8304 N GUSTAV LANE 91304
Certificate Information: 8304 N GUSTAV LANE 91304
- Application / Permit
- 20047-20000-02091
- Plan Check / Job No.
- B20VN15208
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 17' X 32' POOL AND 6' X 6' SPA PER STANDARD PLAN #268
- Permit Issued
- Issued on 1/10/2021
- Issuing Office
- Current Status
- CofO Issued on 6/8/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/22/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 11/30/2020 | ROSENDO MEDINA |
| Corrections Issued | 12/1/2020 | ROSENDO MEDINA |
| Issued | 1/10/2021 | APPLICANT |
| CofO in Progress | 4/27/2022 | CHRIS CHRISTENSEN |
| Permit Finaled | 6/8/2022 | JOHN JANSON |
| CofO Issued | 6/8/2022 | JOHN JANSON |
| Permit Finaled | 6/8/2022 | JOHN JANSON |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 12/2/2020 | ROSENDO MEDINA |
| ZA Case | Cleared | 12/21/2020 | STEVEN WECHSLER |
Contact Information
| Contractor | Aqua Escapes Inc; Lic. No.: 1029678-C53 | 8808 DEMPSEY AVE NORTH HILLS, CA 91343 |
| Engineer | Biedenbach,, Christopher James; Lic. No.: C74003 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| JEFFREY HARTLINE, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRIS CHRISTENSEN, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 1/22/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| Pool Piping | 2/5/2021 | Approved | DAVID STEPANYAN |
| Pre-Gunite | 2/5/2021 | Approved | DAVID STEPANYAN |
| Grounding or Bonding | 3/2/2021 | Corrections Issued | DAVID STEPANYAN |
| Grounding or Bonding | 3/19/2021 | Approved | DAVID STEPANYAN |
| Enclosure/Fence | 3/31/2021 | Corrections Issued | DAVID STEPANYAN |
| Enclosure/Fence | 4/7/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| Enclosure/Fence | 4/28/2021 | Approved | DAVID STEPANYAN |
| Equipment Noise Level | 9/20/2021 | Approved | FELIPE PENICHE |
| Enclosure/Fence | 9/24/2021 | Corrections Issued | DAVID STEPANYAN |
| Final | 9/24/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| SGSOV-Seismic Gas S/O Valve | 9/24/2021 | SGSOV Not Required | DAVID STEPANYAN |
| Enclosure/Fence | 3/21/2022 | Not Ready for Inspection | STEVEN BACK |
| Excavation/Setback/Form/Re-Bar | 3/21/2022 | Approved | STEVEN BACK |
| Final | 3/21/2022 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Final | 4/26/2022 | Approved | CHRIS CHRISTENSEN |
| Final | 4/26/2022 | OK to Issue CofO | CHRIS CHRISTENSEN |