2217 S GLYNDON AVE 90291

Certificate Information: 2217 S GLYNDON AVE 90291

Application / Permit
21010-10000-05625
Plan Check / Job No.
B21LA20206
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
(N) 2-STORY ACCESSORY DWELLING UNIT PER LAMC 12.22.A.33.(c)-(d)
Permit Issued
Issued on 8/7/2023
Issuing Office
Current Status
CofO Issued on 6/2/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 11/1/2021 APPLICANT
Assigned to Plan Check Engineer 11/18/2021 STARR CHEN
Corrections Issued 11/26/2021 STARR CHEN
Quality Review Completed 12/2/2021 TEODORO DIAZ RODRIGUEZ
Building Plans Picked Up 12/7/2021 APPLICANT
Applicant returned to address corrections 1/11/2023 STARR CHEN
Plan Check Approved 3/29/2023 DANIEL YIP
Issued 8/7/2023 APPLICANT
CofO in Progress 6/2/2026 RUBEN RIVAS
Permit Finaled 6/2/2026 RICHARD STEINBACH
CofO Issued 6/2/2026 RICHARD STEINBACH
Permit Finaled 6/2/2026 RICHARD STEINBACH

Permit Application Clearance Information

Address approval Cleared 12/20/2021 DENNIS BRAGIN
Roof/Waste drainage to street Cleared 12/20/2021 DENNIS BRAGIN
Specific Plan Cleared 3/3/2022 PEDRO AYALA
Construction near power lines Cleared 11/29/2022 RIDWAN HARDY
Eng Process Fee Ord 176,300 Cleared 2/14/2023 SAUL GARCIA
Sewer availability Cleared 2/14/2023 SAUL GARCIA

Contact Information

Contractor Pacific Coast Environments; Lic. No.: 616213-B 5425 E MEZZANINE WAY      LONG BEACH, CA 90808

Inspector Information

RUBEN RIVAS, (310) 914-3981 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 1/16/2024 Approved TEMISTOCLES CAAL
Excavation/Setback/Form/Re-Bar 1/19/2024 Conditional Approval JESUS RODRIGUEZ
Floor/Roof Diaphrgm/Shear Wall 3/6/2024 Corrections Issued HERBERT GIRON
Footing/Foundation/Slab 3/6/2024 Approved HERBERT GIRON
Floor/Roof Diaphrgm/Shear Wall 3/26/2024 Partial Approval HERBERT GIRON
Underground Mechanical 3/26/2024 Partial Approval HERBERT GIRON
Floor/Roof Diaphrgm/Shear Wall 5/3/2024 Corrections Issued TEMISTOCLES CAAL
Floor/Roof Diaphrgm/Shear Wall 5/7/2024 Corrections Issued TEMISTOCLES CAAL
ELECTRICAL-Rough 5/10/2024 Corrections Issued HERBERT GIRON
Floor/Roof Diaphrgm/Shear Wall 5/10/2024 Approved HERBERT GIRON
PLUMBING-Rough 5/10/2024 Approved HERBERT GIRON
Sewer 5/10/2024 Approved HERBERT GIRON
ELECTRICAL-Rough 6/14/2024 Approved HERBERT GIRON
HVAC-Rough 6/14/2024 Corrections Issued HERBERT GIRON
BUILDING-Rough-Frame 8/5/2024 Corrections Issued HERBERT GIRON
Green Building Rough 8/5/2024 Approved HERBERT GIRON
HVAC-Rough 8/5/2024 Approved HERBERT GIRON
Interior/Exterior Lathing 8/5/2024 Partial Approval HERBERT GIRON
Verify Sprinkler Sign Off 8/5/2024 Corrections Issued HERBERT GIRON
Shower Pan 8/7/2024 Approved HERBERT GIRON
BUILDING-Rough-Frame 8/21/2024 Conditional Approval HERBERT GIRON
Insulation 8/21/2024 Approved HERBERT GIRON
Drywall Nailing 8/27/2024 Approved ARAM AVEDISIAN
ELECTRICAL-Final 9/16/2024 Corrections Issued HERBERT GIRON
Interior/Exterior Lathing 9/16/2024 Approved HERBERT GIRON
ELECTRICAL-Final 6/16/2025 Corrections Issued JESUS RODRIGUEZ
HVAC-Final 6/16/2025 Corrections Issued JESUS RODRIGUEZ
PLUMBING-Final 6/16/2025 Approved JESUS RODRIGUEZ
Smoke Detectors 6/16/2025 Approved JESUS RODRIGUEZ
BUILDING-Rough-Frame 1/27/2026 Approved RUBEN RIVAS
Final 1/27/2026 Corrections Issued RUBEN RIVAS
Green Building Final 1/27/2026 Approved RUBEN RIVAS
SGSOV-Seismic Gas S/O Valve 1/27/2026 SGSOV Approved RUBEN RIVAS
Service/Power Release 1/27/2026 Not Ready for Inspection RUBEN RIVAS
Final 5/27/2026 OK to Issue CofO RUBEN RIVAS
Service/Power Release 5/27/2026 Approved RUBEN RIVAS