10769 W ADDISON ST 91601

Certificate Information: 10769 W ADDISON ST 91601

Application / Permit
20016-20000-16562
Plan Check / Job No.
X20VN08284
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Kitchen (3)/bathroom (3) remodel for residential buildings (no structural changes). Window (21) and door (3) change-out (same size & type) for residential buildings. Dual glazing, labeled and certified by National Fenestration Rating Council (NFRC), is required for doors and windows replaced in all residential buildings, three stories or less, per Section 150.2(b)1B of Title 24. Re-roof with Class A or B material weighing less than 6 pounds per sq. ft. over new solid sheathing (30) squares. For residential roof replacement > 50% of the total roof area, apply Cool Roof Product labeled and certified by Cool Roofing Rating Council (CRRC). Cool Roof may be required for non-residential buildings per Title 24, Part 6, Section 141.0(b)2B. Fiber Cement siding over solid sheathing with an approved water resistive barrier per valid ICC Evaluation Report #ESR 2290 on exterior walls at 5 feet or more from property lines for residential buildings. (Applicant to provide a copy of the report to inspector).
Permit Issued
Issued on 8/17/2020
Issuing Office
Current Status
Permit Finaled on 4/28/2021

Permit Application Status History

No Progress 7/13/2020 BLANCA MORALES
Issued 8/17/2020 APPLICANT
Permit Finaled 4/28/2021 HAMID PISHEHVAR

Permit Application Clearance Information

Historic Resource Verification Cleared 7/16/2020 MICAELA TORRES-GIL
Redevelopment Project Area Cleared 8/11/2020 MICAELA TORRES-GIL

Contact Information

Contractor Nest Interiors Inc; Lic. No.: 1033348-B 530 S LAKE AVE SUITE 271N      PASADENA, CA 91101

Inspector Information

JEFFREY FULTON, (818) 374-1132 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Floor/Roof Diaphrgm/Shear Wall 9/16/2020 Approved ROBERT DAVIS
Interior/Exterior Lathing 10/20/2020 Partial Approval ROBERT DAVIS
Wood Frame 10/20/2020 Approved ROBERT DAVIS
Drywall Nailing 10/30/2020 Approved ROBERT DAVIS
Insulation 10/30/2020 Approved ROBERT DAVIS
Interior/Exterior Lathing 11/4/2020 Approved ROBERT DAVIS
SGSOV-Seismic Gas S/O Valve 3/30/2021 SGSOV Not Ready ROBERT DAVIS
Final 4/28/2021 Permit Finaled HAMID PISHEHVAR
SGSOV-Seismic Gas S/O Valve 4/28/2021 SGSOV Approved HAMID PISHEHVAR
Smoke Detectors 4/28/2021 Approved HAMID PISHEHVAR