1045 S BURNSIDE AVE 90019
Certificate Information: 1045 S BURNSIDE AVE 90019
- Application / Permit
- 20047-30000-01444
- Plan Check / Job No.
- B20WL03816
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW POOL PER STD. PLAN #268 AT REAR OF THE LOT. "COMPLY WITH DEPARTMENT ORDER effective date 10/13/2016. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE".
- Permit Issued
- Issued on 11/8/2020
- Issuing Office
- Current Status
- CofO Issued on 6/9/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/2/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 9/4/2020 | JAHANSHAH POURHASSAN |
| Corrections Issued | 9/7/2020 | JAHANSHAH POURHASSAN |
| Plan Check Approved | 10/29/2020 | RICHARD GARCIA |
| Issued | 11/8/2020 | APPLICANT |
| Building Plans Picked Up | 11/10/2020 | APPLICANT |
| CofO in Progress | 5/21/2021 | JOSEPH MCGARRY |
| Permit Finaled | 6/9/2021 | DEROLD HAUFF |
| CofO Issued | 6/9/2021 | DEROLD HAUFF |
| Permit Finaled | 6/9/2021 | DEROLD HAUFF |
Permit Application Clearance Information
| HPOZ | Cleared | 10/15/2020 | CHRISTINA PARK |
Contact Information
| Contractor | Botanica Landscape Inc; Lic. No.: 711054-B | 6237 WEST 83RD PLACE LOS ANGELES, CA 90045 |
| Engineer | Bongolan,, Resur G; Lic. No.: L8173 | 2139 PINECREST DR ALTADENA, CA 91001 |
Inspector Information
| RONNIE MINDANAO, (213) 202-3252 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 11/24/2020 | Partial Inspection | SCOTT FINNILA |
| Excavation/Setback/Form/Re-Bar | 12/11/2020 | Approved | JOSEPH MCGARRY |
| Grounding or Bonding | 12/11/2020 | Partial Approval | JOSEPH MCGARRY |
| Pool Piping | 12/11/2020 | Approved | JOSEPH MCGARRY |
| Pre-Gunite | 12/11/2020 | Conditional Approval | JOSEPH MCGARRY |
| Rough-Electrical | 12/11/2020 | Not Ready for Inspection | JOSEPH MCGARRY |
| Gas Piping or Gas Test | 1/27/2021 | Approved | JOSEPH MCGARRY |
| Rough-Electrical | 1/27/2021 | Approved | JOSEPH MCGARRY |
| Grounding or Bonding | 2/8/2021 | Approved | SCOTT FINNILA |
| ELECTRICAL-Final | 4/6/2021 | Not Ready for Inspection | STUART CHAPMAN |
| Enclosure/Fence | 4/6/2021 | Approved | STUART CHAPMAN |
| PLUMBING-Final | 4/6/2021 | Not Ready for Inspection | STUART CHAPMAN |
| Pool Equipment Noise Test | 5/13/2021 | Approved | ROBERT CHAVEZ |
| ELECTRICAL-Final | 5/19/2021 | Approved | JOSEPH MCGARRY |
| Final | 5/19/2021 | OK to Issue CofO | JOSEPH MCGARRY |
| PLUMBING-Final | 5/19/2021 | Approved | JOSEPH MCGARRY |
| Pool/Spa Cover | 5/19/2021 | Approved | JOSEPH MCGARRY |
| Pre-Gunite | 5/19/2021 | Approved | JOSEPH MCGARRY |
| SGSOV-Seismic Gas S/O Valve | 5/19/2021 | SGSOV Approved | JOSEPH MCGARRY |