18145 W KAREN DR 91356

Certificate Information: 18145 W KAREN DR 91356

Application / Permit
20030-20000-02172
Plan Check / Job No.
B20VN06092
Group
Building
Type
Grading
Sub-Type
1 or 2 Family Dwelling
Primary Use
(70) Grading - Hillside
Work Description
Grading Permit for Excavation and Backfill of Site Retaining Wall & Basement Retaining Wall, Site Prep. including Slope Trimming per Soil Report approved by the LADB Grading Div. for the proposed Single Family Dwelling with attached Garage.
Permit Issued
Issued on 4/19/2021
Issuing Office
Valley
Current Status
Permit Finaled on 6/13/2024

Permit Application Status History

Submitted 4/28/2020 APPLICANT
Assigned to Plan Check Engineer 5/21/2020 OMID HEDAYAT
Plans on Hold 6/1/2020 OMID HEDAYAT
Green Plans Picked Up 6/23/2020 APPLICANT
Hold Released 6/29/2020 OMID HEDAYAT
Corrections Issued 7/1/2020 OMID HEDAYAT
Quality Review Completed 7/8/2020 STEVEN KIM
Building Plans Picked Up 7/9/2020 APPLICANT
Applicant returned to address corrections 9/17/2020 OMID HEDAYAT
Applicant returned to address corrections 2/26/2021 OMID HEDAYAT
Applicant returned to address corrections 3/10/2021 OMID HEDAYAT
Applicant returned to address corrections 3/31/2021 OMID HEDAYAT
Plan Check Approved 3/31/2021 OMID HEDAYAT
Issued 4/19/2021 APPLICANT
Permit Finaled 6/12/2024 ALEXANDER HELFER

Permit Application Clearance Information

Hold Cleared 6/15/2020 JEREMY CORONEL
GPI Written Notices Cleared 3/17/2021 OMID HEDAYAT
Grading Pre-Inspection Cleared 3/17/2021 OMID HEDAYAT

Contact Information

Contractor Owner-Builder       ,

Inspector Information

MANUEL TEJADA, (818) 374-4339 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Initial Grading 5/4/2021 Approved ALEXANDER ANDREWS
Deputy Grading 6/1/2021 Approved ALEXANDER ANDREWS
Rough 6/2/2021 Not Ready for Inspection ALEXANDER ANDREWS
Bottom/Toe 6/3/2021 Partial Approval ALEXANDER ANDREWS
Rough 6/7/2021 Partial Approval ALEXANDER ANDREWS
Sub-Drain 6/30/2021 Approved ALEXANDER HELFER
Sub-Drain 8/11/2021 Approved ALEXANDER ANDREWS
Special/Order Compliance 8/16/2021 Partial Inspection ALEXANDER ANDREWS
Special/Order Compliance 8/18/2021 Partial Approval ALEXANDER ANDREWS
Special/Order Compliance 9/2/2021 Partial Inspection ALEXANDER ANDREWS
Special/Order Compliance 9/7/2021 Partial Inspection ALEXANDER ANDREWS
Special/Order Compliance 9/16/2021 No Access for Inspection ALEXANDER ANDREWS
Special/Order Compliance 9/28/2021 Partial Inspection TIMOTHY POWELL
Special/Order Compliance 10/1/2021 Partial Inspection TIMOTHY POWELL
Special/Order Compliance 10/15/2021 Partial Approval ALEXANDER ANDREWS
Approved Compaction Report 4/2/2024 Approved CHARLES POWELL
Bottom/Toe 6/12/2024 Approved ALEXANDER HELFER
Final 6/12/2024 Permit Finaled ALEXANDER HELFER
Rough 6/12/2024 Approved ALEXANDER HELFER