712 S MORENO AVE 90049

Certificate Information: 712 S MORENO AVE 90049

Application / Permit
21010-30000-03833
Plan Check / Job No.
B21WL03356
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
New 2-Story Single Family Dwelling (4,130 sf) w/ att. 2-Car Garage (390 sf) and att. trellised roof patio cover (30' x 11')
Permit Issued
Issued on 12/30/2021
Issuing Office
Current Status
CofO Issued on 10/24/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/27/2021 APPLICANT
Assigned to Plan Check Engineer 8/12/2021 REZA HAGHIGHAT
Corrections Issued 8/13/2021 REZA HAGHIGHAT
Quality Review Completed 8/26/2021 TARIK SAOUD
Plan Check Approved 12/16/2021 REZA HAGHIGHAT
Building Plans Picked Up 12/22/2021 APPLICANT
Issued 12/30/2021 APPLICANT
CofO in Progress 10/4/2023 MICHAEL PELHAM
CofO in Progress 10/4/2023 MICHAEL PELHAM
Permit Finaled 10/24/2023 DANIEL ORRANTE
CofO Issued 10/24/2023 DANIEL ORRANTE
Permit Finaled 10/24/2023 DANIEL ORRANTE

Permit Application Clearance Information

Address approval Cleared 9/22/2021 DINAH GARIN
Eng Process Fee Ord 176,300 Cleared 9/22/2021 DINAH GARIN
Permit Cleared 9/22/2021 DINAH GARIN
Sewer availability Cleared 9/22/2021 DINAH GARIN
Specific Plan Cleared 10/21/2021 PEDRO AYALA
Trees in Parkway Cleared 10/28/2021 ADALBERTO VERA
Hydrant and Access approval Cleared 11/5/2021 KURT CORRAL
Low Impact Development Cleared 12/8/2021 LONDY ALVARADO
Roof/Waste drainage to street Cleared 12/8/2021 DINAH GARIN

Contact Information

Architect Niemerski,, Kenneth Chester; Lic. No.: C23971 52 DAWNWOOD      LADERA RANCH, CA 92694
Contractor T J C Home Builders Llc; Lic. No.: 1025507-B 26880 ALISO VIEJO PKWY STE 100      ALISO VIEJO, CA 92656
Engineer De, Leon, Cynthia Aguilar; Lic. No.: C31604 8061 SAN MATEO CIR      BUENA PARK, CA 90620
Engineer Nguyen,, Huan Ngoc; Lic. No.: C64238 13831 TYPEE WAY      IRVINE, CA 92620
Engineer Toedter,, Randy W; Lic. No.: S2991 7474 EISENHOWER ST      VENTURA, CA 93003

Inspector Information

ANTHONY EGSON, (310) 914-3893 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 3/7/2022 Approved OGANES TARAKHCHYAN
Deputy Reinf. Concrete 3/17/2022 Approved MICHAEL PELHAM
Excavation/Setback/Form/Re-Bar 3/18/2022 Approved OGANES TARAKHCHYAN
Deputy Wood Construction 4/27/2022 Approved MICHAEL PELHAM
Floor/Roof Diaphrgm/Shear Wall 4/28/2022 Partial Approval OGANES TARAKHCHYAN
Deputy Wood Construction 5/20/2022 Partial Approval OGANES TARAKHCHYAN
Floor/Roof Diaphrgm/Shear Wall 5/23/2022 Partial Approval KENNETH NAGLE
Deputy Drilled-In Anchors 5/25/2022 Partial Approval OGANES TARAKHCHYAN
Pre-Inspection 6/27/2022 Partial Approval OGANES TARAKHCHYAN
Sewer 7/19/2022 Approved OGANES TARAKHCHYAN
HVAC-Rough 7/20/2022 Approved JOHN KIDWELL
Underground Mechanical 7/20/2022 Conditional Approval JOHN KIDWELL
Floor/Roof Diaphrgm/Shear Wall 11/4/2022 Approved ASHLEY THOMPSON
Shower Pan 11/4/2022 Approved ASHLEY THOMPSON
PLUMBING-Rough 11/17/2022 Conditional Approval ASHLEY THOMPSON
ELECTRICAL-Rough 12/6/2022 Approved ASHLEY THOMPSON
PLUMBING-Rough 12/6/2022 Approved ASHLEY THOMPSON
BUILDING-Rough-Frame 12/9/2022 Approved ASHLEY THOMPSON
Green Building Rough 12/9/2022 Approved ASHLEY THOMPSON
Verify Sprinkler Sign Off 12/9/2022 Approved ASHLEY THOMPSON
Wood Frame 12/9/2022 Approved ASHLEY THOMPSON
Interior/Exterior Lathing 12/14/2022 Partial Approval ASHLEY THOMPSON
Insulation 12/28/2022 Approved ASHLEY THOMPSON
Drywall Nailing 1/13/2023 Approved ASHLEY THOMPSON
Interior/Exterior Lathing 1/13/2023 Approved ASHLEY THOMPSON
PLUMBING-Final 7/27/2023 Not Ready for Inspection CARLOS MATAMOROS
Gas Test 7/31/2023 Approved MICHAEL PELHAM
PLUMBING-Final 7/31/2023 Approved MICHAEL PELHAM
SGSOV-Seismic Gas S/O Valve 7/31/2023 SGSOV Approved MICHAEL PELHAM
ELECTRICAL-Final 8/3/2023 Not Ready for Inspection MEL KHACHATOURIAN
Verify Rec and Parks Fee Memo 8/3/2023 Partial Inspection MEL KHACHATOURIAN
ELECTRICAL-Final 8/22/2023 Not Ready for Inspection CARLOS MATAMOROS
HVAC-Final 8/22/2023 Corrections Issued CARLOS MATAMOROS
Smoke Detectors 8/22/2023 Corrections Issued CARLOS MATAMOROS
Smoke Detectors 9/5/2023 Approved JESUS PINEDA
ELECTRICAL-Final 9/12/2023 Corrections Issued BEN MOLSTAD
HVAC-Final 9/12/2023 Corrections Issued BEN MOLSTAD
ELECTRICAL-Final 9/19/2023 Not Ready for Inspection BEN MOLSTAD
Final 9/19/2023 Not Ready for Inspection BEN MOLSTAD
Footing/Foundation/Slab 9/19/2023 Not Ready for Inspection BEN MOLSTAD
Green Building Final 9/19/2023 Not Ready for Inspection BEN MOLSTAD
HVAC-Final 9/19/2023 Corrections Issued BEN MOLSTAD
Service/Power Release 9/19/2023 No Access for Inspection BEN MOLSTAD
ELECTRICAL-Final 9/22/2023 Corrections Issued HERBERT GIRON
Final 9/22/2023 Corrections Issued HERBERT GIRON
Footing/Foundation/Slab 9/22/2023 Approved HERBERT GIRON
HVAC-Final 9/22/2023 Approved HERBERT GIRON
Service/Power Release 9/22/2023 Not Ready for Inspection HERBERT GIRON
Final 9/27/2023 Not Ready for Inspection CARLOS MATAMOROS
Footing/Foundation/Slab 9/27/2023 Approved CARLOS MATAMOROS
Green Building Final 9/27/2023 Approved CARLOS MATAMOROS
Service/Power Release 9/27/2023 Not Ready for Inspection CARLOS MATAMOROS
Service/Power Release 10/2/2023 Corrections Issued KENNETH NAGLE
ELECTRICAL-Final 10/3/2023 Approved MICHAEL PELHAM
Final 10/3/2023 OK to Issue CofO MICHAEL PELHAM
Service/Power Release 10/3/2023 Approved MICHAEL PELHAM