6130 N WILBUR AVE 91335
Certificate Information: 6130 N WILBUR AVE 91335
- Application / Permit
- 21010-20000-05135
- Plan Check / Job No.
- B21VN13454
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 54'-7" X 37'-2" (2) STORY SINGLE FAMILY DWELLING WITH ATTACHED GARAGE AND ROOF DECK; EQUIPPED WITH NFPA 13-D FIRE SPRINKLERS THROUGHOUT/ATT. 2-CAR GARAGE COMPLY WITH DEPARTMENT ORDER effective date 01/31/2022. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE
- Permit Issued
- Issued on 7/1/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 9/12/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/15/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 10/15/2021 | SELLA BENYAMIN |
| Corrections Issued | 10/19/2021 | SELLA BENYAMIN |
| Quality Review Completed | 10/21/2021 | STEVEN KIM |
| Applicant returned to address corrections | 4/26/2022 | SELLA BENYAMIN |
| Plan Check Approved | 6/24/2022 | SELLA BENYAMIN |
| Issued | 7/1/2022 | APPLICANT |
| CofO in Progress | 7/25/2025 | JON MCHUGH |
| No Progress | 8/27/2025 | SEAN WIRCH |
| CofO in Progress | 8/27/2025 | SEAN WIRCH |
| Permit Finaled | 9/12/2025 | MICHAEL PELHAM |
| CofO Issued | 9/12/2025 | MICHAEL PELHAM |
| Permit Finaled | 9/12/2025 | MICHAEL PELHAM |
Permit Application Clearance Information
| Address approval | Cleared | 10/26/2021 | CARLOS AGUILERA |
| Permit | Cleared | 10/26/2021 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 1/31/2022 | CARLOS AGUILERA |
| Sewer availability | Cleared | 1/31/2022 | CARLOS AGUILERA |
| Hydrant and Access approval | Cleared | 3/11/2022 | LARRY REDDEN |
| Trees in Parkway | Cleared | 4/8/2022 | ADALBERTO VERA |
| ZI | Cleared | 4/21/2022 | PABLO ESTRADA |
| Low Impact Development | Cleared | 5/12/2022 | MARCO SANCHEZ |
| Roof/Waste drainage to street | Cleared | 5/17/2022 | CARLOS AGUILERA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Gharai,, Armin; Lic. No.: C61464 | 6701 CORIE LN WEST HILLS, CA 91307 |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 11/10/2022 | Corrections Issued | JEFFREY PARD |
| PLUMBING-Rough | 11/16/2022 | Approved | SEAN HAUPT |
| Excavation/Setback/Form/Re-Bar | 11/23/2022 | Not Ready for Inspection | DAVID SANDOVAL |
| Footing/Foundation/Slab | 11/23/2022 | Corrections Issued | DAVID SANDOVAL |
| Excavation/Setback/Form/Re-Bar | 11/28/2022 | Approved | SEAN HAUPT |
| Footing/Foundation/Slab | 11/28/2022 | Approved | SEAN HAUPT |
| Deputy Reinf. Concrete | 11/30/2022 | Partial Approval | JON MCHUGH |
| Deputy Steel/Welding | 12/23/2022 | Conditional Approval | JON MCHUGH |
| Deputy Steel/Welding | 12/27/2022 | Conditional Approval | JON MCHUGH |
| BUILDING-Rough-Frame | 12/30/2022 | Not Ready for Inspection | JON MCHUGH |
| Green Building Rough | 12/30/2022 | Not Ready for Inspection | JON MCHUGH |
| Verify Sprinkler Sign Off | 12/30/2022 | Not Ready for Inspection | JON MCHUGH |
| Wood Frame | 12/30/2022 | Not Ready for Inspection | JON MCHUGH |
| BUILDING-Rough-Frame | 1/24/2023 | Not Ready for Inspection | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 1/24/2023 | Partial Approval | JON MCHUGH |
| Green Building Rough | 1/24/2023 | Not Ready for Inspection | JON MCHUGH |
| Verify Sprinkler Sign Off | 1/24/2023 | Not Ready for Inspection | JON MCHUGH |
| Wood Frame | 1/24/2023 | Not Ready for Inspection | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 2/2/2023 | Not Ready for Inspection | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 2/7/2023 | Partial Approval | JON MCHUGH |
| PLUMBING-Rough | 3/6/2023 | Approved | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 3/23/2023 | Approved | JON MCHUGH |
| Interior/Exterior Lathing | 4/27/2023 | Partial Approval | JON MCHUGH |
| ELECTRICAL-Rough | 5/18/2023 | Corrections Issued | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 5/18/2023 | Corrections Issued | JON MCHUGH |
| HVAC-Rough | 5/18/2023 | Not Ready for Inspection | JON MCHUGH |
| Rough-Elec/Plmb/HVAC | 5/18/2023 | Not Ready for Inspection | JON MCHUGH |
| Wood Frame | 5/18/2023 | Not Ready for Inspection | JON MCHUGH |
| ELECTRICAL-Rough | 6/12/2023 | Approved | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 6/12/2023 | Approved | JON MCHUGH |
| HVAC-Rough | 6/12/2023 | Approved | JON MCHUGH |
| Rough-Elec/Plmb/HVAC | 6/12/2023 | Approved | JON MCHUGH |
| Wood Frame | 6/12/2023 | Approved | JON MCHUGH |
| Insulation | 6/21/2023 | Corrections Issued | JON MCHUGH |
| Sewer | 6/21/2023 | Corrections Issued | JON MCHUGH |
| Drywall Nailing | 7/20/2023 | Approved | MORRIS JACKSON |
| Shower Pan | 9/7/2023 | Approved | MORRIS JACKSON |
| Interior/Exterior Lathing | 9/13/2023 | Approved | JON MCHUGH |
| Underground Mechanical | 2/26/2024 | Approved | JON MCHUGH |
| Sewer | 12/2/2024 | Approved | JON MCHUGH |
| Special/Order Compliance | 12/2/2024 | Corrections Issued | JON MCHUGH |
| BUILDING-Rough-Frame | 2/25/2025 | Approved | JON MCHUGH |
| Final | 2/25/2025 | Corrections Issued | JON MCHUGH |
| Green Building Final | 2/25/2025 | Not Ready for Inspection | JON MCHUGH |
| Green Building Rough | 2/25/2025 | Approved | JON MCHUGH |
| SGSOV-Seismic Gas S/O Valve | 2/25/2025 | SGSOV Approved | JON MCHUGH |
| Service/Power Release | 2/25/2025 | Not Ready for Inspection | JON MCHUGH |
| Smoke Detectors | 2/25/2025 | Not Ready for Inspection | JON MCHUGH |
| Verify Sprinkler Sign Off | 2/25/2025 | Approved | JON MCHUGH |
| ELECTRICAL-Final | 3/24/2025 | Not Ready for Inspection | JON MCHUGH |
| Final | 3/24/2025 | Corrections Issued | JON MCHUGH |
| Gas Test | 3/24/2025 | Approved | JON MCHUGH |
| Green Building Final | 3/24/2025 | Not Ready for Inspection | JON MCHUGH |
| PLUMBING-Final | 3/24/2025 | Not Ready for Inspection | JON MCHUGH |
| Service/Power Release | 3/24/2025 | Approved | JON MCHUGH |
| Smoke Detectors | 3/24/2025 | Not Ready for Inspection | JON MCHUGH |
| ELECTRICAL-Final | 7/25/2025 | Approved | JON MCHUGH |
| Final | 7/25/2025 | OK to Issue CofO | JON MCHUGH |
| Green Building Final | 7/25/2025 | Approved | JON MCHUGH |
| HVAC-Final | 7/25/2025 | Approved | JON MCHUGH |
| PLUMBING-Final | 7/25/2025 | Approved | JON MCHUGH |
| Smoke Detectors | 7/25/2025 | Approved | JON MCHUGH |