4225 N TOLUCA ROAD 91602
Certificate Information: 4225 N TOLUCA ROAD 91602
- Application / Permit
- 21010-20000-05329
- Plan Check / Job No.
- B21VN13859
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- (N) 2-STORY SFD W/ ATTACHED 4-CAR GARAGE (NFPA-13D FIRE SPRINKLERS THROUGHOUT)
- Permit Issued
- Issued on 8/10/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 2/6/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/8/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 11/4/2021 | NILOOFAR MEHRAIN |
| Corrections Issued | 11/9/2021 | NILOOFAR MEHRAIN |
| Quality Review Completed | 11/10/2021 | STEVEN KIM |
| Building Plans Picked Up | 12/15/2021 | APPLICANT |
| Applicant returned to address corrections | 3/24/2022 | NILOOFAR MEHRAIN |
| Applicant returned to address corrections | 7/19/2022 | NILOOFAR MEHRAIN |
| Plan Check Approved | 8/2/2022 | NILOOFAR MEHRAIN |
| Issued | 8/10/2022 | APPLICANT |
| CofO in Progress | 1/24/2025 | CHRISTOPHER ROJAS |
| Permit Finaled | 2/6/2025 | RUBEN SALAS |
| CofO Issued | 2/6/2025 | RUBEN SALAS |
| Permit Finaled | 2/6/2025 | RUBEN SALAS |
Permit Application Clearance Information
| ZA Case | Cleared | 3/16/2022 | MIGUEL GAMBOA |
| Hydrant and Access approval | Cleared | 4/22/2022 | DWAYNE LAURENT |
| Address approval | Cleared | 5/13/2022 | CARLOS AGUILERA |
| Permit | Cleared | 5/13/2022 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 5/16/2022 | CARLOS AGUILERA |
| Sewer availability | Cleared | 5/16/2022 | CARLOS AGUILERA |
| Trees in Parkway | Cleared | 5/24/2022 | ADALBERTO VERA |
| Low Impact Development | Cleared | 7/6/2022 | LONDY ALVARADO |
| Roof/Waste drainage to street | Cleared | 7/6/2022 | CARLOS AGUILERA |
Contact Information
| Contractor | Property Services And Development Inc; Lic. No.: 833190-B | 6711 FOREST LAWN DRIVE #105 LOS ANGELES, CA 90068 |
| Engineer | Kaddorah,, Salim Izzat; Lic. No.: C43757 | PO BOX 546 HERMOSA BEACH, CA 90254 |
Inspector Information
| JAVIER RAMOS JR, (818) 374-1163 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 8/31/2022 | Corrections Issued | THOMAS FINNILA |
| PLUMBING-Rough | 9/15/2022 | Partial Approval | THOMAS FINNILA |
| ELECTRICAL-Rough | 9/28/2022 | Partial Approval | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 9/28/2022 | Not Ready for Inspection | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 10/5/2022 | Partial Approval | THOMAS FINNILA |
| Excavation/Setback/Form/Re-Bar | 10/14/2022 | Approved | JACK KARGODORIAN |
| Deputy Reinf. Concrete | 10/18/2022 | Partial Approval | JACK KARGODORIAN |
| Deputy Steel/Welding | 11/17/2022 | Conditional Approval | MICHAEL SMITH |
| Floor/Roof Diaphrgm/Shear Wall | 12/1/2022 | Partial Approval | JOHN COLEMAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/5/2023 | Corrections Issued | JACK KARGODORIAN |
| Deputy Wood Construction | 4/6/2023 | Partial Approval | JACK KARGODORIAN |
| ELECTRICAL-Rough | 6/15/2023 | Approved | JACK KARGODORIAN |
| HVAC-Rough | 6/15/2023 | Approved | JACK KARGODORIAN |
| PLUMBING-Rough | 6/15/2023 | Approved | JACK KARGODORIAN |
| BUILDING-Rough-Frame | 6/27/2023 | Approved | JUAN VALENZUELA |
| ELECTRICAL-Rough | 6/27/2023 | Corrections Issued | JUAN VALENZUELA |
| Green Building Rough | 6/27/2023 | Approved | JUAN VALENZUELA |
| Verify Sprinkler Sign Off | 6/27/2023 | Approved | JUAN VALENZUELA |
| Deputy Wood Construction | 6/28/2023 | Conditional Approval | DAVID MATSON |
| Drywall Nailing | 9/22/2023 | Approved | JACK KARGODORIAN |
| Shower Pan | 9/26/2023 | Approved | THOMAS FINNILA |
| Footing/Foundation/Slab | 10/11/2023 | Not Ready for Inspection | JOHN COLEMAN |
| Interior/Exterior Lathing | 10/17/2023 | Approved | RYAN SALAZAR |
| Shower Pan | 10/17/2023 | Approved | RYAN SALAZAR |
| ELECTRICAL-Final | 5/17/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| ELECTRICAL-Rough | 5/17/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Rough-Elec/Plmb/HVAC | 5/17/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Final | 5/29/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Footing/Foundation/Slab | 5/29/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Green Building Final | 5/29/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Pre-Inspection | 5/29/2024 | Partial Approval | CHRISTOPHER ROJAS |
| SGSOV-Seismic Gas S/O Valve | 5/29/2024 | SGSOV Not Ready | CHRISTOPHER ROJAS |
| Service/Power Release | 5/29/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Smoke Detectors | 5/29/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| Service/Power Release | 6/6/2024 | Approved | CHRISTOPHER ROJAS |
| Final | 7/24/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Footing/Foundation/Slab | 7/24/2024 | Approved | CHRISTOPHER ROJAS |
| Green Building Final | 7/24/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| SGSOV-Seismic Gas S/O Valve | 7/24/2024 | SGSOV Approved | CHRISTOPHER ROJAS |
| Smoke Detectors | 7/24/2024 | Approved | CHRISTOPHER ROJAS |
| Final | 11/14/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Green Building Final | 11/14/2024 | Approved | CHRISTOPHER ROJAS |
| Final | 1/24/2025 | OK to Issue CofO | CHRISTOPHER ROJAS |