3750 S VINTON AVE 1-20 90034
Certificate Information: 3750 S VINTON AVE 1-20 90034
- Application / Permit
- 20016-10000-27820
- Plan Check / Job No.
- B20LA20127
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (15) Telecommunication Transmitter - wireless
- Work Description
- MODIFICATIONS TO EXISTING ROOFTOP WIRELESS TELECOMMUNICATIONS FACILITY. WORK TO INCLUDE NEW RRUS AND EQUIPMENT CABINENT ANCHORAGE PER ZA-XXXX-XXXX-XXXX. 1. REMOVE (3) AIR21, (1) PER SECTOR. 2. ADD (3) AIRE6449, (1) PER SECTOR. 3. USE EXISTING BB6630 FOR L19 2ND CARRIER (ALL MIDBAND) 4. ADD (3) RADIO 4415 FOR 2ND L19/U19(MIX MODE) , USE 12X4.3-10 TO 4.3 -10 COAX JUMPERS-CONNECT TO OCTO 4 FT 5. GSM GOES TO THE AIR32 DB MIX MODE WITH 1ST L19. 6. ADD (1) 6160 AND (1) B160. 7. UPGRADE TO IZRE ROUTER. 8. ADD(1) BB6630 FOR L2500 AND (1) BB6648 FOR N2500. 9. ADD (2) 6X12 HCS 39M 6AWG FOR A&B AND (1) 6X12 HCS 30M. 10. AWG FOR C, (1 NEW FOR AIRE6449 AND DC FOR RADIO 4415) 11. ADD (1) PSU 4813 VOLTAGE BOOSTER.
- Permit Issued
- Issued on 7/14/2021
- Issuing Office
- Current Status
- Permit Expired on 7/24/2023
Permit Application Status History
| Submitted | 10/30/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 11/9/2020 | ZAW HAN |
| Corrections Issued | 11/16/2020 | ZAW HAN |
| Plan Check Approved | 6/21/2021 | CELESTE NGUYEN |
| Building Plans Picked Up | 7/13/2021 | APPLICANT |
| Issued | 7/14/2021 | APPLICANT |
| Permit Expired | 7/24/2023 | FARHAD DADBIN |
Permit Application Clearance Information
| Comm Cor/Mini-Mall | Cleared | 1/7/2021 | ANTONIO ISAIA |
| Plan Approval | Cleared | 1/7/2021 | ANTONIO ISAIA |
| ZA Case | Cleared | 1/7/2021 | ANTONIO ISAIA |
| Specific Plan | Cleared | 6/9/2021 | DYLAN SITTIG |
Contact Information
| Contractor | Metro Rf Services Inc; Lic. No.: 895236-B | 2320 S ARCHIBALD AVE ONTARIO, CA 91761 |
| Engineer | O'Sullivan,, Sean Michael; Lic. No.: C84392 | 25663 VIEW POINTE LAKE FOREST, CA 92630 |
Inspector Information
| FARHAD DADBIN, (310) 914-3922 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Special/Order Compliance | 7/24/2023 | Permit Expired | FARHAD DADBIN |