1666 N SAN ONOFRE DR 90272
Certificate Information: 1666 N SAN ONOFRE DR 90272
- Application / Permit
- 21010-20000-01021
- Plan Check / Job No.
- B21VN02477
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Recreation Room
- Work Description
- (N) 1-STORY DETACHED RECREATION ROOM (IRR 21'-4" X 15'- 9 1/2")
- Permit Issued
- Issued on 10/7/2021
- Issuing Office
- Current Status
- CofO Issued on 1/3/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/12/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 3/18/2021 | NILOOFAR MEHRAIN |
| Corrections Issued | 3/20/2021 | NILOOFAR MEHRAIN |
| Quality Review Completed | 3/23/2021 | CHON CHIO KUO |
| Applicant returned to address corrections | 6/9/2021 | NILOOFAR MEHRAIN |
| Plan Check Approved | 7/7/2021 | NILOOFAR MEHRAIN |
| Issued | 10/7/2021 | APPLICANT |
| CofO in Progress | 12/29/2022 | JUAN VALENZUELA |
| Permit Finaled | 1/3/2023 | DANIEL ORRANTE |
| CofO Issued | 1/3/2023 | DANIEL ORRANTE |
| Permit Finaled | 1/3/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| ZA Case | Cleared | 6/10/2021 | LAUREN PADICK |
| Grading Pre-Inspection | Cleared | 6/15/2021 | BRIAN MILLER |
| Sewer availability | Cleared | 6/18/2021 | DINAH GARIN |
| Roof/Waste drainage to street | Cleared | 6/29/2021 | DINAH GARIN |
| Eng Process Fee Ord 176,300 | Cleared | 7/20/2021 | DINAH GARIN |
| Miscellaneous | Cleared | 10/5/2021 | JENSON LEE |
Contact Information
| Contractor | Sound Structures Inc; Lic. No.: 923028-B | 21017 HILLSIDE DRIVE TOPANGA, CA 90290 |
| Engineer | Koma,, Shahram Javadi; Lic. No.: C69497 | 23241 VENTURA BLVD 300 WOODLAND HILLS, CA 91364 |
Inspector Information
| KEVIN SARGSYAN, (310) 914-3889 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Piling/Pier/Caisson | 10/13/2021 | Corrections Issued | JUAN VALENZUELA |
| Pre-Inspection | 10/13/2021 | Partial Inspection | JUAN VALENZUELA |
| Deputy Reinf. Concrete | 10/14/2021 | Conditional Approval | JUAN VALENZUELA |
| Excavation/Setback/Form/Re-Bar | 10/19/2021 | Partial Approval | JUAN VALENZUELA |
| Piling/Pier/Caisson | 10/19/2021 | Partial Approval | JUAN VALENZUELA |
| Deputy Other (see comments) | 10/22/2021 | Conditional Approval | JUAN VALENZUELA |
| Footing/Foundation/Slab | 11/29/2021 | Partial Approval | BRENDAN LOONEY |
| Masonry Wall/Backfill | 12/10/2021 | Partial Approval | JUAN VALENZUELA |
| Footing/Foundation/Slab | 1/6/2022 | Approved | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 2/11/2022 | Partial Approval | JUAN VALENZUELA |
| Floor/Roof Diaphrgm/Shear Wall | 2/24/2022 | Approved | JUAN VALENZUELA |
| Green Building Rough | 2/24/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| Verify Sprinkler Sign Off | 2/24/2022 | Corrections Issued | JUAN VALENZUELA |
| Interior/Exterior Lathing | 2/28/2022 | Approved | JOHN KIDWELL |
| ELECTRICAL-Rough | 3/16/2022 | Approved | JUAN VALENZUELA |
| HVAC-Rough | 3/16/2022 | Approved | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 3/21/2022 | Corrections Issued | JUAN VALENZUELA |
| Green Building Rough | 3/21/2022 | Approved | JUAN VALENZUELA |
| Verify Sprinkler Sign Off | 3/21/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 4/1/2022 | Approved | JUAN VALENZUELA |
| Verify Sprinkler Sign Off | 4/1/2022 | Approved | JUAN VALENZUELA |
| Drywall Nailing | 4/6/2022 | Approved | JOHN KIDWELL |
| Green Building Final | 8/11/2022 | Approved | JUAN VALENZUELA |
| Smoke Detectors | 8/11/2022 | Approved | JUAN VALENZUELA |
| ELECTRICAL-Final | 10/26/2022 | Approved | JUAN VALENZUELA |
| PLUMBING-Final | 10/26/2022 | Approved | JUAN VALENZUELA |
| SGSOV-Seismic Gas S/O Valve | 10/26/2022 | SGSOV Approved | JUAN VALENZUELA |
| Service/Power Release | 10/26/2022 | Approved | JUAN VALENZUELA |
| Final | 12/29/2022 | OK to Issue CofO | JUAN VALENZUELA |