MORALES |
| Plan Check Approved | 8/30/2021 | KEVIN MORALES |
| Issued | 10/25/2021 | APPLICANT |
| CofO in Progress | 8/31/2022 | THOMAS LOGRASSO |
| CofO Issued | 10/12/2022 | DEROLD HAUFF |
| Permit Finaled | 10/12/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 4/5/2021 | RENZ SORIANO |
| Sewer availability | Cleared | 4/5/2021 | RENZ SORIANO |
| Address approval | Cleared | 4/16/2021 | RENZ SORIANO |
| Hydrant and Access approval | Cleared | 5/22/2021 | ROBERT DUFF |
| Low Impact Development | Cleared | 6/24/2021 | ANDRES COVARRUBIAS |
| Roof/Waste drainage to street | Cleared | 8/2/2021 | RENZ SORIANO |
| GPI Written Notices | Cleared | 8/30/2021 | KEVIN MORALES |
| Grading Pre-Inspection | Cleared | 8/30/2021 | KEVIN MORALES |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Mayorga,, Jose Aguinaldo; Lic. No.: C50322 | 20457 OREY PL WINNETKA, CA 91306 |
Inspector Information
| HAMIK HARTOUNIAN, (213) 202-3275 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 12/27/2021 | Conditional Approval | THOMAS LOGRASSO |
| PLUMBING-Rough | 1/6/2022 | Corrections Issued | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 1/21/2022 | Corrections Issued | THOMAS LOGRASSO |
| PLUMBING-Rough | 1/21/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 1/31/2022 | Partial Approval | THOMAS LOGRASSO |
| PLUMBING-Rough | 1/31/2022 | Partial Approval | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 3/7/2022 | Corrections Issued | THOMAS LOGRASSO |
| Floor/Roof Diaphrgm/Shear Wall | 3/9/2022 | Partial Approval | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 3/23/2022 | Approved | THOMAS LOGRASSO |
| Interior/Exterior Lathing | 3/23/2022 | Approved | THOMAS LOGRASSO |
| Rough-Elec/Plmb/HVAC | 3/23/2022 | Approved | THOMAS LOGRASSO |
| Sewer | 3/23/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Insulation | 3/30/2022 | Partial Approval | THOMAS LOGRASSO |
| Drywall Nailing | 4/7/2022 | Corrections Issued | THOMAS LOGRASSO |
| Drywall Nailing | 4/13/2022 | Approved | HAMIK HARTOUNIAN |
| Sewer | 5/17/2022 | Approved | THOMAS LOGRASSO |
| Final | 6/7/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 6/7/2022 | Approved | THOMAS LOGRASSO |
| SGSOV-Seismic Gas S/O Valve | 6/7/2022 | SGSOV Not Ready | THOMAS LOGRASSO |
| Smoke Detectors | 6/7/2022 | Partial Inspection | THOMAS LOGRASSO |
| Final | 6/15/2022 | Corrections Issued | THOMAS LOGRASSO |
| Gas Test | 6/15/2022 | Approved | THOMAS LOGRASSO |
| SGSOV-Seismic Gas S/O Valve | 6/15/2022 | SGSOV Approved | THOMAS LOGRASSO |
| Smoke Detectors | 6/15/2022 | Approved | THOMAS LOGRASSO |
| Final | 8/19/2022 | Not Ready for Inspection | THOMAS LOGRASSO |
| Final | 8/30/2022 | OK to Issue CofO | THOMAS LOGRASSO |