1309 1/2 W GAGE AVE 90044

Certificate Information: 1309 1/2 W GAGE AVE 90044

Application / Permit
21010-10000-06788
Plan Check / Job No.
B21LA24206
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW DETACHED ADU
Permit Issued
Issued on 7/26/2023
Issuing Office
West Los Angeles
Current Status
CofO Issued on 7/29/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/31/2021 APPLICANT
Assigned to Plan Check Engineer 1/10/2022 JESSE JIMENEZ
Corrections Issued 1/12/2022 JESSE JIMENEZ
Building Plans Picked Up 1/14/2022 APPLICANT
Plan Check Approved 7/11/2023 FERNANDO FLORES
Issued 7/26/2023 APPLICANT
CofO in Progress 7/29/2024 JOSE MACIAS
Permit Finaled 7/29/2024 DEROLD HAUFF
CofO Issued 7/29/2024 DEROLD HAUFF
Permit Finaled 7/29/2024 DEROLD HAUFF

Permit Application Clearance Information

Construction near power lines Cleared 3/17/2022 RIDWAN HARDY
Address approval Cleared 1/12/2023 WALLIE JONG
Low Impact Development Cleared 4/7/2023 TOMMY YIN
Tenant Habitability Plan Cleared 4/7/2023 RICARDO BOHORQUEZ
Eng Process Fee Ord 176,300 Cleared 4/11/2023 WALLIE JONG
Sewer availability Cleared 4/11/2023 WALLIE JONG
Roof/Waste drainage to street Cleared 4/27/2023 WALLIE JONG

Contact Information

Contractor Owner-Builder       ,
Engineer Lu,, Yi; Lic. No.: S5678 P O BOX 2754      PALOS VERDES PENINSULA, CA 90274

Inspector Information

BARRY HACHE, (213) 202-9851 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 10/26/2023 Partial Inspection CRAIG DAVIS
Excavation/Setback/Form/Re-Bar 11/8/2023 Not Ready for Inspection CRAIG DAVIS
Footing/Foundation/Slab 11/8/2023 Partial Inspection CRAIG DAVIS
Footing/Foundation/Slab 11/9/2023 Approved CRAIG DAVIS
Floor/Roof Diaphrgm/Shear Wall 12/4/2023 Partial Approval CRAIG DAVIS
PLUMBING-Rough 12/4/2023 Corrections Issued CRAIG DAVIS
Wood Frame 12/4/2023 Partial Approval CRAIG DAVIS
ELECTRICAL-Rough 12/8/2023 Not Ready for Inspection DAVID FEILER
Floor/Roof Diaphrgm/Shear Wall 12/8/2023 Not Ready for Inspection DAVID FEILER
PLUMBING-Rough 12/8/2023 Not Ready for Inspection DAVID FEILER
Sewer 12/8/2023 Partial Approval DAVID FEILER
Wood Frame 12/8/2023 Corrections Issued DAVID FEILER
ELECTRICAL-Rough 12/18/2023 Partial Approval CRAIG DAVIS
Floor/Roof Diaphrgm/Shear Wall 12/18/2023 Approved CRAIG DAVIS
PLUMBING-Rough 12/18/2023 Approved CRAIG DAVIS
Sewer 12/18/2023 Partial Approval CRAIG DAVIS
Wood Frame 12/18/2023 Partial Approval CRAIG DAVIS
ELECTRICAL-Rough 12/19/2023 No Access for Inspection ENRIQUE MIRELES
Floor/Roof Diaphrgm/Shear Wall 12/19/2023 No Access for Inspection ENRIQUE MIRELES
Masonry Wall/Backfill 12/19/2023 No Access for Inspection ENRIQUE MIRELES
PLUMBING-Rough 12/19/2023 No Access for Inspection ENRIQUE MIRELES
Sewer 12/19/2023 No Access for Inspection ENRIQUE MIRELES
Wood Frame 12/19/2023 No Access for Inspection ENRIQUE MIRELES
Insulation 1/31/2024 Corrections Issued RONNIE MINDANAO
ELECTRICAL-Rough 2/12/2024 Corrections Issued SABAS ALONSO
Floor/Roof Diaphrgm/Shear Wall 2/12/2024 Not Ready for Inspection SABAS ALONSO
Insulation 2/12/2024 Not Ready for Inspection SABAS ALONSO
PLUMBING-Rough 2/12/2024 Approved SABAS ALONSO
Sewer 2/12/2024 Corrections Issued SABAS ALONSO
Wood Frame 2/12/2024 Corrections Issued SABAS ALONSO
BUILDING-Rough-Frame 2/20/2024 Approved BRENDAN MORELLI
ELECTRICAL-Rough 2/20/2024 Approved BRENDAN MORELLI
Floor/Roof Diaphrgm/Shear Wall 2/20/2024 Approved BRENDAN MORELLI
Green Building Rough 2/20/2024 Approved BRENDAN MORELLI
HVAC-Rough 2/20/2024 Approved BRENDAN MORELLI
Insulation 2/20/2024 Approved BRENDAN MORELLI
Sewer 2/20/2024 Not Ready for Inspection BRENDAN MORELLI
Verify Sprinkler Sign Off 2/20/2024 Approved BRENDAN MORELLI
Drywall Nailing 3/5/2024 Approved ALEJANDRO DE ARTOLA
Interior/Exterior Lathing 3/5/2024 Corrections Issued ALEJANDRO DE ARTOLA
Interior/Exterior Lathing 3/12/2024 Partial Approval JOSH MEISTER
Sewer 3/12/2024 No Access for Inspection JOSH MEISTER
Final 5/13/2024 Corrections Issued CRAIG DAVIS
Green Building Final 5/13/2024 Corrections Issued CRAIG DAVIS
SGSOV-Seismic Gas S/O Valve 5/13/2024 SGSOV Not Ready CRAIG DAVIS
Service/Power Release 5/13/2024 Corrections Issued CRAIG DAVIS
Smoke Detectors 5/13/2024 Approved CRAIG DAVIS
SGSOV-Seismic Gas S/O Valve 5/21/2024 SGSOV Not Ready CRAIG DAVIS
Pre-Inspection 5/24/2024 Corrections Issued CRAIG DAVIS
Final 6/4/2024 Partial Inspection CRAIG DAVIS
Green Building Final 6/4/2024 Partial Approval CRAIG DAVIS
SGSOV-Seismic Gas S/O Valve 6/4/2024 SGSOV Not Ready CRAIG DAVIS
Service/Power Release 6/4/2024 Partial Inspection CRAIG DAVIS
Final 6/27/2024 Corrections Issued DAVID FEILER
Green Building Final 6/27/2024 Not Ready for Inspection DAVID FEILER
SGSOV-Seismic Gas S/O Valve 6/27/2024 SGSOV Not Ready DAVID FEILER
Service/Power Release 6/27/2024 Not Ready for Inspection DAVID FEILER
Final 7/22/2024 Corrections Issued JOSE MACIAS
Green Building Final 7/22/2024 Approved JOSE MACIAS
SGSOV-Seismic Gas S/O Valve 7/22/2024 SGSOV Approved JOSE MACIAS
Service/Power Release 7/22/2024 Corrections Issued JOSE MACIAS
Sewer 7/22/2024 Approved JOSE MACIAS
Final 7/26/2024 OK to Issue CofO JOSE MACIAS
Service/Power Release 7/26/2024 Approved JOSE MACIAS