1017 N KAGAWA ST 90272
Certificate Information: 1017 N KAGAWA ST 90272
- Application / Permit
- 21010-30000-01536
- Plan Check / Job No.
- B21WL01364
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- (N) 2-STORY SFD (3,808 SF) (5-BEDROOM ; 5-FULL-BATHROOM ; ONE 1/2-BATH) W. ATT. 2-CAR GARAGE (380 SF) & ATT. COVERED PORCH AT FRONT AND REAR (103 SF)
- Permit Issued
- Issued on 6/16/2022
- Issuing Office
- Current Status
- CofO Issued on 9/6/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/1/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 4/8/2021 | REZA HAGHIGHAT |
| Corrections Issued | 4/12/2021 | REZA HAGHIGHAT |
| Quality Review Completed | 4/23/2021 | KAMRAN GHOTBI RAVANDI |
| Applicant returned to address corrections | 5/11/2021 | REZA HAGHIGHAT |
| Applicant returned to address corrections | 10/7/2021 | REZA HAGHIGHAT |
| Applicant returned to address corrections | 11/3/2021 | REZA HAGHIGHAT |
| Applicant returned to address corrections | 3/15/2022 | REZA HAGHIGHAT |
| Applicant returned to address corrections | 3/21/2022 | REZA HAGHIGHAT |
| Plan Check Approved | 6/16/2022 | REZA HAGHIGHAT |
| Issued | 6/16/2022 | APPLICANT |
| Building Plans Picked Up | 7/26/2022 | APPLICANT |
| CofO in Progress | 8/28/2023 | ARAM AVEDISIAN |
| Permit Finaled | 9/6/2023 | DANIEL ORRANTE |
| Permit Finaled | 9/6/2023 | DANIEL ORRANTE |
| CofO Issued | 9/6/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 6/3/2021 | NIKTA MOUSAVI |
| Sewer availability | Cleared | 6/7/2021 | NIKTA MOUSAVI |
| Hydrant and Access approval | Cleared | 8/19/2021 | ROBERT DUFF |
| Low Impact Development | Cleared | 8/25/2021 | SUNG JOON WON |
| Roof/Waste drainage to street | Cleared | 8/26/2021 | NIKTA MOUSAVI |
| Permit | Cleared | 11/17/2021 | NIKTA MOUSAVI |
| Trees in Parkway | Cleared | 2/23/2022 | ADALBERTO VERA |
| GPI Written Notices | Cleared | 3/21/2022 | REZA HAGHIGHAT |
| Grading Pre-Inspection | Cleared | 3/21/2022 | REZA HAGHIGHAT |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Helou,, Dawn Renee; Lic. No.: C52361 | 22701 ERWIN ST WOODLAND HILLS, CA 91367 |
Inspector Information
| TEMISTOCLES CAAL, (213) 653-1908 | Office Hours: 7:00-8:00 AM MON-FRI |
| JESUS PINEDA, (213) 653-1908 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 8/15/2022 | Partial Approval | KEVIN SARGSYAN |
| Footing/Foundation/Slab | 8/17/2022 | Corrections Issued | KEVIN SARGSYAN |
| Sewer | 8/17/2022 | Approved | KEVIN SARGSYAN |
| Excavation/Setback/Form/Re-Bar | 8/18/2022 | Partial Approval | KEVIN SARGSYAN |
| Footing/Foundation/Slab | 8/18/2022 | Partial Approval | KEVIN SARGSYAN |
| Footing/Foundation/Slab | 8/22/2022 | Approved | KEVIN SARGSYAN |
| BUILDING-Rough-Frame | 8/29/2022 | Corrections Issued | KEVIN SARGSYAN |
| Deputy Wood Construction | 8/29/2022 | Approved | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 8/29/2022 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 8/31/2022 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 9/7/2022 | Partial Approval | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 9/12/2022 | Approved | KEVIN SARGSYAN |
| PLUMBING-Rough | 10/3/2022 | Corrections Issued | KEVIN SARGSYAN |
| PLUMBING-Rough | 10/7/2022 | Approved | CLAYTON GRAHAM |
| HVAC-Rough | 10/20/2022 | Approved | KEVIN SARGSYAN |
| Shower Pan | 10/20/2022 | Approved | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 10/21/2022 | Corrections Issued | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 10/28/2022 | Partial Approval | KEVIN SARGSYAN |
| Green Building Rough | 11/3/2022 | Approved | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 11/3/2022 | Partial Approval | KEVIN SARGSYAN |
| BUILDING-Rough-Frame | 11/8/2022 | Approved | KEVIN SARGSYAN |
| Verify Sprinkler Sign Off | 11/8/2022 | Approved | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 11/9/2022 | Approved | KEVIN SARGSYAN |
| Insulation | 1/23/2023 | Approved | BRENDAN LOONEY |
| Drywall Nailing | 2/3/2023 | Partial Approval | OGANES TARAKHCHYAN |
| HVAC-Final | 4/28/2023 | Corrections Issued | OGANES TARAKHCHYAN |
| HVAC-Final | 5/5/2023 | Approved | OGANES TARAKHCHYAN |
| ELECTRICAL-Final | 6/5/2023 | Approved | OGANES TARAKHCHYAN |
| PLUMBING-Final | 6/5/2023 | Approved | OGANES TARAKHCHYAN |
| Verify Rec and Parks Fee Memo | 6/7/2023 | Approved | OGANES TARAKHCHYAN |
| Gas Test | 6/8/2023 | Approved | OGANES TARAKHCHYAN |
| Drywall Nailing | 8/28/2023 | Approved | ARAM AVEDISIAN |
| Final | 8/28/2023 | OK to Issue CofO | ARAM AVEDISIAN |
| Green Building Final | 8/28/2023 | Approved | ARAM AVEDISIAN |
| SGSOV-Seismic Gas S/O Valve | 8/28/2023 | SGSOV Approved | ARAM AVEDISIAN |
| Service/Power Release | 8/28/2023 | Approved | ARAM AVEDISIAN |
| Smoke Detectors | 8/28/2023 | Approved | ARAM AVEDISIAN |