11029 N LURLINE AVE 91311
Certificate Information: 11029 N LURLINE AVE 91311
- Application / Permit
- 21010-20000-05742
- Plan Check / Job No.
- B21VN15091
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW TWO STORY SINGLE FAMILY DWELLING W/ ATTACHED 3 CAR GARAGE W/NFPA 13D SPRINKLERS THROUGHOUT PER AA-20020-1499-PMEX PLAN 11A
- Permit Issued
- Issued on 5/12/2022
- Issuing Office
- Current Status
- CofO Issued on 4/18/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/2/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 12/2/2021 | PETER MOSESIAN |
| Corrections Issued | 12/5/2021 | PETER MOSESIAN |
| Quality Review Completed | 12/21/2021 | OMID HEDAYAT |
| Building Plans Picked Up | 1/3/2022 | APPLICANT |
| Plan Check Approved | 5/10/2022 | PETER MOSESIAN |
| Issued | 5/12/2022 | APPLICANT |
| CofO in Progress | 3/24/2023 | JEFFREY PARD |
| CofO Issued | 4/18/2023 | MICHAEL SMITH |
| Permit Finaled | 4/18/2023 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 1/19/2022 | LEE GUILBEAUX |
| Eng Process Fee Ord 176,300 | Cleared | 1/19/2022 | LEE GUILBEAUX |
| Miscellaneous | Cleared | 1/19/2022 | LEE GUILBEAUX |
| Permit | Cleared | 1/19/2022 | LEE GUILBEAUX |
| Roof/Waste drainage to street | Cleared | 1/19/2022 | LEE GUILBEAUX |
| Sewer availability | Cleared | 1/19/2022 | LEE GUILBEAUX |
| Public Works-Highway Ded. | Cleared | 1/19/2022 | LEE GUILBEAUX |
| "T" removal | Cleared | 1/20/2022 | LAUREN PADICK |
| ZA Case | Cleared | 1/20/2022 | LAUREN PADICK |
| ZA Case | Cleared | 1/20/2022 | LAUREN PADICK |
| ZA Case | Cleared | 1/20/2022 | LAUREN PADICK |
| Low Impact Development | Cleared | 4/6/2022 | AMMAR ELTAWIL |
| Hydrant and Access approval | Cleared | 4/26/2022 | KURT CORRAL |
| Grading Pre-Inspection | Cleared | 5/10/2022 | PETER MOSESIAN |
Contact Information
| Contractor | Shapell Homes Inc; Lic. No.: 1001034-B | 1140 VIRGINIA DR ATTN: TOLL BROTHERS - TAGGERT/LEGAL FORT WASHINGTON, PA 19034 |
| Engineer | Braatz,, Tara Elizabeth; Lic. No.: C79028 | 24855 CALLE CARMEL LAGUNA HILLS, CA 92653 |
| Engineer | Van, Gaale, Mark Allan; Lic. No.: C58680 | 185 W ORANGEWOOD AVE STE 200 ORANGE, CA 92868 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Final | 7/5/2022 | Corrections Issued | HENRY KIM |
| PLUMBING-Rough | 7/5/2022 | Partial Approval | HENRY KIM |
| Sewer | 7/5/2022 | Approved | HENRY KIM |
| Deputy Pre-Stress Concrete | 8/16/2022 | Approved | JEFFREY PARD |
| Footing/Foundation/Slab | 8/16/2022 | Approved | JEFFREY PARD |
| Underground Mechanical | 9/12/2022 | Approved | HENRY KIM |
| Floor/Roof Diaphrgm/Shear Wall | 9/15/2022 | Partial Approval | JEFFREY PARD |
| Floor/Roof Diaphrgm/Shear Wall | 9/28/2022 | Partial Approval | JEFFREY PARD |
| PLUMBING-Rough | 10/13/2022 | Approved | JEFFREY PARD |
| Deputy Wood Construction | 10/17/2022 | Approved | JEFFREY PARD |
| ELECTRICAL-Rough | 10/18/2022 | Not Ready for Inspection | JEFFREY PARD |
| HVAC-Rough | 10/18/2022 | Approved | JEFFREY PARD |
| Shower Pan | 10/21/2022 | Approved | JEFFREY PARD |
| Floor/Roof Diaphrgm/Shear Wall | 11/1/2022 | Approved | JEFFREY PARD |
| BUILDING-Rough-Frame | 11/3/2022 | Partial Approval | JEFFREY PARD |
| ELECTRICAL-Rough | 11/3/2022 | Approved | JEFFREY PARD |
| Green Building Rough | 11/3/2022 | Not Ready for Inspection | JEFFREY PARD |
| Interior/Exterior Lathing | 11/3/2022 | Approved | JEFFREY PARD |
| MERV13>=Rough | 11/3/2022 | Not Ready for Inspection | JEFFREY PARD |
| Verify Sprinkler Sign Off | 11/3/2022 | Approved | JEFFREY PARD |
| Insulation | 11/8/2022 | Approved | JEFFREY PARD |
| Drywall Nailing | 11/16/2022 | Approved | JEFFREY PARD |
| Green Building Rough | 11/16/2022 | Approved | JEFFREY PARD |
| Interior/Exterior Lathing | 12/13/2022 | Approved | HENRY KIM |
| Gas Test | 1/9/2023 | Corrections Issued | HENRY KIM |
| SGSOV-Seismic Gas S/O Valve | 1/12/2023 | SGSOV Approved | JEFFREY PARD |
| Gas Test | 1/18/2023 | Approved | JEFFREY PARD |
| SGSOV-Seismic Gas S/O Valve | 1/19/2023 | SGSOV Approved | HENRY KIM |
| Service/Power Release | 2/9/2023 | Approved | HENRY KIM |
| ELECTRICAL-Final | 3/2/2023 | Corrections Issued | HENRY KIM |
| HVAC-Final | 3/2/2023 | Approved | HENRY KIM |
| PLUMBING-Final | 3/2/2023 | Not Ready for Inspection | HENRY KIM |
| Special/Order Compliance | 3/2/2023 | Partial Inspection | JUSTIN HAWLEY |
| BUILDING-Rough-Frame | 3/23/2023 | Approved | JEFFREY PARD |
| ELECTRICAL-Final | 3/23/2023 | Approved | JEFFREY PARD |
| Final | 3/23/2023 | OK to Issue CofO | JEFFREY PARD |
| Green Building Final | 3/23/2023 | Approved | JEFFREY PARD |
| MERV13>=Final | 3/23/2023 | Approved | JEFFREY PARD |
| MERV13>=Rough | 3/23/2023 | Approved | JEFFREY PARD |
| PLUMBING-Final | 3/23/2023 | Approved | JEFFREY PARD |
| Smoke Detectors | 3/23/2023 | Approved | JEFFREY PARD |