2369 N JUPITER DR 90046
Certificate Information: 2369 N JUPITER DR 90046
- Application / Permit
- 20016-20000-17495
- Plan Check / Job No.
- B20VN09536
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- INTERIOR REMODEL TO (E) SFD, ADD 117SF COVERED PATIO/PORCH, OPEN BALCONY AND OPEN ROOF DECK [SEE COMMENTS].
- Permit Issued
- Issued on 12/14/2020
- Issuing Office
- Current Status
- CofO Issued on 4/1/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/22/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/30/2020 | DAWN MC NULTY |
| Corrections Issued | 8/10/2020 | DAWN MC NULTY |
| Quality Review Completed | 8/13/2020 | CHON CHIO KUO |
| Building Plans Picked Up | 8/18/2020 | APPLICANT |
| Applicant returned to address corrections | 10/23/2020 | DAWN MC NULTY |
| Applicant returned to address corrections | 12/10/2020 | DAWN MC NULTY |
| Plan Check Approved | 12/14/2020 | DAWN MC NULTY |
| Issued | 12/14/2020 | APPLICANT |
| CofO in Progress | 12/9/2022 | RAUL BARAJAS |
| Permit Finaled | 4/1/2023 | DANIEL ORRANTE |
| CofO Issued | 4/1/2023 | DANIEL ORRANTE |
| Permit Finaled | 4/1/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 8/28/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 8/28/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 8/28/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 8/28/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 8/28/2020 | ELAINE LEI |
| Eng Process Fee Ord 176,300 | Cleared | 8/28/2020 | ELAINE LEI |
| Sewer availability | Cleared | 8/28/2020 | ELAINE LEI |
| Distance to fire station | Cleared | 9/21/2020 | JOHN CONNEALLY |
| Grading Pre-Inspection | Cleared | 10/26/2020 | DAWN MC NULTY |
| Low Impact Development | Cleared | 10/27/2020 | MITESH PATEL |
| Roof/Waste drainage to street | Cleared | 10/27/2020 | ELAINE LEI |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Farag,, Amgad N; Lic. No.: C74076 | 27050 MAPLE TREE CT VALENCIA, CA 91381 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Special/Order Compliance | 2/18/2021 | Corrections Issued | RAUL BARAJAS |
| Special/Order Compliance | 3/25/2021 | Corrections Issued | RAUL BARAJAS |
| Deputy Drilled-In Anchors | 4/7/2021 | Conditional Approval | RAUL BARAJAS |
| BUILDING-Rough-Frame | 4/15/2021 | Not Ready for Inspection | RAUL BARAJAS |
| ELECTRICAL-Rough | 4/15/2021 | Not Ready for Inspection | RAUL BARAJAS |
| Footing/Foundation/Slab | 4/15/2021 | Not Ready for Inspection | RAUL BARAJAS |
| Green Building Rough | 4/15/2021 | Not Ready for Inspection | RAUL BARAJAS |
| Excavation/Setback/Form/Re-Bar | 4/20/2021 | Approved | RAUL BARAJAS |
| Footing/Foundation/Slab | 5/4/2021 | Corrections Issued | RAUL BARAJAS |
| Masonry Wall/Backfill | 5/4/2021 | Approved | RAUL BARAJAS |
| ELECTRICAL-Rough | 5/10/2021 | Partial Approval | RAUL BARAJAS |
| HVAC-Rough | 5/10/2021 | Partial Approval | RAUL BARAJAS |
| Masonry Wall/Backfill | 5/19/2021 | Partial Approval | BRIAN SULLIVAN |
| BUILDING-Rough-Frame | 6/4/2021 | Not Ready for Inspection | BRIAN SULLIVAN |
| Green Building Rough | 6/4/2021 | Not Ready for Inspection | BRIAN SULLIVAN |
| PLUMBING-Rough | 6/9/2021 | Approved | RAUL BARAJAS |
| BUILDING-Rough-Frame | 9/15/2021 | Not Ready for Inspection | RAUL BARAJAS |
| Green Building Rough | 9/15/2021 | Approved | RAUL BARAJAS |
| Wood Frame | 9/15/2021 | Not Ready for Inspection | RAUL BARAJAS |
| Deputy Wood Construction | 9/17/2021 | Conditional Approval | RAUL BARAJAS |
| ELECTRICAL-Rough | 9/28/2021 | Approved | RAUL BARAJAS |
| HVAC-Rough | 9/28/2021 | Approved | RAUL BARAJAS |
| Insulation | 10/4/2021 | Approved | RAUL BARAJAS |
| Shower Pan | 10/8/2021 | Approved | RAUL BARAJAS |
| Drywall Nailing | 11/1/2021 | No Access for Inspection | RAUL BARAJAS |
| Drywall Nailing | 11/4/2021 | Approved | RAUL BARAJAS |
| Interior/Exterior Lathing | 11/29/2021 | Partial Approval | AMY COLIN |
| Interior/Exterior Lathing | 12/6/2021 | Approved | RAUL BARAJAS |
| ELECTRICAL-Final | 7/8/2022 | Corrections Issued | JEFFREY MEAD |
| Smoke Detectors | 7/8/2022 | Approved | JEFFREY MEAD |
| ELECTRICAL-Final | 8/1/2022 | Approved | RAUL BARAJAS |
| HVAC-Final | 9/7/2022 | Conditional Approval | RAUL BARAJAS |
| PLUMBING-Final | 9/7/2022 | Approved | RAUL BARAJAS |
| BUILDING-Rough-Frame | 12/5/2022 | Not Ready for Inspection | BRIAN SULLIVAN |
| Final | 12/5/2022 | Not Ready for Inspection | BRIAN SULLIVAN |
| Footing/Foundation/Slab | 12/5/2022 | Not Ready for Inspection | BRIAN SULLIVAN |
| Green Building Final | 12/5/2022 | Not Ready for Inspection | BRIAN SULLIVAN |
| SGSOV-Seismic Gas S/O Valve | 12/5/2022 | SGSOV Not Ready | BRIAN SULLIVAN |
| BUILDING-Rough-Frame | 12/9/2022 | Approved | RAUL BARAJAS |
| Final | 12/9/2022 | OK to Issue CofO | RAUL BARAJAS |
| Footing/Foundation/Slab | 12/9/2022 | Approved | RAUL BARAJAS |
| Green Building Final | 12/9/2022 | Approved | RAUL BARAJAS |
| SGSOV-Seismic Gas S/O Valve | 12/9/2022 | SGSOV Approved | RAUL BARAJAS |