976-976 1/2 N EVERETT ST 90026
Certificate Information: 976-976 1/2 N EVERETT ST 90026
- Application / Permit
- 21010-10000-06874
- Plan Check / Job No.
- B21LA24360
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- NEW 48'-9"X38' 3-STORY DUPLEX 4008 SF WITH (2) ATTACHED 2-CAR GARAGES 782 SF AT REAR OF LOT. 2 OF 2
- Permit Issued
- Issued on 6/8/2023
- Issuing Office
- Metro
- Current Status
- CofO Issued on 11/21/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/29/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 1/27/2022 | CHUNG-WEN CHUANG |
| Corrections Issued | 2/8/2022 | CHUNG-WEN CHUANG |
| Quality Review Completed | 2/18/2022 | TEODORO DIAZ RODRIGUEZ |
| Building Plans Picked Up | 2/28/2022 | APPLICANT |
| Applicant returned to address corrections | 5/24/2023 | CHUNG-WEN CHUANG |
| Plan Check Approved | 5/25/2023 | CHUNG-WEN CHUANG |
| Issued | 6/8/2023 | APPLICANT |
| CofO in Progress | 11/20/2025 | HAMIK HARTOUNIAN |
| Permit Finaled | 11/21/2025 | DEROLD HAUFF |
| CofO Issued | 11/21/2025 | DEROLD HAUFF |
| Permit Finaled | 11/21/2025 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 3/17/2022 | JEANETTE VONG |
| Permit | Cleared | 3/17/2022 | JEANETTE VONG |
| Eng Process Fee Ord 176,300 | Cleared | 3/30/2022 | JEANETTE VONG |
| Sewer availability | Cleared | 3/30/2022 | JEANETTE VONG |
| Trees in Parkway | Cleared | 5/19/2022 | ADALBERTO VERA |
| "Q" conditions | Cleared | 7/21/2022 | ANACANY HURTADO |
| Frnt yard landscape/Water mgmt | Cleared | 7/21/2022 | ANACANY HURTADO |
| Hydrant and Access approval | Cleared | 10/13/2022 | KURT CORRAL |
| Low Impact Development | Cleared | 11/23/2022 | ROGELIO CORTES |
| Roof/Waste drainage to street | Cleared | 11/29/2022 | THAN WIN |
| GPI Written Notices | Cleared | 5/25/2023 | CHUNG-WEN CHUANG |
| Grading Pre-Inspection | Cleared | 5/25/2023 | CHUNG-WEN CHUANG |
Contact Information
| Contractor | Lajoma Construction Inc; Lic. No.: 864461-B | 838 E 93RD ST LOS ANGELES, CA 90002 |
| Engineer | Nuno,, Arnulfo; Lic. No.: C88425 | 7057 DWIGHT WAY SAN BERNARDINO, CA 92404 |
Inspector Information
| HAMIK HARTOUNIAN, (213) 202-3275 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 6/26/2024 | Corrections Issued | HAMIK HARTOUNIAN |
| Excavation/Setback/Form/Re-Bar | 10/22/2024 | Corrections Issued | HAMIK HARTOUNIAN |
| METHANE-Barrier | 10/22/2024 | Corrections Issued | HAMIK HARTOUNIAN |
| Underground Mechanical | 10/22/2024 | Partial Inspection | HAMIK HARTOUNIAN |
| Excavation/Setback/Form/Re-Bar | 11/20/2024 | Approved | LUIS CASTRO |
| Footing/Foundation/Slab | 11/20/2024 | Approved | LUIS CASTRO |
| METHANE-Barrier | 11/20/2024 | Approved | LUIS CASTRO |
| METHANE-Subgrade | 11/20/2024 | Approved | LUIS CASTRO |
| Deputy Reinf. Concrete | 11/21/2024 | Conditional Approval | HAMIK HARTOUNIAN |
| Deputy Wood Construction | 4/22/2025 | Conditional Approval | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/22/2025 | Partial Approval | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 4/22/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 4/25/2025 | Partial Approval | HAMIK HARTOUNIAN |
| HVAC-Rough | 4/25/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 5/9/2025 | Approved | HAMIK HARTOUNIAN |
| Green Building Rough | 5/9/2025 | Approved | HAMIK HARTOUNIAN |
| HVAC-Rough | 5/9/2025 | Approved | HAMIK HARTOUNIAN |
| Interior/Exterior Lathing | 5/9/2025 | Partial Approval | HAMIK HARTOUNIAN |
| METHANE-Rough | 5/9/2025 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 5/9/2025 | Approved | HAMIK HARTOUNIAN |
| Verify Sprinkler Sign Off | 5/9/2025 | Approved | HAMIK HARTOUNIAN |
| Insulation | 5/20/2025 | Approved | ALEX COLIN |
| Interior/Exterior Lathing | 5/20/2025 | Partial Approval | ALEX COLIN |
| Drywall Nailing | 5/30/2025 | Approved | ALEX COLIN |
| HVAC-Final | 10/17/2025 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Final | 10/17/2025 | Approved | HAMIK HARTOUNIAN |
| ELECTRICAL-Final | 10/20/2025 | Approved | ROBERT CORNELL |
| Service/Power Release | 10/20/2025 | Approved | ROBERT CORNELL |
| Final | 11/4/2025 | Corrections Issued | HAMIK HARTOUNIAN |
| Green Building Final | 11/4/2025 | Approved | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 11/4/2025 | SGSOV No Gas | HAMIK HARTOUNIAN |
| Smoke Detectors | 11/4/2025 | Approved | HAMIK HARTOUNIAN |
| Final | 11/14/2025 | Partial Inspection | HAMIK HARTOUNIAN |
| Final | 11/19/2025 | OK to Issue CofO | HAMIK HARTOUNIAN |