10909 W MORRISON ST 1-10 91601

Certificate Information: 10909 W MORRISON ST 1-10 91601

Application / Permit
21014-10000-01162
Plan Check / Job No.
B21LA04461
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
ePlan CREATE TWO ATTACHED ACCESSORY DWELLING UNITS PER STATE LAW GCS 65852.2(e)(1)(C).
Permit Issued
Issued on 5/4/2022
Issuing Office
Current Status
CofO Issued on 5/4/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 3/24/2021 APPLICANT
Assigned to Plan Check Engineer 4/22/2021 MICHAEL LOPEZ
Corrections Issued 4/28/2021 MICHAEL LOPEZ
Quality Review Completed 5/4/2021 HERNAN ARREOLA
Applicant returned to address corrections 3/23/2022 MICHAEL LOPEZ
Applicant returned to address corrections 4/8/2022 MICHAEL LOPEZ
Plan Check Approved 5/3/2022 ARSALAN SHABESTARI
Issued 5/4/2022 APPLICANT
CofO in Progress 4/28/2023 ROBERT DAVIS
Permit Finaled 5/4/2023 JEFFREY DURAN
CofO Issued 5/4/2023 JEFFREY DURAN
Permit Finaled 5/4/2023 JEFFREY DURAN

Permit Application Clearance Information

Address approval Cleared 6/22/2021 DAGOVERTO GUERRERO
Sewer availability Cleared 6/22/2021 DAGOVERTO GUERRERO
Eng Process Fee Ord 176,300 Cleared 6/23/2021 DAGOVERTO GUERRERO
"Q" conditions Cleared 6/29/2021 RUBEN VASQUEZ
Tenant Habitability Plan Cleared 3/7/2022 MICHAEL SOTO
Green Code Cleared 4/10/2022 MICHAEL LOPEZ

Contact Information

Contractor Owner-Builder       ,
Engineer Schwartzberg,, Leo Joshua; Lic. No.: C51851 7547 SEDGEWICK CT      WEST HILLS, CA 91304

Inspector Information

JEFFREY FULTON, (818) 374-1132 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 6/1/2022 Approved ROBERT DAVIS
Deputy Drilled-In Anchors 9/21/2022 Conditional Approval ROBERT DAVIS
Footing/Foundation/Slab 9/22/2022 Approved ROBERT DAVIS
Structural Steel Frame 9/22/2022 Not Ready for Inspection ROBERT DAVIS
Green Building Rough 11/3/2022 Not Ready for Inspection ROBERT DAVIS
Wood Frame 11/3/2022 Partial Approval ROBERT DAVIS
Insulation 11/18/2022 Approved ROBERT DAVIS
Interior/Exterior Lathing 11/18/2022 Approved ROBERT DAVIS
Drywall Nailing 11/30/2022 Approved ROBERT DAVIS
Interior/Exterior Lathing 11/30/2022 Approved ROBERT DAVIS
Final 3/15/2023 Not Ready for Inspection ROBERT DAVIS
Green Building Final 3/15/2023 Approved ROBERT DAVIS
Green Building Rough 3/15/2023 Approved ROBERT DAVIS
SGSOV-Seismic Gas S/O Valve 3/15/2023 SGSOV Approved ROBERT DAVIS
Smoke Detectors 3/15/2023 Approved ROBERT DAVIS
Wood Frame 3/15/2023 Approved ROBERT DAVIS
Final 4/5/2023 Not Ready for Inspection ROBERT DAVIS
Final 4/28/2023 OK to Issue CofO ROBERT DAVIS