7905 N FALLBROOK AVE 91304

Certificate Information: 7905 N FALLBROOK AVE 91304

Application / Permit
21010-10000-01812
Plan Check / Job No.
B21LA06770
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
ePlan Proposed 1-story detached ADU 31'x21' per ordinance. “The LID clearance has been deferred. Approval for LID requirements shall be obtained from LASAN prior to the issuance of the Certificate of Occupancy.”
Permit Issued
Issued on 6/2/2022
Issuing Office
Current Status
CofO Issued on 4/21/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/13/2021 APPLICANT
Assigned to Plan Check Engineer 4/15/2021 MICHAEL LOPEZ
Corrections Issued 4/15/2021 MICHAEL LOPEZ
Applicant returned to address corrections 5/11/2022 MICHAEL LOPEZ
Applicant returned to address corrections 5/12/2022 MICHAEL LOPEZ
Plan Check Approved 5/25/2022 MICHAEL LOPEZ
Issued 6/2/2022 APPLICANT
CofO in Progress 3/17/2023 CHRIS CHRISTENSEN
Permit Finaled 4/21/2023 JOHN JANSON
CofO Issued 4/21/2023 JOHN JANSON
Permit Finaled 4/21/2023 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 5/14/2021 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 5/17/2021 CARLOS AGUILERA
Sewer availability Cleared 5/18/2021 CARLOS AGUILERA
Hydrant and Access approval Cleared 2/19/2022 LAURINDA MEADE
Roof/Waste drainage to street Cleared 3/9/2022 CARLOS AGUILERA

Contact Information

Contractor Owner-Builder       ,

Inspector Information

JEFFREY HARTLINE, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI
CHRIS CHRISTENSEN, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 7/21/2022 Partial Approval CHRIS CHRISTENSEN
Underground Mechanical 7/21/2022 Partial Approval CHRIS CHRISTENSEN
Footing/Foundation/Slab 7/26/2022 Approved CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 9/12/2022 Approved TROY SANDERS
Green Building Rough 9/12/2022 Not Ready for Inspection TROY SANDERS
Underground Mechanical 9/12/2022 Approved TROY SANDERS
Verify Sprinkler Sign Off 9/12/2022 Not Ready for Inspection TROY SANDERS
BUILDING-Rough-Frame 10/3/2022 Partial Approval CHRIS CHRISTENSEN
ELECTRICAL-Rough 10/3/2022 Approved CHRIS CHRISTENSEN
Green Building Rough 10/3/2022 Not Ready for Inspection CHRIS CHRISTENSEN
HVAC-Rough 10/3/2022 Approved CHRIS CHRISTENSEN
PLUMBING-Rough 10/3/2022 Approved CHRIS CHRISTENSEN
Verify Sprinkler Sign Off 10/3/2022 Not Ready for Inspection CHRIS CHRISTENSEN
Interior/Exterior Lathing 10/11/2022 Corrections Issued JESUS PINEDA
Drywall Nailing 10/20/2022 Approved JUSTIN HAWLEY
Green Building Rough 10/20/2022 Approved JUSTIN HAWLEY
Insulation 10/20/2022 Approved JUSTIN HAWLEY
Interior/Exterior Lathing 10/20/2022 Partial Approval JUSTIN HAWLEY
Interior/Exterior Lathing 10/31/2022 Approved MORRIS JACKSON
Shower Pan 10/31/2022 Approved MORRIS JACKSON
BUILDING-Rough-Frame 2/6/2023 Approved CHRIS CHRISTENSEN
ELECTRICAL-Final 2/6/2023 Approved CHRIS CHRISTENSEN
Final 2/6/2023 Corrections Issued CHRIS CHRISTENSEN
Green Building Final 2/6/2023 Approved CHRIS CHRISTENSEN
HVAC-Final 2/6/2023 Approved CHRIS CHRISTENSEN
PLUMBING-Final 2/6/2023 Approved CHRIS CHRISTENSEN
SGSOV-Seismic Gas S/O Valve 2/6/2023 SGSOV Approved CHRIS CHRISTENSEN
Service/Power Release 2/6/2023 Not Ready for Inspection CHRIS CHRISTENSEN
Smoke Detectors 2/6/2023 Approved CHRIS CHRISTENSEN
Verify Sprinkler Sign Off 2/6/2023 Approved CHRIS CHRISTENSEN
Final 3/16/2023 OK to Issue CofO CHRIS CHRISTENSEN
Service/Power Release 3/16/2023 Approved CHRIS CHRISTENSEN