721 N DILLON ST 90026
Certificate Information: 721 N DILLON ST 90026
- Application / Permit
- 20047-10000-01609
- Plan Check / Job No.
- B20LA17429
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW POOL 14'x26' FROM 3'6" DEEP TO 5' DEEP NEW SPA 8'x8' 3'6" DEEP
- Permit Issued
- Issued on 11/9/2020
- Issuing Office
- Current Status
- CofO Issued on 7/3/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/25/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 9/30/2020 | AMIR DANAI |
| Corrections Issued | 9/30/2020 | AMIR DANAI |
| Plan Check Approved | 11/2/2020 | GEORGE ALVAREZ |
| Issued | 11/9/2020 | APPLICANT |
| Building Plans Picked Up | 11/12/2020 | APPLICANT |
| CofO in Progress | 6/23/2021 | ROBERT VORHIS |
| Permit Finaled | 7/3/2021 | DEROLD HAUFF |
| CofO Issued | 7/3/2021 | DEROLD HAUFF |
| Permit Finaled | 7/3/2021 | DEROLD HAUFF |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Intex Design And Construction Inc; Lic. No.: 981718-B | 15021 VENTURA BLVD STE 520 SHERMAN OAKS, CA 91403 |
| Engineer | Biedenbach,, Christopher James; Lic. No.: C74003 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
| Engineer | Lacher,, Todd Lee; Lic. No.: C67656 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| FREDDIE RIVERA, (213) 202-3437 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Gas Piping or Gas Test | 3/1/2021 | Approved | ROBERT VORHIS |
| Pre-Gunite | 3/1/2021 | Approved | ROBERT VORHIS |
| Rough-Electrical | 3/1/2021 | Partial Approval | ROBERT VORHIS |
| Rough-Plumbing | 3/1/2021 | Approved | ROBERT VORHIS |
| Deputy Shotcrete | 3/17/2021 | Conditional Approval | ROBERT VORHIS |
| Deck | 4/7/2021 | Approved | ROBERT VORHIS |
| Grading Pre-Inspection | 4/7/2021 | Not Ready for Inspection | ROBERT VORHIS |
| Grounding or Bonding | 4/7/2021 | Approved | ROBERT VORHIS |
| Enclosure/Fence | 5/7/2021 | Approved | ROBERT VORHIS |
| Pool Equipment Noise Test | 6/1/2021 | Approved | ROBERT CHAVEZ |
| Excavation/Setback/Form/Re-Bar | 6/3/2021 | Approved | ROBERT VORHIS |
| Final | 6/3/2021 | Corrections Issued | ROBERT VORHIS |
| SGSOV-Seismic Gas S/O Valve | 6/3/2021 | SGSOV Approved | ROBERT VORHIS |
| Final | 6/15/2021 | Partial Inspection | ROBERT VORHIS |
| Enclosure/Fence | 6/21/2021 | Approved | ROBERT VORHIS |
| Final | 6/21/2021 | Conditional Approval | ROBERT VORHIS |