13359 W CORNELIUS ST 91331
Certificate Information: 13359 W CORNELIUS ST 91331
- Application / Permit
- 20016-20000-01169
- Plan Check / Job No.
- B20VN00616
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- Convert the detached garage into an Accessory Dwelling Unit
- Permit Issued
- Issued on 1/15/2020
- Issuing Office
- Valley
- Current Status
- CofO Issued on 9/29/2020
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/15/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 1/15/2020 | ANGELICA DAVE |
| Corrections Issued | 1/15/2020 | ANGELICA DAVE |
| Plan Check Approved | 1/15/2020 | ARTIN ZARUKIAN |
| Issued | 1/15/2020 | LADBS |
| CofO in Progress | 9/25/2020 | MICHAEL TEMPLE |
| Permit Finaled | 9/29/2020 | MICHAEL SMITH |
| CofO Issued | 9/29/2020 | MICHAEL SMITH |
| Permit Finaled | 9/29/2020 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 1/15/2020 | MARKOS PEREZ-BRAN |
| Eng Process Fee Ord 176,300 | Cleared | 1/15/2020 | MARKOS PEREZ-BRAN |
| Sewer availability | Cleared | 1/15/2020 | MARKOS PEREZ-BRAN |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| MICHEL ABAJAN, (818) 374-9932 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 2/7/2020 | Partial Approval | MISAEL ESPARZA |
| PLUMBING-Rough | 2/7/2020 | Partial Approval | MISAEL ESPARZA |
| BUILDING-Rough-Frame | 2/28/2020 | Not Ready for Inspection | MICHEL ABAJAN |
| Green Building Rough | 2/28/2020 | Not Ready for Inspection | MICHEL ABAJAN |
| MERV13>=Rough | 2/28/2020 | Not Ready for Inspection | MICHEL ABAJAN |
| Sewer | 2/28/2020 | Approved | MICHEL ABAJAN |
| BUILDING-Rough-Frame | 3/31/2020 | Approved | MICHEL ABAJAN |
| ELECTRICAL-Rough | 3/31/2020 | Approved | MICHEL ABAJAN |
| Green Building Rough | 3/31/2020 | Approved | MICHEL ABAJAN |
| MERV13>=Rough | 3/31/2020 | Approved | MICHEL ABAJAN |
| PLUMBING-Rough | 3/31/2020 | Approved | MICHEL ABAJAN |
| Insulation | 4/7/2020 | Approved | MICHEL ABAJAN |
| Drywall Nailing | 4/14/2020 | Approved | MICHEL ABAJAN |
| Interior/Exterior Lathing | 4/16/2020 | Approved | MICHEL ABAJAN |
| ELECTRICAL-Final | 6/10/2020 | Approved | MICHEL ABAJAN |
| Final | 6/10/2020 | Not Ready for Inspection | MICHEL ABAJAN |
| Green Building Final | 6/10/2020 | Approved | MICHEL ABAJAN |
| HVAC-Final | 6/10/2020 | Approved | MICHEL ABAJAN |
| MERV13>=Final | 6/10/2020 | Approved | MICHEL ABAJAN |
| PLUMBING-Final | 6/10/2020 | Approved | MICHEL ABAJAN |
| SGSOV-Seismic Gas S/O Valve | 6/10/2020 | SGSOV Approved | MICHEL ABAJAN |
| Smoke Detectors | 6/10/2020 | Approved | MICHEL ABAJAN |
| Final | 8/19/2020 | Corrections Issued | MICHEL ABAJAN |
| Final | 8/25/2020 | OK to Issue CofO | JENNIFER RABUCHIN |