244 N LADERA DR 90210
Certificate Information: 244 N LADERA DR 90210
- Application / Permit
- 20047-20000-01793
- Plan Check / Job No.
- B20VN13438
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 69'-6" X 27'-0" SWIMMING POOL AND 8'-9" X 10'-0" SPA WITHIN PER STANDARD PLAN #268 AND ENGINEER DETAIL
- Permit Issued
- Issued on 2/10/2021
- Issuing Office
- Current Status
- CofO Issued on 10/14/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/14/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 10/27/2020 | JEROME MAGAT PALMA |
| Corrections Issued | 10/27/2020 | JEROME MAGAT PALMA |
| Applicant returned to address corrections | 11/25/2020 | JEROME MAGAT PALMA |
| Applicant returned to address corrections | 12/11/2020 | JEROME MAGAT PALMA |
| Plan Check Approved | 2/10/2021 | JEROME MAGAT PALMA |
| Issued | 2/10/2021 | APPLICANT |
| CofO in Progress | 9/27/2022 | CHRISTOPHER WILSON |
| CofO in Progress | 9/27/2022 | CHRISTOPHER WILSON |
| Permit Finaled | 10/14/2022 | DANIEL ORRANTE |
| CofO Issued | 10/14/2022 | DANIEL ORRANTE |
| Permit Finaled | 10/14/2022 | DANIEL ORRANTE |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 11/25/2020 | JEROME MAGAT PALMA |
| ZA Case | Cleared | 2/4/2021 | MIGUEL GAMBOA |
Contact Information
| Contractor | Coastal Aquatic Creations; Lic. No.: 697943-C53 | 149 SOUTH BARRINGTON AVE #158 LOS ANGELES, CA 90049 |
| Engineer | Lacher,, Todd Lee; Lic. No.: C67656 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| RYAN SALAZAR, (310) 914-3862 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 4/9/2021 | Not Ready for Inspection | GERMAN RODRIGUEZ MENDOZA |
| Gas Piping or Gas Test | 4/9/2021 | Not Ready for Inspection | GERMAN RODRIGUEZ MENDOZA |
| Pool Piping | 4/9/2021 | Partial Approval | GERMAN RODRIGUEZ MENDOZA |
| Pre-Gunite | 4/9/2021 | Corrections Issued | GERMAN RODRIGUEZ MENDOZA |
| Rough-Electrical | 4/9/2021 | Partial Approval | GERMAN RODRIGUEZ MENDOZA |
| Rough-Plumbing | 4/9/2021 | Not Ready for Inspection | GERMAN RODRIGUEZ MENDOZA |
| Excavation/Setback/Form/Re-Bar | 4/16/2021 | Approved | CHRISTOPHER WILSON |
| Gas Piping or Gas Test | 4/16/2021 | Not Ready for Inspection | CHRISTOPHER WILSON |
| Grounding or Bonding | 4/16/2021 | Partial Approval | CHRISTOPHER WILSON |
| Pool Piping | 4/16/2021 | Approved | CHRISTOPHER WILSON |
| Pre-Gunite | 4/16/2021 | Approved | CHRISTOPHER WILSON |
| Rough-Electrical | 4/16/2021 | Partial Approval | CHRISTOPHER WILSON |
| Deputy Shotcrete | 4/28/2021 | Conditional Approval | CHRISTOPHER WILSON |
| Deck | 9/13/2021 | Partial Approval | MATT KELLERMAN |
| Enclosure/Fence | 6/7/2022 | Not Ready for Inspection | CHRISTOPHER WILSON |
| Pre-Inspection | 6/7/2022 | Partial Approval | CHRISTOPHER WILSON |
| Enclosure/Fence | 7/13/2022 | Corrections Issued | CHRISTOPHER WILSON |
| Enclosure/Fence | 7/18/2022 | Approved | CHRISTOPHER WILSON |
| Final | 8/26/2022 | Corrections Issued | CHRISTOPHER WILSON |
| SGSOV-Seismic Gas S/O Valve | 8/26/2022 | SGSOV Approved | CHRISTOPHER WILSON |
| Final | 9/9/2022 | Not Ready for Inspection | CHRISTOPHER WILSON |
| Final | 9/26/2022 | OK to Issue CofO | CHRISTOPHER WILSON |