16661 W ADLON ROAD 91436

Certificate Information: 16661 W ADLON ROAD 91436

Application / Permit
21010-20000-05697
Plan Check / Job No.
B21VN14992
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 60'8" X 73' 2-STORY SFD WITH HABITABLE BASEMENT AND WITH ATTACHED TWO CAR GARAGE , NFPA-13D FIRE SPRINLERS THROUGHOUT, ALL WORK PER ENGINEERING
Permit Issued
Issued on 11/1/2024
Issuing Office
Valley
Current Status
Issued on 11/1/2024
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 11/1/2021 APPLICANT
Assigned to Plan Check Engineer 11/18/2021 RARES BODEA
Corrections Issued 11/24/2021 RARES BODEA
Quality Review Completed 12/2/2021 STEVEN KIM
Building Plans Picked Up 12/6/2021 APPLICANT
Applicant returned to address corrections 6/8/2022 RARES BODEA
Applicant returned to address corrections 9/21/2022 RARES BODEA
Plan Check Approved 12/15/2022 RARES BODEA
Issued 11/1/2024 APPLICANT

Permit Application Clearance Information

Address approval Cleared 12/8/2021 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 12/8/2021 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 12/8/2021 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 12/8/2021 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 12/8/2021 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 12/9/2021 CARLOS AGUILERA
Sewer availability Cleared 12/9/2021 CARLOS AGUILERA
Distance to fire station Cleared 2/23/2022 JOHN CONNEALLY
Hydrant and Access approval Cleared 2/23/2022 JOHN CONNEALLY
BHO/Hillside ordinance Cleared 4/1/2022 CARLOS AGUILERA
Low Impact Development Cleared 6/3/2022 JULIAN SUNG
Roof/Waste drainage to street Cleared 6/14/2022 CARLOS AGUILERA
GPI Written Notices Cleared 9/21/2022 RARES BODEA
Grading Pre-Inspection Cleared 9/21/2022 RARES BODEA

Contact Information

Contractor Owner-Builder       ,
Engineer Roberts,, Jeffrey Allan; Lic. No.: C56881 8325 FOOTHILL BLVD. STE A      SUNLAND, CA 91040

Inspector Information

THOMAS FINNILA, (818) 774-4324 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 12/2/2024 Not Ready for Inspection THOMAS FINNILA
Sewer 12/4/2024 Not Ready for Inspection THOMAS FINNILA
Excavation/Setback/Form/Re-Bar 12/19/2024 Partial Inspection THOMAS FINNILA
Deputy Reinf. Concrete 12/20/2024 Corrections Issued THOMAS FINNILA
Deputy Reinf. Concrete 12/30/2024 Partial Approval SEAN WIRCH
Footing/Foundation/Slab 12/30/2024 Not Ready for Inspection THOMAS FINNILA
Footing/Foundation/Slab 1/7/2025 Corrections Issued THOMAS FINNILA
Deputy Reinf. Concrete 3/3/2025 Partial Approval SEAN WIRCH
Footing/Foundation/Slab 3/3/2025 Conditional Approval THOMAS FINNILA
Footing/Foundation/Slab 3/13/2025 Partial Approval THOMAS FINNILA
Deputy Reinf. Concrete 3/17/2025 Conditional Approval THOMAS FINNILA
Underground Mechanical 4/4/2025 Corrections Issued THOMAS FINNILA
Underground Mechanical 4/9/2025 Not Ready for Inspection THOMAS FINNILA
Underground Mechanical 4/16/2025 Partial Approval SEAN WIRCH
Deputy Reinf. Concrete 5/7/2025 Partial Approval JOHN KIDWELL
Excavation/Setback/Form/Re-Bar 5/7/2025 Partial Approval JOHN KIDWELL
Service/Power Release 5/22/2025 Not Ready for Inspection JOHN COLEMAN
Underground Mechanical 8/4/2025 Corrections Issued JOHN KIDWELL
Service/Power Release 8/6/2025 Not Ready for Inspection THOMAS FINNILA
Underground Mechanical 8/7/2025 Conditional Approval THOMAS FINNILA
Deputy Reinf. Concrete 8/12/2025 Conditional Approval THOMAS FINNILA
Excavation/Setback/Form/Re-Bar 8/12/2025 Corrections Issued THOMAS FINNILA
Excavation/Setback/Form/Re-Bar 8/15/2025 Corrections Issued THOMAS FINNILA
Deputy Reinf. Concrete 8/18/2025 Conditional Approval THOMAS FINNILA
Excavation/Setback/Form/Re-Bar 9/26/2025 Partial Approval SEAN WIRCH
Deputy Reinf. Concrete 9/29/2025 Conditional Approval THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 10/29/2025 Corrections Issued THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 12/15/2025 Corrections Issued THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 12/19/2025 Partial Approval THOMAS FINNILA
ELECTRICAL-Rough 3/9/2026 Approved SEAN WIRCH
Floor/Roof Diaphrgm/Shear Wall 3/9/2026 Partial Approval SEAN WIRCH
HVAC-Rough 3/9/2026 Approved SEAN WIRCH
PLUMBING-Rough 3/9/2026 Approved SEAN WIRCH
BUILDING-Rough-Frame 3/25/2026 Corrections Issued THOMAS FINNILA
Green Building Rough 3/25/2026 Corrections Issued THOMAS FINNILA
Verify Sprinkler Sign Off 3/25/2026 Not Ready for Inspection THOMAS FINNILA
BUILDING-Rough-Frame 4/6/2026 Approved THOMAS FINNILA
Green Building Rough 4/6/2026 Approved THOMAS FINNILA
Interior/Exterior Lathing 4/6/2026 Not Ready for Inspection THOMAS FINNILA
Verify Sprinkler Sign Off 4/6/2026 Approved THOMAS FINNILA
Insulation 4/20/2026 Approved JOHN KIDWELL
Interior/Exterior Lathing 4/20/2026 Partial Approval JOHN KIDWELL
Shower Pan 4/20/2026 Approved JOHN KIDWELL
Drywall Nailing 5/4/2026 Approved JOHN KIDWELL
Interior/Exterior Lathing 5/4/2026 Partial Approval JOHN KIDWELL