6431 W FIREBRAND ST 90045
Certificate Information: 6431 W FIREBRAND ST 90045
- Application / Permit
- 20016-30000-29079
- Plan Check / Job No.
- B20WL04908
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Interior structural remodel of (e) SFD. Scope of work to include kitchen remodel and new bedroom and bathroom.
- Permit Issued
- Issued on 6/8/2021
- Issuing Office
- Current Status
- Permit Finaled on 6/10/2022
Permit Application Status History
| Submitted | 11/10/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 11/17/2020 | JASON JANGADA |
| Corrections Issued | 11/19/2020 | JASON JANGADA |
| Applicant returned to address corrections | 1/13/2021 | RICHARD GARCIA |
| Plan Check Approved | 3/10/2021 | JASON JANGADA |
| Issued | 6/8/2021 | APPLICANT |
| Building Plans Picked Up | 6/11/2021 | APPLICANT |
| Permit Finaled | 6/9/2022 | RICHARD STEINBACH |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 2/24/2021 | PATRICK MISCHLICH |
| Eng Process Fee Ord 176,300 | Cleared | 2/25/2021 | NIKTA MOUSAVI |
| Sewer availability | Cleared | 2/26/2021 | NIKTA MOUSAVI |
Contact Information
| Contractor | Ludis Inc; Lic. No.: 1061815-B | 3415 S SEPULVEDA BLVD STE 1100 LOS ANGELES, CA 90034 |
| Engineer | Shirley,, Peter Franklin; Lic. No.: C75050 | 4429 DAWES AVE CULVER CITY, CA 90230 |
Inspector Information
| MORRIS JACKSON, (310) 914-3885 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 6/17/2021 | No Access for Inspection | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 6/18/2021 | Not Ready for Inspection | ENRIQUE MIRELES |
| Pre-Inspection | 6/18/2021 | Approved | ENRIQUE MIRELES |
| Footing/Foundation/Slab | 6/22/2021 | Approved | DONALD GALLAGHER |
| Footing/Foundation/Slab | 7/2/2021 | Approved | DONALD GALLAGHER |
| Wood Frame | 7/2/2021 | Approved | DONALD GALLAGHER |
| Final | 12/28/2021 | Corrections Issued | ENRIQUE MIRELES |
| SGSOV-Seismic Gas S/O Valve | 12/28/2021 | SGSOV Not Ready | ENRIQUE MIRELES |
| Smoke Detectors | 12/28/2021 | Not Ready for Inspection | ENRIQUE MIRELES |
| Final | 6/9/2022 | Permit Finaled | RICHARD STEINBACH |
| SGSOV-Seismic Gas S/O Valve | 6/9/2022 | SGSOV Approved | RICHARD STEINBACH |
| Smoke Detectors | 6/9/2022 | Approved | RICHARD STEINBACH |