1727 N AVENUE 46 90041
Certificate Information: 1727 N AVENUE 46 90041
- Application / Permit
- 21010-10000-00019
- Plan Check / Job No.
- B21LA00069
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 2 STORY SFD WITH ATTACHED GARAGE (FRONT)
- Permit Issued
- Issued on 3/31/2022
- Issuing Office
- Metro
- Current Status
- CofO Issued on 8/13/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/11/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 2/4/2021 | STARR CHEN |
| Corrections Issued | 2/5/2021 | STARR CHEN |
| Quality Review Completed | 2/11/2021 | ALLEN MANALANSAN |
| Applicant returned to address corrections | 8/9/2021 | STARR CHEN |
| Applicant returned to address corrections | 12/22/2021 | STARR CHEN |
| Plan Check Approved | 2/24/2022 | STARR CHEN |
| Issued | 3/31/2022 | APPLICANT |
| Building Plans Picked Up | 4/7/2022 | APPLICANT |
| CofO in Progress | 7/26/2023 | CRAIG VAUGHAN |
| Permit Finaled | 8/13/2023 | DEROLD HAUFF |
| CofO Issued | 8/13/2023 | DEROLD HAUFF |
| Permit Finaled | 8/13/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 8/9/2021 | RENZ SORIANO |
| Highway dedication | Cleared | 8/9/2021 | RENZ SORIANO |
| Permit | Cleared | 8/9/2021 | RENZ SORIANO |
| Eng Process Fee Ord 176,300 | Cleared | 8/10/2021 | RENZ SORIANO |
| Sewer availability | Cleared | 8/10/2021 | RENZ SORIANO |
| Hydrant and Access approval | Cleared | 9/30/2021 | KURT CORRAL |
| Trees in Parkway | Cleared | 10/12/2021 | ADALBERTO VERA |
| Low Impact Development | Cleared | 12/16/2021 | NICK RAYGOZA |
| Roof/Waste drainage to street | Cleared | 12/20/2021 | JEANETTE VONG |
| GPI Written Notices | Cleared | 2/24/2022 | STARR CHEN |
| Grading Pre-Inspection | Cleared | 2/24/2022 | STARR CHEN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Torres,, Efren Santos; Lic. No.: S2340 | 16003 S INDIAN CREEK RD CERRITOS, CA 90701 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 5/13/2022 | Partial Approval | CRAIG VAUGHAN |
| Excavation/Setback/Form/Re-Bar | 5/19/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| Footing/Foundation/Slab | 5/19/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| Excavation/Setback/Form/Re-Bar | 5/20/2022 | Partial Approval | OSVALDO PARAMO |
| Floor/Roof Diaphrgm/Shear Wall | 8/5/2022 | Partial Approval | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 8/12/2022 | Not Ready for Inspection | ALIZAH MAYAGOITIA |
| Sewer | 8/12/2022 | Approved | ALIZAH MAYAGOITIA |
| Underground Mechanical | 8/12/2022 | Partial Approval | ALIZAH MAYAGOITIA |
| ELECTRICAL-Rough | 8/19/2022 | Corrections Issued | CRAIG VAUGHAN |
| PLUMBING-Rough | 8/19/2022 | Approved | CRAIG VAUGHAN |
| Underground Mechanical | 8/19/2022 | Partial Approval | CRAIG VAUGHAN |
| Wood Frame | 8/19/2022 | Approved | CRAIG VAUGHAN |
| Insulation | 8/31/2022 | Approved | BRIAN SULLIVAN |
| Interior/Exterior Lathing | 8/31/2022 | Partial Approval | BRIAN SULLIVAN |
| Drywall Nailing | 9/12/2022 | Approved | SCOTT FINNILA |
| Interior/Exterior Lathing | 9/12/2022 | Partial Inspection | SCOTT FINNILA |
| Shower Pan | 9/12/2022 | Corrections Issued | SCOTT FINNILA |
| Shower Pan | 9/30/2022 | Approved | KATHRYN BUTTERWORTH |
| BUILDING-Rough-Frame | 2/10/2023 | Conditional Approval | CRAIG VAUGHAN |
| Final | 2/10/2023 | Corrections Issued | CRAIG VAUGHAN |
| Footing/Foundation/Slab | 2/10/2023 | Approved | CRAIG VAUGHAN |
| Gas Test | 2/10/2023 | Approved | CRAIG VAUGHAN |
| Green Building Final | 2/10/2023 | Approved | CRAIG VAUGHAN |
| Green Building Rough | 2/10/2023 | Approved | CRAIG VAUGHAN |
| HVAC-Final | 2/10/2023 | Approved | CRAIG VAUGHAN |
| SGSOV-Seismic Gas S/O Valve | 2/10/2023 | SGSOV Not Ready | CRAIG VAUGHAN |
| Service/Power Release | 2/10/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| Smoke Detectors | 2/10/2023 | Corrections Issued | CRAIG VAUGHAN |
| Verify Sprinkler Sign Off | 2/10/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 6/14/2023 | Approved | BRIAN SULLIVAN |
| Final | 6/14/2023 | Corrections Issued | BRIAN SULLIVAN |
| SGSOV-Seismic Gas S/O Valve | 6/14/2023 | SGSOV Approved | BRIAN SULLIVAN |
| Service/Power Release | 6/14/2023 | Not Ready for Inspection | BRIAN SULLIVAN |
| Smoke Detectors | 6/14/2023 | Approved | BRIAN SULLIVAN |
| Verify Sprinkler Sign Off | 6/14/2023 | Approved | BRIAN SULLIVAN |
| Final | 7/17/2023 | No Access for Inspection | CRAIG VAUGHAN |
| Service/Power Release | 7/17/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| Final | 7/25/2023 | OK to Issue CofO | CRAIG VAUGHAN |
| Service/Power Release | 7/25/2023 | Approved | CRAIG VAUGHAN |