12525 N RIDGELINE RD 91326

Certificate Information: 12525 N RIDGELINE RD 91326

Application / Permit
21010-20000-04590
Plan Check / Job No.
B21VN11972
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PROPOSE SFD W/ ATTACHED GARAGE_STANDARD PLAN #654_PLAN 4CR_BUILDING SHALL BE FULLY SPRINKLER THROUGH OUT WITH NFPA 13D.
Permit Issued
Issued on 3/18/2022
Issuing Office
Current Status
CofO Issued on 5/10/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/3/2021 APPLICANT
Assigned to Plan Check Engineer 10/7/2021 DAWN MC NULTY
Corrections Issued 10/14/2021 DAWN MC NULTY
Quality Review Completed 10/21/2021 STEVEN KIM
Building Plans Picked Up 10/29/2021 APPLICANT
Plan Check Approved 3/14/2022 DAWN MC NULTY
Issued 3/18/2022 APPLICANT
CofO in Progress 4/4/2023 JEFFREY PARD
No Progress 4/6/2023 MICHAEL SMITH
CofO in Progress 5/10/2023 MICHAEL SMITH
CofO in Progress 5/10/2023 MICHAEL SMITH
CofO Issued 5/10/2023 MICHAEL SMITH
Permit Finaled 5/10/2023 MICHAEL SMITH

Permit Application Clearance Information

"T" removal Cleared 11/30/2021 LAUREN PADICK
CPC Cleared 11/30/2021 LAUREN PADICK
CPC Cleared 11/30/2021 LAUREN PADICK
CPC Cleared 11/30/2021 LAUREN PADICK
Specific Plan Cleared 11/30/2021 LAUREN PADICK
Tract Map conditions Cleared 11/30/2021 LAUREN PADICK
ZA Case Cleared 11/30/2021 LAUREN PADICK
ZA Case Cleared 11/30/2021 LAUREN PADICK
Low Impact Development Cleared 12/16/2021 AMMAR ELTAWIL
Address approval Cleared 1/10/2022 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 1/10/2022 LEE GUILBEAUX
Permit Cleared 1/10/2022 LEE GUILBEAUX
Public Works-Highway Ded. Cleared 1/10/2022 DAWN MC NULTY
Roof/Waste drainage to street Cleared 1/10/2022 LEE GUILBEAUX
Sewer availability Cleared 1/10/2022 LEE GUILBEAUX
Hydrant and Access approval Cleared 3/1/2022 KURT CORRAL

Contact Information

Contractor Shapell Homes Inc; Lic. No.: 1001034-B 1140 VIRGINIA DR ATTN: TOLL   BROTHERS - TAGGERT/LEGAL    FORT WASHINGTON, PA 19034
Engineer Nguyen,, Huan Ngoc; Lic. No.: C64238 13831 TYPEE WAY      IRVINE, CA 92620

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 5/31/2022 Partial Approval HENRY KIM
Footing/Foundation/Slab 6/17/2022 Approved HENRY KIM
METHANE-Barrier 6/17/2022 Approved HENRY KIM
METHANE-Subgrade 6/17/2022 Approved HENRY KIM
Deputy Reinf. Concrete 6/21/2022 Conditional Approval HENRY KIM
Floor/Roof Diaphrgm/Shear Wall 7/27/2022 Partial Approval HENRY KIM
Sewer 8/4/2022 Approved HENRY KIM
Interior/Exterior Lathing 11/2/2022 Corrections Issued JEFFREY PARD
Floor/Roof Diaphrgm/Shear Wall 11/3/2022 Approved JEFFREY PARD
BUILDING-Rough-Frame 11/8/2022 Not Ready for Inspection JEFFREY PARD
ELECTRICAL-Rough 11/8/2022 Approved JEFFREY PARD
Green Building Rough 11/8/2022 Approved JEFFREY PARD
HVAC-Rough 11/8/2022 Approved JEFFREY PARD
Interior/Exterior Lathing 11/8/2022 Not Ready for Inspection JEFFREY PARD
METHANE-Rough 11/8/2022 Approved JEFFREY PARD
PLUMBING-Rough 11/8/2022 Not Ready for Inspection JEFFREY PARD
Shower Pan 11/8/2022 Approved JEFFREY PARD
Verify Sprinkler Sign Off 11/8/2022 No Access for Inspection JEFFREY PARD
PLUMBING-Rough 11/10/2022 Approved JEFFREY PARD
BUILDING-Rough-Frame 11/15/2022 Approved JEFFREY PARD
Interior/Exterior Lathing 11/15/2022 Approved JEFFREY PARD
Shower Pan 11/15/2022 Approved JEFFREY PARD
Verify Sprinkler Sign Off 11/15/2022 Approved JEFFREY PARD
Insulation 11/18/2022 Approved JEFFREY PARD
Drywall Nailing 11/23/2022 Approved JEFFREY PARD
Interior/Exterior Lathing 12/19/2022 Approved HENRY KIM
PLUMBING-Rough 12/29/2022 Approved JEFFREY PARD
Gas Test 12/30/2022 Approved JEFFREY PARD
SGSOV-Seismic Gas S/O Valve 1/5/2023 SGSOV Approved JEFFREY PARD
Service/Power Release 2/9/2023 Corrections Issued JEFFREY PARD
Service/Power Release 2/13/2023 Approved HENRY KIM
ELECTRICAL-Final 3/15/2023 Approved JEFFREY PARD
PLUMBING-Final 3/20/2023 Approved JEFFREY PARD
HVAC-Final 3/22/2023 Approved JEFFREY PARD
Final 3/29/2023 Not Ready for Inspection JEFFREY PARD
Green Building Final 3/29/2023 Not Ready for Inspection JEFFREY PARD
Smoke Detectors 3/29/2023 Not Ready for Inspection JEFFREY PARD
Final 3/31/2023 Not Ready for Inspection JEFFREY PARD
Green Building Final 3/31/2023 Not Ready for Inspection JEFFREY PARD
Smoke Detectors 3/31/2023 Not Ready for Inspection JEFFREY PARD
Final 4/4/2023 OK to Issue CofO JEFFREY PARD
Green Building Final 4/4/2023 Approved JEFFREY PARD
Smoke Detectors 4/4/2023 Approved JEFFREY PARD