1563 1/2 S SPAULDING AVE 90019

Certificate Information: 1563 1/2 S SPAULDING AVE 90019

Application / Permit
21010-20000-03538
Plan Check / Job No.
B21VN09190
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 32'-11" x 27'-8" ONE STORY ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(B) and LAMC 12.22 A.33(c)¹, (d)¹, and (g) WITH ROOFTOP DECK
Permit Issued
Issued on 3/8/2022
Issuing Office
West Los Angeles
Current Status
CofO Issued on 11/18/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/14/2021 APPLICANT
Assigned to Plan Check Engineer 7/29/2021 SELLA BENYAMIN
Corrections Issued 8/2/2021 SELLA BENYAMIN
Quality Review Completed 8/4/2021 OMID HEDAYAT
Building Plans Picked Up 8/5/2021 APPLICANT
Plan Check Approved 2/3/2022 SELLA BENYAMIN
Issued 3/8/2022 APPLICANT
CofO in Progress 11/7/2023 JOSE AVILA
Permit Finaled 11/18/2023 DEROLD HAUFF
CofO Issued 11/18/2023 DEROLD HAUFF
Permit Finaled 11/18/2023 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 9/13/2021 JEANIE LAM
Eng Process Fee Ord 176,300 Cleared 9/13/2021 JEANIE LAM
Sewer availability Cleared 9/13/2021 JEANIE LAM
Hydrant and Access approval Cleared 12/3/2021 MATTHEW CRAIG
Construction near power lines Cleared 12/13/2021 RIDWAN HARDY
Low Impact Development Cleared 1/20/2022 SARAH YOUSSEF
Roof/Waste drainage to street Cleared 1/21/2022 AMAAN MALIK

Contact Information

Contractor Da Only Inc; Lic. No.: 1073836-B 9320 S LA CIENEGA BLVD      INGLEWOOD, CA 90301
Engineer Boranian,, Paul Darian; Lic. No.: S5944 23261 BURBANK BL      WOODLAND HILLS, CA 91367

Inspector Information

DAVID WILLIAMS, (213) 202-3126 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 5/26/2022 Corrections Issued JOSE AVILA
METHANE-Barrier 5/26/2022 Corrections Issued JOSE AVILA
METHANE-Subgrade 5/26/2022 Corrections Issued JOSE AVILA
Footing/Foundation/Slab 6/1/2022 Corrections Issued JOSE AVILA
METHANE-Barrier 6/1/2022 Corrections Issued JOSE AVILA
METHANE-Subgrade 6/1/2022 Corrections Issued JOSE AVILA
Footing/Foundation/Slab 6/6/2022 Partial Approval JOSE AVILA
METHANE-Barrier 6/6/2022 Corrections Issued JOSE AVILA
METHANE-Subgrade 6/6/2022 Partial Approval JOSE AVILA
METHANE-Rough 7/5/2022 Approved JOSE AVILA
Underground Mechanical 7/11/2022 Approved JOSE AVILA
Deputy Methane Barrier 7/15/2022 Conditional Approval JOSE AVILA
METHANE-Barrier 7/18/2022 Approved JOSE AVILA
Footing/Foundation/Slab 7/25/2022 Approved JOSE AVILA
METHANE-Subgrade 7/25/2022 Approved JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 8/15/2022 Corrections Issued JOSE AVILA
Green Building Rough 8/15/2022 Not Ready for Inspection JOSE AVILA
Verify Sprinkler Sign Off 8/15/2022 Not Ready for Inspection JOSE AVILA
ELECTRICAL-Rough 9/9/2022 Approved JOSE AVILA
PLUMBING-Rough 9/9/2022 Approved JOSE AVILA
BUILDING-Rough-Frame 9/13/2022 Partial Approval JOSE AVILA
Green Building Rough 9/13/2022 Approved JOSE AVILA
HVAC-Rough 9/13/2022 Approved JOSE AVILA
Verify Sprinkler Sign Off 9/13/2022 Partial Inspection JOSE AVILA
Interior/Exterior Lathing 9/27/2022 Approved JOSE AVILA
Drywall Nailing 10/17/2022 Approved JOSE AVILA
Insulation 1/26/2023 Approved JOSE AVILA
Verify Sprinkler Sign Off 1/26/2023 Partial Inspection JOSE AVILA
Deputy Steel/Welding 1/30/2023 Conditional Approval JOSE AVILA
HVAC-Final 2/14/2023 Corrections Issued JOSE AVILA
PLUMBING-Final 2/14/2023 Approved JOSE AVILA
BUILDING-Rough-Frame 5/5/2023 Approved JOSE AVILA
Final 5/5/2023 Corrections Issued JOSE AVILA
Green Building Final 5/5/2023 Approved JOSE AVILA
SGSOV-Seismic Gas S/O Valve 5/5/2023 SGSOV Approved JOSE AVILA
Smoke Detectors 5/5/2023 Approved JOSE AVILA
Verify Sprinkler Sign Off 5/5/2023 Approved JOSE AVILA
ELECTRICAL-Final 6/28/2023 Corrections Issued JOSE AVILA
Service/Power Release 6/28/2023 Approved JOSE AVILA
Final 9/21/2023 Not Ready for Inspection JOSE AVILA
Final 11/6/2023 OK to Issue CofO JOSE AVILA