21908-21910 W GRESHAM ST 91304
Certificate Information: 21908-21910 W GRESHAM ST 91304
- Application / Permit
- 20016-20000-32051
- Plan Check / Job No.
- B20VN16002
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- CONVERT (E) ATTACHED GARAGE INTO ACCESSORY DWELLING UNIT (471 SQ FT) PER LAMC 12.22 A. 33(c) and (e)
- Permit Issued
- Issued on 4/28/2021
- Issuing Office
- Current Status
- CofO Issued on 12/22/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/21/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 12/30/2020 | JEROME MAGAT PALMA |
| Corrections Issued | 1/3/2021 | JEROME MAGAT PALMA |
| Applicant returned to address corrections | 1/28/2021 | JEROME MAGAT PALMA |
| Plan Check Approved | 4/1/2021 | JEROME MAGAT PALMA |
| Issued | 4/28/2021 | APPLICANT |
| CofO in Progress | 12/21/2021 | TROY SANDERS |
| Permit Finaled | 12/22/2021 | JOHN JANSON |
| CofO Issued | 12/22/2021 | JOHN JANSON |
| Permit Finaled | 12/22/2021 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 3/1/2021 | MARKOS PEREZ-BRAN |
| Eng Process Fee Ord 176,300 | Cleared | 3/1/2021 | MARKOS PEREZ-BRAN |
| Sewer availability | Cleared | 3/1/2021 | MARKOS PEREZ-BRAN |
| Grading Pre-Inspection | Cleared | 4/1/2021 | JEROME MAGAT PALMA |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JEFFREY HARTLINE, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRIS CHRISTENSEN, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 7/19/2021 | Partial Approval | DAVID STEPANYAN |
| Pre-Inspection | 7/19/2021 | Partial Inspection | DAVID STEPANYAN |
| BUILDING-Rough-Frame | 8/9/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| Green Building Rough | 8/9/2021 | Corrections Issued | DAVID STEPANYAN |
| Wood Frame | 8/9/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| PLUMBING-Rough | 9/1/2021 | Approved | PETER FOLLING |
| ELECTRICAL-Rough | 9/7/2021 | Approved | DAVID STEPANYAN |
| BUILDING-Rough-Frame | 9/14/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| Green Building Rough | 9/14/2021 | Corrections Issued | DAVID STEPANYAN |
| HVAC-Rough | 9/14/2021 | Partial Approval | DAVID STEPANYAN |
| Interior/Exterior Lathing | 9/14/2021 | Partial Approval | DAVID STEPANYAN |
| BUILDING-Rough-Frame | 9/20/2021 | Partial Approval | DAVID STEPANYAN |
| Green Building Rough | 9/20/2021 | Approved | DAVID STEPANYAN |
| Insulation | 9/20/2021 | Approved | DAVID STEPANYAN |
| Shower Pan | 9/23/2021 | Approved | DAVID STEPANYAN |
| BUILDING-Rough-Frame | 10/26/2021 | Approved | DAVID STEPANYAN |
| ELECTRICAL-Final | 10/26/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| Final | 11/17/2021 | Corrections Issued | DAVID STEPANYAN |
| Green Building Final | 11/17/2021 | Corrections Issued | DAVID STEPANYAN |
| SGSOV-Seismic Gas S/O Valve | 11/17/2021 | SGSOV Not Ready | DAVID STEPANYAN |
| Smoke Detectors | 11/17/2021 | Not Ready for Inspection | DAVID STEPANYAN |
| Final | 11/29/2021 | Not Ready for Inspection | TROY SANDERS |
| Green Building Final | 11/29/2021 | Approved | TROY SANDERS |
| SGSOV-Seismic Gas S/O Valve | 11/29/2021 | SGSOV Approved | TROY SANDERS |
| Smoke Detectors | 11/29/2021 | Approved | TROY SANDERS |
| Final | 12/21/2021 | OK to Issue CofO | TROY SANDERS |