Work Description
ONE STORY ADDITION TO EXISTING ONE STORY RESIDENCE WITH AND INTERIOR REMODEL. ADDING A MASTER BEDROOM WITH WALK IN CLOSET AND MASTER BATHROOM REMODEL KITCHEN, ADD A BATHROOM, AND RELOCATE LAUNDRY ROOM.
Permit Issued
Issued on 5/27/2021
Issuing Office
Current Status
Issued on 5/27/2021
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 1/26/2021 APPLICANT
Assigned to Plan Check Engineer 3/3/2021 FARSHAD ALIMOHAMADI
Corrections Issued 3/3/2021 FARSHAD ALIMOHAMADI
Applicant returned to address corrections 5/15/2021 SAMUEL GONZALEZ
Plan Check Approved 5/27/2021 SAMUEL GONZALEZ
Issued 5/27/2021 APPLICANT
Building Plans Picked Up 6/3/2021 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 3/9/2021 JOHN TRIANTAFYLLOS
ZI Cleared 4/1/2021 ANACANY HURTADO
Low Impact Development Cleared 5/5/2021 MITESH PATEL
Roof/Waste drainage to street Cleared 5/6/2021 JOHN TRIANTAFYLLOS
Hold Cleared 7/12/2021 MARIA V VASQUEZ

Contact Information

Contractor Owner-Builder       ,
Engineer Melchor,, Oscar Elias; Lic. No.: C76828 21243 VENTURA BLVD SUITE 119      WOODLAND HILLS, CA 91364

Inspector Information

JAVIER RAMOS JR, (818) 374-1163 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 6/15/2021 Corrections Issued THOMAS FINNILA
Footing/Foundation/Slab 6/22/2021 Approved THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 6/28/2021 Partial Approval THOMAS FINNILA
BUILDING-Rough-Frame 7/1/2021 Partial Approval THOMAS FINNILA
MERV13>=Rough 7/1/2021 Not Ready for Inspection THOMAS FINNILA
ELECTRICAL-Rough 7/26/2021 Partial Inspection THOMAS FINNILA
HVAC-Rough 7/26/2021 Partial Approval THOMAS FINNILA
PLUMBING-Rough 7/26/2021 Partial Approval THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 7/29/2021 Approved ARAM AVEDISIAN
Green Building Rough 7/29/2021 No Access for Inspection VINCENT HANLEY
MERV13>=Rough 7/29/2021 Approved ARAM AVEDISIAN
Rough-Elec/Plmb/HVAC 7/29/2021 Approved ARAM AVEDISIAN
Interior/Exterior Lathing 8/3/2021 Partial Approval JUSTIN HAWLEY
Insulation 8/5/2021 Approved AMY COLIN
Shower Pan 8/9/2021 Corrections Issued CHRISTOPHER DELLEFIELD
Interior/Exterior Lathing 8/12/2021 Corrections Issued THOMAS FINNILA
Drywall Nailing 8/16/2021 Not Ready for Inspection LILIANA PORTILLO
Shower Pan 8/16/2021 Approved LILIANA PORTILLO
BUILDING-Rough-Frame 8/23/2021 Approved MICHAEL PELHAM
Drywall Nailing 8/23/2021 Approved MICHAEL PELHAM
Green Building Rough 8/23/2021 Approved MICHAEL PELHAM
PLUMBING-Final 8/23/2021 Corrections Issued THOMAS FINNILA
Gas Test 8/24/2021 Approved LILIANA PORTILLO
Final 11/12/2021 Partial Inspection THOMAS FINNILA
Green Building Final 11/12/2021 Corrections Issued THOMAS FINNILA
MERV13>=Final 11/12/2021 Approved THOMAS FINNILA
SGSOV-Seismic Gas S/O Valve 11/12/2021 SGSOV Approved THOMAS FINNILA
Smoke Detectors 11/12/2021 Corrections Issued THOMAS FINNILA
Final 12/3/2021 Partial Inspection THOMAS FINNILA
Green Building Final 12/3/2021 Corrections Issued THOMAS FINNILA
Smoke Detectors 12/3/2021 Conditional Approval THOMAS FINNILA
Final 12/15/2021 Corrections Issued THOMAS FINNILA
Green Building Final 12/15/2021 Approved THOMAS FINNILA
Smoke Detectors 12/15/2021 Approved THOMAS FINNILA