12725 W SUNSET BLVD 90049

Certificate Information: 12725 W SUNSET BLVD 90049

Application / Permit
21010-30000-06699
Plan Check / Job No.
B21WL05738
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(23) Accessory Living Quarters
Work Description
(N) 1-story ALQ w/ covered patio. Fully equipped w/fire sprinklers NFPA 13R
Permit Issued
Issued on 8/19/2022
Issuing Office
West Los Angeles
Current Status
CofO Issued on 3/16/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/23/2021 APPLICANT
Assigned to Plan Check Engineer 1/7/2022 ALFREDO JARA
Corrections Issued 1/11/2022 ALFREDO JARA
Quality Review Completed 2/7/2022 CHIHARU SUZUKI
Plan Check Approved 8/10/2022 ALFREDO JARA
Issued 8/19/2022 APPLICANT
CofO in Progress 3/3/2026 KEVIN SARGSYAN
Permit Finaled 3/16/2026 RICHARD STEINBACH
CofO Issued 3/16/2026 RICHARD STEINBACH
Permit Finaled 3/16/2026 RICHARD STEINBACH

Permit Application Clearance Information

Sewer availability Cleared 2/28/2022 DINAH GARIN
Eng Process Fee Ord 176,300 Cleared 4/15/2022 DINAH GARIN
Hydrant and Access approval Cleared 5/4/2022 KURT CORRAL
Low Impact Development Cleared 5/4/2022 KHAING AYE
Roof/Waste drainage to street Cleared 5/31/2022 DINAH GARIN
GPI Written Notices Cleared 6/7/2022 ALFREDO JARA
Grading Pre-Inspection Cleared 6/7/2022 ALFREDO JARA

Contact Information

Architect Rios,, Mark William; Lic. No.: C15744 3101 W EXPOSITION PLACE      LOS ANGELES, CA 90018
Contractor Fort Hill Construction; Lic. No.: 414092-B 12711 VENTURA BLVD STE 390      STUDIO CITY, CA 91604
Engineer Kwan,, Denny Chi-Ho; Lic. No.: S4887 5638 NEWFIELDS LN      DUBLIN, CA 94568
Engineer White,, William Michael; Lic. No.: C62111 19619 MATHILDE LN      SAUGUS, CA 91350

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 8/29/2022 Approved JUAN VALENZUELA
Footing/Foundation/Slab 11/1/2023 Approved ARAM AVEDISIAN
Gas Test 12/13/2023 Partial Approval KEVIN SARGSYAN
Sewer 12/13/2023 Approved KEVIN SARGSYAN
Floor/Roof Diaphrgm/Shear Wall 3/21/2024 Partial Approval KEVIN SARGSYAN
Floor/Roof Diaphrgm/Shear Wall 3/27/2024 Partial Approval KEVIN SARGSYAN
PLUMBING-Rough 4/29/2024 Corrections Issued KEVIN SARGSYAN
Floor/Roof Diaphrgm/Shear Wall 5/10/2024 Partial Approval KEVIN SARGSYAN
Drywall Nailing 5/23/2024 Partial Approval EVAN COOPER
Green Building Rough 5/23/2024 Not Ready for Inspection EVAN COOPER
Interior/Exterior Lathing 5/28/2024 Partial Approval KENNETH NAGLE
HVAC-Rough 8/5/2024 Approved STEPHANIE SWANSON
ELECTRICAL-Rough 8/6/2024 Corrections Issued KEVIN SARGSYAN
PLUMBING-Rough 8/8/2024 Corrections Issued KEVIN SARGSYAN
PLUMBING-Rough 8/26/2024 Approved KEVIN SARGSYAN
Drywall Nailing 9/19/2024 Partial Approval EVAN COOPER
Interior/Exterior Lathing 10/15/2024 Partial Approval KEVIN SARGSYAN
ELECTRICAL-Rough 10/25/2024 Approved ARAM AVEDISIAN
BUILDING-Rough-Frame 11/6/2024 Approved JESUS RODRIGUEZ
Green Building Rough 11/6/2024 Approved JESUS RODRIGUEZ
Verify Sprinkler Sign Off 11/6/2024 Approved JESUS RODRIGUEZ
Insulation 11/19/2024 Corrections Issued KEVIN SARGSYAN
Insulation 11/27/2024 Not Ready for Inspection KEVIN SARGSYAN
Insulation 12/4/2024 Approved KEVIN SARGSYAN
Shower Pan 12/10/2024 Approved KEVIN SARGSYAN
Drywall Nailing 12/11/2024 Approved KEVIN SARGSYAN
Interior/Exterior Lathing 2/19/2025 Approved EVAN COOPER
Interior/Exterior Lathing 3/27/2025 Approved BOBBY KEY
PLUMBING-Final 11/24/2025 Corrections Issued KEVIN SARGSYAN
HVAC-Final 12/10/2025 Approved KEVIN SARGSYAN
PLUMBING-Final 12/10/2025 Not Ready for Inspection KEVIN SARGSYAN
ELECTRICAL-Final 12/12/2025 Approved KEVIN SARGSYAN
PLUMBING-Final 12/15/2025 Approved KEVIN SARGSYAN
Final 3/3/2026 OK to Issue CofO KEVIN SARGSYAN
Green Building Final 3/3/2026 Approved KEVIN SARGSYAN
SGSOV-Seismic Gas S/O Valve 3/3/2026 SGSOV Approved KEVIN SARGSYAN
Smoke Detectors 3/3/2026 Approved KEVIN SARGSYAN