22147 W DEL VALLE ST 91364
Certificate Information: 22147 W DEL VALLE ST 91364
- Application / Permit
- 20047-20000-02166
- Plan Check / Job No.
- B20VN15670
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 17' X 30' POOL PER STANDARD PLAN #268
- Permit Issued
- Issued on 2/3/2021
- Issuing Office
- Current Status
- CofO Issued on 7/17/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/4/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 1/13/2021 | RAPHAEL ROSAS |
| Corrections Issued | 1/17/2021 | RAPHAEL ROSAS |
| Issued | 2/3/2021 | APPLICANT |
| CofO in Progress | 7/14/2021 | PETER FOLLING |
| Permit Finaled | 7/17/2021 | MICHAEL SMITH |
| CofO Issued | 7/17/2021 | MICHAEL SMITH |
| Permit Finaled | 7/17/2021 | MICHAEL SMITH |
Permit Application Clearance Information
| Construction near power lines | Cleared | 1/20/2021 | WALTER RAMIREZ |
| Grading Pre-Inspection | Cleared | 2/2/2021 | RAPHAEL ROSAS |
Contact Information
| Contractor | Noga Pool And Spa Inc; Lic. No.: 946647-C53 | 5739 KANAN ROAD #639 AGOURA HILLS, CA 91301 |
| Engineer | Lacher,, Todd Lee; Lic. No.: C67656 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| JOHN HAYES, (818) 774-4302 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Gunite | 2/10/2021 | Approved | PAUL CHOPP |
| Gas Piping or Gas Test | 3/12/2021 | Approved | RONALD COWAN |
| Grounding or Bonding | 3/12/2021 | Approved | RONALD COWAN |
| Enclosure/Fence | 4/19/2021 | Approved | DAVID SANDOVAL |
| Equipment Noise Level | 6/14/2021 | Approved | FELIPE PENICHE |
| Excavation/Setback/Form/Re-Bar | 6/14/2021 | Approved | PETER FOLLING |
| Final | 6/14/2021 | Corrections Issued | PETER FOLLING |
| SGSOV-Seismic Gas S/O Valve | 6/14/2021 | SGSOV Not Ready | PETER FOLLING |
| Final | 6/25/2021 | No Access for Inspection | PETER FOLLING |
| SGSOV-Seismic Gas S/O Valve | 6/25/2021 | SGSOV Not Ready | PETER FOLLING |
| Final | 7/2/2021 | Not Ready for Inspection | PETER FOLLING |
| SGSOV-Seismic Gas S/O Valve | 7/2/2021 | SGSOV Approved | PETER FOLLING |
| Final | 7/7/2021 | OK to Issue CofO | PETER FOLLING |