5052 N BILOXI AVE 91601
Certificate Information: 5052 N BILOXI AVE 91601
- Application / Permit
- 20016-20000-28757
- Plan Check / Job No.
- B20VN14504
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT 15' X 20' (E) DETACHED REC ROOM W/ 3'-6" X 20' PATIO COVER AND CONVERT 15' X 17' (E) DETACHED REC ROOM W/ 3'-6" X 17' PATIO COVER AND ADD 13' X 16' W/ 3'-6" X 13' PATIO COVER TO CONNECT INTO ONE STRUCTURE TO CREATE A (N) DETACHED ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) AND (d). ALL WORK PER ENGINEERING. NFPA 13D FIRE SPRINKLERS THROUGHOUT.
- Permit Issued
- Issued on 12/13/2021
- Issuing Office
- Current Status
- CofO Issued on 2/7/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/16/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 12/30/2020 | RAPHAEL ROSAS |
| Corrections Issued | 1/2/2021 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 6/7/2021 | RAPHAEL ROSAS |
| Building Plans Picked Up | 6/24/2021 | APPLICANT |
| Issued | 12/13/2021 | APPLICANT |
| CofO in Progress | 1/12/2024 | JOHN HAYES |
| Permit Finaled | 2/7/2024 | RUBEN SALAS |
| CofO Issued | 2/7/2024 | RUBEN SALAS |
| Permit Finaled | 2/7/2024 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 1/5/2021 | ADRIAN CASTRO |
| Eng Process Fee Ord 176,300 | Cleared | 1/6/2021 | ADRIAN CASTRO |
| Sewer availability | Cleared | 1/6/2021 | ADRIAN CASTRO |
| Construction near power lines | Cleared | 3/29/2021 | RIDWAN HARDY |
| Low Impact Development | Cleared | 6/7/2021 | AMMAR ELTAWIL |
| Roof/Waste drainage to street | Cleared | 6/7/2021 | ABDULLAH SADOZAI |
Contact Information
| Contractor | All State Construction Inc; Lic. No.: 1056262-B | 509 N FAIRFAX AVE SUITE 209 LOS ANGELES, CA 90036 |
| Engineer | Basso,, Alexandre; Lic. No.: C77670 | 7231 SUMMITROSE ST TUJUNGA, CA 91042 |
Inspector Information
| GAREN HAYRAPETYAN, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
| ROBERTO PALACIOS-LOPEZ, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 12/27/2021 | Approved | JACK KARGODORIAN |
| Excavation/Setback/Form/Re-Bar | 12/27/2021 | Approved | JACK KARGODORIAN |
| BUILDING-Rough-Frame | 1/21/2022 | Approved | MATT KELLERMAN |
| ELECTRICAL-Rough | 1/21/2022 | Approved | MATT KELLERMAN |
| Green Building Rough | 1/21/2022 | Approved | MATT KELLERMAN |
| HVAC-Final | 1/21/2022 | Not Ready for Inspection | MATT KELLERMAN |
| PLUMBING-Rough | 1/21/2022 | Approved | MATT KELLERMAN |
| Insulation | 1/26/2022 | Corrections Issued | MISAEL ESPARZA |
| Insulation | 3/8/2022 | Approved | DAVID MATSON |
| Drywall Nailing | 3/21/2022 | Approved | CALEB MEISTER |
| Verify Sprinkler Sign Off | 3/21/2022 | Approved | CALEB MEISTER |
| Final | 5/16/2022 | Corrections Issued | JACK KARGODORIAN |
| Footing/Foundation/Slab | 5/16/2022 | Approved | JACK KARGODORIAN |
| Green Building Final | 5/16/2022 | Not Ready for Inspection | JACK KARGODORIAN |
| SGSOV-Seismic Gas S/O Valve | 5/16/2022 | SGSOV Not Ready | JACK KARGODORIAN |
| Smoke Detectors | 5/16/2022 | Approved | JACK KARGODORIAN |
| Final | 9/18/2023 | Corrections Issued | JOHN HAYES |
| Green Building Final | 9/18/2023 | Approved | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 9/18/2023 | SGSOV Approved | JOHN HAYES |
| Final | 11/7/2023 | Corrections Issued | JENNIFER RABUCHIN |
| Final | 1/11/2024 | OK to Issue CofO | JOHN HAYES |