8681 N HADDON AVE 91352

Certificate Information: 8681 N HADDON AVE 91352

Application / Permit
21010-20000-05218
Plan Check / Job No.
B21VN13636
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW DETACHED 2-STORY ADU.
Permit Issued
Issued on 3/2/2022
Issuing Office
Current Status
CofO Issued on 10/22/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 10/6/2021 APPLICANT
Assigned to Plan Check Engineer 10/8/2021 JOE VO
Corrections Issued 10/11/2021 JOE VO
Applicant returned to address corrections 2/28/2022 JOE VO
Plan Check Approved 3/2/2022 JOE VO
Issued 3/2/2022 APPLICANT
CofO in Progress 10/17/2022 CHRISTOPHER DELLEFIELD
Permit Finaled 10/22/2022 MICHAEL SMITH
CofO Issued 10/22/2022 MICHAEL SMITH
Permit Finaled 10/22/2022 MICHAEL SMITH

Permit Application Clearance Information

Address approval Cleared 10/25/2021 JOSE DUARTE-DIAZ
Eng Process Fee Ord 176,300 Cleared 10/25/2021 JOSE DUARTE-DIAZ
Sewer availability Cleared 10/25/2021 JOSE DUARTE-DIAZ
Hydrant and Access approval Cleared 2/4/2022 MATTHEW CRAIG
Construction near power lines Cleared 2/18/2022 RIDWAN HARDY
Roof/Waste drainage to street Cleared 3/1/2022 JOSE DUARTE-DIAZ

Contact Information

Contractor Owner-Builder       ,

Inspector Information

MATTHEW NELSON, (818) 374-1170 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 3/29/2022 Partial Approval CHRISTOPHER DELLEFIELD
Deputy Drilled-In Anchors 3/30/2022 No Result Entered ADRIAN GAUTHIER
Footing/Foundation/Slab 4/1/2022 Approved JENNIFER RABUCHIN
Floor/Roof Diaphrgm/Shear Wall 4/12/2022 Corrections Issued CHRISTOPHER DELLEFIELD
Deputy Wood Construction 4/13/2022 Conditional Approval CHRISTOPHER DELLEFIELD
Floor/Roof Diaphrgm/Shear Wall 4/14/2022 Partial Approval CHRISTOPHER DELLEFIELD
Wood Frame 4/14/2022 Not Ready for Inspection CHRISTOPHER DELLEFIELD
Floor/Roof Diaphrgm/Shear Wall 4/27/2022 Approved CHRISTOPHER DELLEFIELD
HVAC-Rough 4/27/2022 Approved CHRISTOPHER DELLEFIELD
Deputy Wood Construction 5/9/2022 Conditional Approval CHRISTOPHER DELLEFIELD
Floor/Roof Diaphrgm/Shear Wall 5/9/2022 Approved CHRISTOPHER DELLEFIELD
PLUMBING-Rough 5/9/2022 Not Ready for Inspection CHRISTOPHER DELLEFIELD
Pre-Inspection 5/9/2022 Corrections Issued CHRISTOPHER DELLEFIELD
Sewer 5/11/2022 Approved CHRISTOPHER DELLEFIELD
Underground Mechanical 5/11/2022 Approved CHRISTOPHER DELLEFIELD
BUILDING-Rough-Frame 5/13/2022 Approved CHRISTOPHER DELLEFIELD
ELECTRICAL-Rough 5/13/2022 Approved CHRISTOPHER DELLEFIELD
HVAC-Rough 5/13/2022 Approved CHRISTOPHER DELLEFIELD
MERV13>=Rough 5/13/2022 Approved CHRISTOPHER DELLEFIELD
PLUMBING-Rough 5/13/2022 Approved CHRISTOPHER DELLEFIELD
Verify Sprinkler Sign Off 5/13/2022 Approved CHRISTOPHER DELLEFIELD
Insulation 5/17/2022 Corrections Issued CHRISTOPHER DELLEFIELD
Interior/Exterior Lathing 5/17/2022 Not Ready for Inspection CHRISTOPHER DELLEFIELD
Insulation 5/19/2022 Approved CHRISTOPHER DELLEFIELD
Interior/Exterior Lathing 5/19/2022 Conditional Approval CHRISTOPHER DELLEFIELD
Drywall Nailing 5/25/2022 Approved CHRISTOPHER DELLEFIELD
Interior/Exterior Lathing 5/25/2022 Approved CHRISTOPHER DELLEFIELD
Interior/Exterior Lathing 5/31/2022 Approved CHRISTOPHER DELLEFIELD
Shower Pan 5/31/2022 Approved CHRISTOPHER DELLEFIELD
ELECTRICAL-Final 9/9/2022 Corrections Issued CHRISTOPHER DELLEFIELD
Final 9/9/2022 Corrections Issued CHRISTOPHER DELLEFIELD
HVAC-Final 9/9/2022 Corrections Issued CHRISTOPHER DELLEFIELD
MERV13>=Final 9/9/2022 Corrections Issued CHRISTOPHER DELLEFIELD
PLUMBING-Final 9/9/2022 Corrections Issued CHRISTOPHER DELLEFIELD
SGSOV-Seismic Gas S/O Valve 9/9/2022 SGSOV Not Ready CHRISTOPHER DELLEFIELD
Service/Power Release 9/9/2022 Not Ready for Inspection CHRISTOPHER DELLEFIELD
Smoke Detectors 9/9/2022 Approved CHRISTOPHER DELLEFIELD
Final 9/14/2022 Corrections Issued DAVID MATSON
MERV13>=Final 9/14/2022 Approved DAVID MATSON
SGSOV-Seismic Gas S/O Valve 9/14/2022 SGSOV Approved DAVID MATSON
Service/Power Release 9/14/2022 Not Ready for Inspection DAVID MATSON
Final 10/7/2022 Corrections Issued CHRISTOPHER DELLEFIELD
Service/Power Release 10/7/2022 Not Ready for Inspection CHRISTOPHER DELLEFIELD
ELECTRICAL-Final 10/17/2022 Approved CHRISTOPHER DELLEFIELD
Final 10/17/2022 OK to Issue CofO CHRISTOPHER DELLEFIELD
HVAC-Final 10/17/2022 Approved CHRISTOPHER DELLEFIELD
PLUMBING-Final 10/17/2022 Approved CHRISTOPHER DELLEFIELD
Service/Power Release 10/17/2022 Approved CHRISTOPHER DELLEFIELD