128-130 S EDGEMONT ST 90004
Certificate Information: 128-130 S EDGEMONT ST 90004
- Application / Permit
- 20016-40000-07348
- Plan Check / Job No.
- X20SP01187
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over existing solid sheathing 18 Squares. Class A roof covering is required within Very High Fire Hazard Severity Zone (VHFHSZ). For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roof Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 149(b). ( 2 ) Kitchen ( 4 ) bathroom remodel for residential buildings (no structural changes) combined with mech/elec/plumb). ( 2 ) Window change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 152(b) of Title 24. Replace drywall (no new walls added) for single family dwellings and duplexes only. Add sill plate anchor bolts and plywood to cripple walls (if existing) per LA City Standard Plan #1; no foundation replacement (Earthquake hazard reduction per Chapter 92 of the Los Angeles Building Code). (Houses, residential buildings up to 3 stories and up to 4 units). Replacement of damaged framing members (less than 10% of replacement cost of building) for houses and duplexes (not including decks).
- Permit Issued
- Issued on 3/13/2020
- Issuing Office
- San Pedro
- Current Status
- Issued on 3/13/2020
Permit Application Status History
| Issued | 3/13/2020 | LADBS |
Permit Application Clearance Information
| Hold | Cleared | 4/2/2020 | JEREMY CORONEL |
Contact Information
| Contractor | Bay Cities Construction; Lic. No.: 842614-B | 23890 HAWTHORNE BLVD TORRANCE, CA 90505 |
Inspector Information
| WILLIAM SIERRA, (213) 202-3122 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| BUILDING-Rough-Frame | 4/7/2020 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| Rough-Elec/Plmb/HVAC | 4/7/2020 | Corrections Issued | KATHRYN BUTTERWORTH |
| Rough-Elec/Plmb/HVAC | 4/14/2020 | Approved | KATHRYN BUTTERWORTH |
| Insulation | 4/24/2020 | Approved | KATHRYN BUTTERWORTH |
| Interior/Exterior Lathing | 5/11/2020 | Partial Approval | THOMAS LOGRASSO |
| Shower Pan | 5/11/2020 | Approved | THOMAS LOGRASSO |
| Drywall Nailing | 6/19/2020 | Approved | THOMAS LOGRASSO |