106 N HIGHLAND AVE 90036
Certificate Information: 106 N HIGHLAND AVE 90036
- Application / Permit
- 20016-10000-31632
- Plan Check / Job No.
- B20LA22689
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- **ePlan** (N) attached patio cover per Eng.
- Permit Issued
- Issued on 3/18/2021
- Issuing Office
- Current Status
- CofO Issued on 7/5/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/8/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 1/14/2021 | CARLOS MONTES |
| Corrections Issued | 1/20/2021 | CARLOS MONTES |
| Quality Review Completed | 2/4/2021 | TU HUA |
| Plan Check Approved | 2/23/2021 | CARLOS MONTES |
| Issued | 3/18/2021 | APPLICANT |
| CofO in Progress | 6/16/2025 | RONNIE MINDANAO |
| CofO in Progress | 6/16/2025 | RONNIE MINDANAO |
| CofO in Progress | 6/17/2025 | RONNIE MINDANAO |
| Permit Finaled | 7/5/2025 | DEROLD HAUFF |
| Permit Finaled | 7/5/2025 | DEROLD HAUFF |
| CofO Issued | 7/5/2025 | DEROLD HAUFF |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 2/3/2021 | ELENA LOPEZ |
| Roof/Waste drainage to street | Cleared | 2/3/2021 | ELENA LOPEZ |
| CPC | Cleared | 2/5/2021 | RICHARD REASER |
| HPOZ | Cleared | 2/12/2021 | SUKI GERSHENHORN |
Contact Information
| Contractor | Excel Construction L A Inc; Lic. No.: 998499-B | , |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 5330 ZELZAH AVE UNIT 7 ENCINO, CA 91316 |
Inspector Information
| RONNIE MINDANAO, (213) 202-3252 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 4/23/2021 | Approved | CHRIS CHRISTENSEN |
| Footing/Foundation/Slab | 4/26/2021 | Not Ready for Inspection | ROBERT VORHIS |
| METHANE-Barrier | 4/26/2021 | Approved | ROBERT VORHIS |
| METHANE-Subgrade | 4/26/2021 | Approved | ROBERT VORHIS |
| Wood Frame | 5/7/2021 | Partial Approval | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 5/24/2021 | Approved | JOSEPH MCGARRY |
| Wood Frame | 5/24/2021 | Partial Approval | JOSEPH MCGARRY |
| Floor/Roof Diaphrgm/Shear Wall | 5/28/2021 | Approved | JOSEPH MCGARRY |
| Wood Frame | 5/28/2021 | Not Ready for Inspection | JOSEPH MCGARRY |
| Interior/Exterior Lathing | 6/4/2021 | Approved | WILLIAM WREN |
| BUILDING-Rough-Frame | 6/11/2021 | Not Ready for Inspection | JOSEPH MCGARRY |
| Final | 6/11/2021 | Corrections Issued | JOSEPH MCGARRY |
| Footing/Foundation/Slab | 6/11/2021 | Approved | JOSEPH MCGARRY |
| METHANE-Final | 6/11/2021 | Approved | JOSEPH MCGARRY |
| METHANE-Rough | 6/11/2021 | Approved | JOSEPH MCGARRY |
| SGSOV-Seismic Gas S/O Valve | 6/11/2021 | SGSOV Not Ready | JOSEPH MCGARRY |
| Smoke Detectors | 6/11/2021 | Not Ready for Inspection | JOSEPH MCGARRY |
| BUILDING-Rough-Frame | 7/28/2021 | Approved | ARTHUR SARGSYAN |
| Final | 7/28/2021 | Not Ready for Inspection | ARTHUR SARGSYAN |
| SGSOV-Seismic Gas S/O Valve | 7/28/2021 | SGSOV Approved | ARTHUR SARGSYAN |
| Smoke Detectors | 7/28/2021 | Approved | ARTHUR SARGSYAN |
| Final | 5/15/2025 | Conditional Approval | RONNIE MINDANAO |
| Final | 6/16/2025 | OK to Issue CofO | RONNIE MINDANAO |