4793 N LOUISE AVE 91316
Certificate Information: 4793 N LOUISE AVE 91316
- Application / Permit
- 21010-20000-01707
- Plan Check / Job No.
- B21VN04154
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW (68'-0"x 50'-6") IRR SHAPE TWO-STORY SINGLE FAMILY DWELLING WITH ATTACHED 2- CAR GARAGE WITH BASEMENT. NFPA-13D AUTO FIRE SPRINKLER THROUGHOUT. WORK PER ENGINEER.
- Permit Issued
- Issued on 12/21/2021
- Issuing Office
- Valley
- Current Status
- CofO Issued on 10/13/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/8/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 4/15/2021 | TROY DEGUZMAN |
| Corrections Issued | 4/18/2021 | TROY DEGUZMAN |
| Quality Review Completed | 4/19/2021 | OMID HEDAYAT |
| Applicant returned to address corrections | 11/10/2021 | TROY DEGUZMAN |
| Applicant returned to address corrections | 11/29/2021 | TROY DEGUZMAN |
| Plan Check Approved | 12/15/2021 | TROY DEGUZMAN |
| Issued | 12/21/2021 | APPLICANT |
| CofO in Progress | 10/6/2023 | JON MCHUGH |
| Permit Finaled | 10/13/2023 | JOHN JANSON |
| CofO Issued | 10/13/2023 | JOHN JANSON |
| Permit Finaled | 10/13/2023 | JOHN JANSON |
Permit Application Clearance Information
| GPI Written Notices | Cleared | 4/17/2021 | TROY DEGUZMAN |
| Grading Pre-Inspection | Cleared | 4/17/2021 | TROY DEGUZMAN |
| Address approval | Cleared | 5/5/2021 | GABRIEL ROBLES |
| Eng Process Fee Ord 176,300 | Cleared | 5/25/2021 | GABRIEL ROBLES |
| Watercourse | Cleared | 5/25/2021 | GABRIEL ROBLES |
| Sewer availability | Cleared | 6/8/2021 | GABRIEL ROBLES |
| Hydrant and Access approval | Cleared | 8/13/2021 | MATTHEW CRAIG |
| Green Code | Cleared | 11/10/2021 | TROY DEGUZMAN |
| Low Impact Development | Cleared | 12/3/2021 | ANDRES COVARRUBIAS |
| Roof/Waste drainage to street | Cleared | 12/6/2021 | ABDULLAH SADOZAI |
Contact Information
| Contractor | E T Development Inc; Lic. No.: 994749-B | 7256 BELLAIRE AVENUE NORTH HOLLYWOOD, CA 91605 |
| Engineer | Yuzon,, Benigno S; Lic. No.: S3454 | 2511 PEACHWOOD PLACE WESTLAKE VILLAGE, CA 91361 |
| Geologist | Kruger,, Mark Otto; Lic. No.: EG2345 | 10120 NATIONAL BLVD LOS ANGELES, CA 90034 |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 1/24/2022 | Partial Approval | SEAN HAUPT |
| Special/Order Compliance | 2/5/2022 | Corrections Issued | GORDON ZUBER |
| Footing/Foundation/Slab | 2/7/2022 | Approved | SEAN HAUPT |
| Deputy Reinf. Concrete | 2/8/2022 | Partial Approval | SEAN HAUPT |
| Deputy Other (see comments) | 2/14/2022 | No Access for Inspection | PETER FOLLING |
| Excavation/Setback/Form/Re-Bar | 2/24/2022 | Approved | SEAN HAUPT |
| Footing/Foundation/Slab | 2/24/2022 | Approved | SEAN HAUPT |
| Deputy Reinf. Concrete | 3/7/2022 | Partial Approval | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 4/1/2022 | Approved | SEAN HAUPT |
| Footing/Foundation/Slab | 4/5/2022 | Approved | SEAN HAUPT |
| Deputy Reinf. Concrete | 4/6/2022 | Partial Approval | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 4/13/2022 | Approved | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 4/21/2022 | Approved | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 7/11/2022 | Approved | VINCENT HANLEY |
| HVAC-Rough | 7/11/2022 | Approved | VINCENT HANLEY |
| PLUMBING-Rough | 7/11/2022 | Approved | VINCENT HANLEY |
| Wood Frame | 7/11/2022 | Partial Approval | VINCENT HANLEY |
| Interior/Exterior Lathing | 7/21/2022 | Not Ready for Inspection | JEFFREY BULL |
| BUILDING-Rough-Frame | 7/28/2022 | Approved | SEAN HAUPT |
| Green Building Rough | 7/28/2022 | Approved | SEAN HAUPT |
| Interior/Exterior Lathing | 7/28/2022 | Approved | SEAN HAUPT |
| Verify Sprinkler Sign Off | 7/28/2022 | Approved | SEAN HAUPT |
| Insulation | 8/3/2022 | Conditional Approval | JUSTIN HAWLEY |
| Drywall Nailing | 8/15/2022 | Approved | MORRIS JACKSON |
| Shower Pan | 8/15/2022 | Approved | MORRIS JACKSON |
| Interior/Exterior Lathing | 8/24/2022 | Approved | SEAN HAUPT |
| ELECTRICAL-Final | 4/19/2023 | Not Ready for Inspection | JON MCHUGH |
| ELECTRICAL-Final | 5/1/2023 | Not Ready for Inspection | JON MCHUGH |
| PLUMBING-Final | 5/1/2023 | Approved | JON MCHUGH |
| ELECTRICAL-Final | 5/16/2023 | Approved | JON MCHUGH |
| HVAC-Final | 5/16/2023 | Approved | JON MCHUGH |
| Service/Power Release | 5/31/2023 | Approved | JON MCHUGH |
| Final | 10/10/2023 | OK to Issue CofO | JON MCHUGH |
| Green Building Final | 10/10/2023 | Approved | JON MCHUGH |
| Reinforced Concrete Frame | 10/10/2023 | Approved | JON MCHUGH |
| SGSOV-Seismic Gas S/O Valve | 10/10/2023 | SGSOV Approved | JON MCHUGH |
| Smoke Detectors | 10/10/2023 | Approved | JON MCHUGH |