8114 N MAYNARD AVE 91304

Certificate Information: 8114 N MAYNARD AVE 91304

Application / Permit
21010-20000-06096
Plan Check / Job No.
B21VN16175
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 30'-5" X 36' ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c)-(d). ALL WORK PER WFPP
Permit Issued
Issued on 9/28/2022
Issuing Office
Valley
Current Status
CofO Issued on 11/6/2025
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 11/30/2021 APPLICANT
Assigned to Plan Check Engineer 12/3/2021 SERGIO MUNIZ
Corrections Issued 12/4/2021 SERGIO MUNIZ
Building Plans Picked Up 12/8/2021 APPLICANT
Plan Check Approved 9/28/2022 SERGIO MUNIZ
Issued 9/28/2022 APPLICANT
CofO in Progress 11/4/2025 HENRY KIM
Permit Finaled 11/6/2025 MICHAEL PELHAM
CofO Issued 11/6/2025 MICHAEL PELHAM
Permit Finaled 11/6/2025 MICHAEL PELHAM

Permit Application Clearance Information

Address approval Cleared 12/10/2021 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 12/10/2021 CARLOS AGUILERA
Sewer availability Cleared 12/10/2021 CARLOS AGUILERA
Hydrant and Access approval Cleared 2/17/2022 JOHN CONNEALLY
Low Impact Development Cleared 8/9/2022 MARTIN FRAGOSO
Roof/Waste drainage to street Cleared 8/15/2022 COLIN LOREDO
Construction near power lines Cleared 9/9/2022 WALTER RAMIREZ

Contact Information

Contractor Owner-Builder       ,

Inspector Information

JEFFREY HARTLINE, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI
CHRIS CHRISTENSEN, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 10/24/2022 Approved JEFFREY PARD
Sewer 10/24/2022 Approved JEFFREY PARD
Footing/Foundation/Slab 11/2/2022 Approved CHRIS CHRISTENSEN
Reinforced Concrete Frame 11/2/2022 Approved CHRIS CHRISTENSEN
BUILDING-Rough-Frame 12/8/2022 Not Ready for Inspection CHRIS CHRISTENSEN
Green Building Rough 12/8/2022 Not Ready for Inspection CHRIS CHRISTENSEN
Verify Sprinkler Sign Off 12/8/2022 Not Ready for Inspection CHRIS CHRISTENSEN
Wood Frame 12/8/2022 Not Ready for Inspection CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 12/13/2022 Partial Approval CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 12/16/2022 Partial Approval CHRIS CHRISTENSEN
PLUMBING-Rough 12/16/2022 Approved CHRIS CHRISTENSEN
ELECTRICAL-Rough 12/29/2022 Approved CHRIS CHRISTENSEN
Interior/Exterior Lathing 12/29/2022 Partial Approval CHRIS CHRISTENSEN
Rough-Elec/Plmb/HVAC 12/29/2022 Corrections Issued CHRIS CHRISTENSEN
BUILDING-Rough-Frame 1/13/2023 Approved CHRIS CHRISTENSEN
Green Building Rough 1/13/2023 Approved CHRIS CHRISTENSEN
Rough-Elec/Plmb/HVAC 1/13/2023 Approved CHRIS CHRISTENSEN
Underground Mechanical 1/13/2023 Partial Approval CHRIS CHRISTENSEN
Verify Sprinkler Sign Off 1/13/2023 Approved CHRIS CHRISTENSEN
Rough-Elec/Plmb/HVAC 1/19/2023 Partial Approval CHRIS CHRISTENSEN
Shower Pan 1/19/2023 Approved CHRIS CHRISTENSEN
Insulation 1/24/2023 Approved CHRIS CHRISTENSEN
Drywall Nailing 1/27/2023 Approved CHRIS CHRISTENSEN
Interior/Exterior Lathing 1/31/2023 Partial Approval CHRIS CHRISTENSEN
Final 3/23/2023 Corrections Issued CHRIS CHRISTENSEN
Green Building Final 3/23/2023 Corrections Issued CHRIS CHRISTENSEN
SGSOV-Seismic Gas S/O Valve 3/23/2023 SGSOV Approved CHRIS CHRISTENSEN
Service/Power Release 3/23/2023 Not Ready for Inspection CHRIS CHRISTENSEN
Smoke Detectors 3/23/2023 Approved CHRIS CHRISTENSEN
ELECTRICAL-Final 4/12/2023 Approved HORACE FULTZ
Final 4/12/2023 Conditional Approval HORACE FULTZ
Green Building Final 4/12/2023 Approved HORACE FULTZ
HVAC-Final 4/12/2023 Approved HORACE FULTZ
PLUMBING-Final 4/12/2023 Approved HORACE FULTZ
Pre-Inspection 4/12/2023 Partial Inspection JUSTIN HAWLEY
Service/Power Release 4/12/2023 Approved HORACE FULTZ
Final 11/4/2025 OK to Issue CofO HENRY KIM