7337 W PACIFIC VIEW DR 90068
Certificate Information: 7337 W PACIFIC VIEW DR 90068
- Application / Permit
- 20047-10000-01721
- Plan Check / Job No.
- B20LA18343
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- CONSTRUCTION OF SWIMMING POOL AND SPA ON GRADE BEAMS + PILES PER ENGINEERING DESIGN
- Permit Issued
- Issued on 4/21/2021
- Issuing Office
- Current Status
- CofO Issued on 3/1/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/6/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 10/29/2020 | CARLOS MONTES |
| Corrections Issued | 11/6/2020 | CARLOS MONTES |
| Quality Review Completed | 11/23/2020 | WING SUEN |
| Applicant returned to address corrections | 4/5/2021 | CARLOS MONTES |
| Plan Check Approved | 4/7/2021 | CARLOS MONTES |
| Issued | 4/21/2021 | APPLICANT |
| Building Plans Picked Up | 4/23/2021 | APPLICANT |
| CofO in Progress | 8/29/2022 | BRIAN SULLIVAN |
| Permit Finaled | 3/1/2023 | DANIEL ORRANTE |
| CofO Issued | 3/1/2023 | DANIEL ORRANTE |
| Permit Finaled | 3/1/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Miscellaneous | Cleared | 1/29/2021 | GABRIEL ROBLES |
| Eng Process Fee Ord 176,300 | Cleared | 2/1/2021 | GABRIEL ROBLES |
| Grading Pre-Inspection | Cleared | 2/5/2021 | CARLOS MONTES |
| Specific Plan | Cleared | 2/22/2021 | OLGA AYALA |
Contact Information
| Contractor | Design Management And Construction Services; Lic. No.: 856999-B | 26007 HUNTINGTON LANE STE 7 VALENCIA, CA 91355 |
| Engineer | Hollingsworth,, Robert Alan; Lic. No.: GE2022 | 31129 VIA COLINAS SUITE 707 WESTLAKE VILLAGE, CA 91362 |
| Engineer | Roberts,, Jeffrey Allan; Lic. No.: C56881 | 8325 FOOTHILL BLVD. STE A SUNLAND, CA 91040 |
| Geologist | Hollingsworth,, Robert Alan; Lic. No.: EG1265 | 31129 VIA COLINAS SUITE 707 WESTLAKE VILLAGE, CA 91362 |
Inspector Information
| ROY SPAULDING, (213) 202-3461 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Grading | 7/22/2021 | Conditional Approval | BRIAN SULLIVAN |
| Piling/Pier/Caisson | 8/3/2021 | Partial Approval | BRIAN SULLIVAN |
| Piling/Pier/Caisson | 8/16/2021 | Approved | BRIAN SULLIVAN |
| Pre-Gunite | 10/14/2021 | Approved | CRAIG DAVIS |
| Deputy Shotcrete | 10/15/2021 | Conditional Approval | COREY HUPP |
| Gas Piping or Gas Test | 11/10/2021 | Approved | BRIAN SULLIVAN |
| Pool Piping | 11/10/2021 | Approved | BRIAN SULLIVAN |
| Deck | 3/1/2022 | Approved | BRIAN SULLIVAN |
| Enclosure/Fence | 5/6/2022 | Not Ready for Inspection | BRIAN SULLIVAN |
| Enclosure/Fence | 5/9/2022 | Approved | BRIAN SULLIVAN |
| Equipment Noise Level | 8/24/2022 | Approved | ROBERT CHAVEZ |
| Excavation/Setback/Form/Re-Bar | 8/25/2022 | Approved | BRIAN SULLIVAN |
| Final | 8/25/2022 | OK to Issue CofO | BRIAN SULLIVAN |
| SGSOV-Seismic Gas S/O Valve | 8/25/2022 | SGSOV Approved | BRIAN SULLIVAN |