5005 S COOLIDGE AVE 90230
Certificate Information: 5005 S COOLIDGE AVE 90230
- Application / Permit
- 21010-30000-05308
- Plan Check / Job No.
- B21WL04459
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- new S.F.D. w/ 2-car garage and roof trusses
- Permit Issued
- Issued on 2/25/2022
- Issuing Office
- Current Status
- CofO Issued on 3/22/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/12/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 10/21/2021 | FELIPE HERNANDEZ |
| Corrections Issued | 10/26/2021 | FELIPE HERNANDEZ |
| Quality Review Completed | 11/3/2021 | TARIK SAOUD |
| Building Plans Picked Up | 11/5/2021 | APPLICANT |
| Plan Check Approved | 2/18/2022 | FELIPE HERNANDEZ |
| Issued | 2/25/2022 | APPLICANT |
| CofO in Progress | 3/17/2023 | JESUS RODRIGUEZ |
| Permit Finaled | 3/22/2023 | DANIEL ORRANTE |
| CofO Issued | 3/22/2023 | DANIEL ORRANTE |
| Permit Finaled | 3/22/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Low Impact Development | Cleared | 12/14/2021 | KHAING AYE |
| Eng Process Fee Ord 176,300 | Cleared | 12/20/2021 | TRACY TATE |
| Permit | Cleared | 12/20/2021 | TRACY TATE |
| Roof/Waste drainage to street | Cleared | 12/20/2021 | TRACY TATE |
| Sewer availability | Cleared | 12/20/2021 | TRACY TATE |
| Trees in Parkway | Cleared | 12/21/2021 | ADALBERTO VERA |
| Specific Plan | Cleared | 12/22/2021 | EDUARDO HERMOSO |
| Hydrant and Access approval | Cleared | 2/3/2022 | KURT CORRAL |
Contact Information
| Architect | Niemerski,, Kenneth Chester; Lic. No.: C23971 | 52 DAWNWOOD LADERA RANCH, CA 92694 |
| Contractor | T J C Home Builders Llc; Lic. No.: 1025507-B | 26940 ALISO VIEJO PKWY STE 100 ALISO VIEJO, CA 92656 |
| Engineer | Nguyen,, Huan Ngoc; Lic. No.: C64238 | 13831 TYPEE WAY IRVINE, CA 92620 |
Inspector Information
| DAKOTA LOW, (310) 914-3895 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 4/20/2022 | Conditional Approval | PATRICK QUALEY |
| Excavation/Setback/Form/Re-Bar | 5/3/2022 | Approved | PATRICK QUALEY |
| Footing/Foundation/Slab | 5/3/2022 | Approved | PATRICK QUALEY |
| Floor/Roof Diaphrgm/Shear Wall | 6/2/2022 | Partial Approval | PATRICK QUALEY |
| HVAC-Rough | 7/8/2022 | Approved | EVAN COOPER |
| PLUMBING-Rough | 7/14/2022 | Approved | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 7/20/2022 | Conditional Approval | JESUS RODRIGUEZ |
| Shower Pan | 7/20/2022 | Approved | JESUS RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 7/21/2022 | Conditional Approval | HERBERT GIRON |
| Shower Pan | 7/21/2022 | Approved | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 8/10/2022 | Approved | JESUS RODRIGUEZ |
| ELECTRICAL-Rough | 8/25/2022 | Corrections Issued | HERBERT GIRON |
| ELECTRICAL-Rough | 8/26/2022 | Approved | HERBERT GIRON |
| Interior/Exterior Lathing | 9/8/2022 | Approved | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 9/23/2022 | Approved | JESUS RODRIGUEZ |
| Green Building Rough | 9/23/2022 | Approved | JESUS RODRIGUEZ |
| MERV13>=Rough | 9/23/2022 | Approved | JESUS RODRIGUEZ |
| Verify Sprinkler Sign Off | 9/23/2022 | Approved | JESUS RODRIGUEZ |
| Insulation | 10/5/2022 | Approved | JESUS RODRIGUEZ |
| Drywall Nailing | 10/26/2022 | Approved | HERBERT GIRON |
| Interior/Exterior Lathing | 10/26/2022 | Approved | HERBERT GIRON |
| ELECTRICAL-Final | 1/5/2023 | Conditional Approval | JESUS RODRIGUEZ |
| PLUMBING-Final | 1/5/2023 | Approved | JESUS RODRIGUEZ |
| Gas Test | 1/18/2023 | Approved | JESUS RODRIGUEZ |
| HVAC-Final | 1/18/2023 | Approved | JESUS RODRIGUEZ |
| SGSOV-Seismic Gas S/O Valve | 1/18/2023 | SGSOV Approved | JESUS RODRIGUEZ |
| Service/Power Release | 2/9/2023 | Approved | JESUS RODRIGUEZ |
| Final | 2/21/2023 | Not Ready for Inspection | HERBERT GIRON |
| Green Building Final | 2/21/2023 | Not Ready for Inspection | HERBERT GIRON |
| MERV13>=Final | 2/21/2023 | Not Ready for Inspection | HERBERT GIRON |
| Smoke Detectors | 2/21/2023 | Not Ready for Inspection | HERBERT GIRON |
| ELECTRICAL-Final | 3/16/2023 | Approved | JESUS RODRIGUEZ |
| Final | 3/16/2023 | OK to Issue CofO | JESUS RODRIGUEZ |
| Green Building Final | 3/16/2023 | Approved | JESUS RODRIGUEZ |
| MERV13>=Final | 3/16/2023 | Approved | JESUS RODRIGUEZ |
| Smoke Detectors | 3/16/2023 | Approved | JESUS RODRIGUEZ |