2210 S PENMAR AVE 90291
Certificate Information: 2210 S PENMAR AVE 90291
- Application / Permit
- 20016-10000-26974
- Plan Check / Job No.
- B20LA19558
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- CONVERSION OF (E) 2-STORY DUPLEX TO SFD (NO ADDITION). INTERIOR REMODEL OF EXISTING KITCHEN, BATHROOMS, MASTER SUITE, LAUNDRY ROOM. MOVE EXTERIOR STAIRS TO INTERIOR. 1 OF 2
- Permit Issued
- Issued on 8/3/2021
- Issuing Office
- Current Status
- CofO Issued on 3/1/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/24/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 12/3/2020 | CHUNG-WEN CHUANG |
| Corrections Issued | 12/16/2020 | CHUNG-WEN CHUANG |
| Quality Review Completed | 12/30/2020 | KESETE HAREGOT |
| Applicant returned to address corrections | 1/21/2021 | CHUNG-WEN CHUANG |
| Applicant returned to address corrections | 6/24/2021 | CHUNG-WEN CHUANG |
| Plan Check Approved | 7/12/2021 | CHUNG-WEN CHUANG |
| Issued | 8/3/2021 | APPLICANT |
| Building Plans Picked Up | 8/9/2021 | APPLICANT |
| CofO in Progress | 2/28/2023 | EVAN COOPER |
| Permit Finaled | 3/1/2023 | DANIEL ORRANTE |
| CofO Issued | 3/1/2023 | DANIEL ORRANTE |
| Permit Finaled | 3/1/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Specific Plan | Cleared | 2/3/2021 | PEDRO AYALA |
| "Q" conditions | Cleared | 6/30/2021 | KENTON TRINH |
| Eng Process Fee Ord 176,300 | Cleared | 7/8/2021 | DINAH GARIN |
| Sewer availability | Cleared | 7/8/2021 | DINAH GARIN |
Contact Information
| Contractor | Mardyks & Co Inc; Lic. No.: 1025120-B | 3923 REDWOOD AVENUE LOS ANGELES, CA 90066 |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 5330 ZELZAH AVE UNIT 7 ENCINO, CA 91316 |
Inspector Information
| RUBEN RIVAS, (310) 914-3981 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 10/6/2021 | Partial Inspection | JUAN VALENZUELA |
| Excavation/Setback/Form/Re-Bar | 11/1/2021 | Conditional Approval | DAVID FEILER |
| Floor/Roof Diaphrgm/Shear Wall | 1/7/2022 | Partial Approval | DAVID FEILER |
| Sewer | 1/7/2022 | Corrections Issued | DAVID FEILER |
| Rough-Elec/Plmb/HVAC | 1/12/2022 | Corrections Issued | DAVID FEILER |
| Underground Mechanical | 1/12/2022 | Partial Approval | DAVID FEILER |
| Rough-Elec/Plmb/HVAC | 1/24/2022 | Partial Approval | DAVID FEILER |
| Excavation/Setback/Form/Re-Bar | 2/1/2022 | Not Ready for Inspection | DAVID FEILER |
| Wood Frame | 2/16/2022 | Partial Approval | DAVID FEILER |
| Floor/Roof Diaphrgm/Shear Wall | 4/21/2022 | Approved | DAVID FEILER |
| PLUMBING-Rough | 4/25/2022 | Corrections Issued | DAVID FEILER |
| PLUMBING-Rough | 5/2/2022 | Partial Approval | DAVID FEILER |
| PLUMBING-Rough | 5/4/2022 | Approved | DAVID FEILER |
| ELECTRICAL-Rough | 5/10/2022 | Approved | DAVID FEILER |
| Deputy Wood Construction | 5/27/2022 | Conditional Approval | RICHARD STEINBACH |
| HVAC-Rough | 5/27/2022 | Corrections Issued | JESUS RODRIGUEZ |
| HVAC-Rough | 6/7/2022 | Approved | STEPHANIE SWANSON |
| BUILDING-Rough-Frame | 6/13/2022 | Corrections Issued | JESUS RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 6/13/2022 | Approved | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 6/21/2022 | Not Ready for Inspection | DAVID FEILER |
| Excavation/Setback/Form/Re-Bar | 7/5/2022 | Approved | DAVID FEILER |
| BUILDING-Rough-Frame | 7/19/2022 | Approved | DAVID FEILER |
| Green Building Rough | 7/19/2022 | Approved | DAVID FEILER |
| Interior/Exterior Lathing | 7/19/2022 | Partial Approval | DAVID FEILER |
| Insulation | 7/25/2022 | Approved | DAVID FEILER |
| Shower Pan | 8/10/2022 | Corrections Issued | DAVID FEILER |
| Drywall Nailing | 8/19/2022 | Approved | DAVID FEILER |
| Interior/Exterior Lathing | 8/19/2022 | Approved | DAVID FEILER |
| Shower Pan | 8/19/2022 | Approved | DAVID FEILER |
| Deck | 10/5/2022 | Approved | DAVID FEILER |
| Footing/Foundation/Slab | 10/11/2022 | Partial Inspection | DAVID FEILER |
| Underground Mechanical | 10/18/2022 | Not Ready for Inspection | DAVID FEILER |
| Underground Mechanical | 10/20/2022 | Partial Approval | ANDREW NAVE |
| HVAC-Rough | 11/10/2022 | Approved | JESUS RODRIGUEZ |
| ELECTRICAL-Final | 12/14/2022 | Approved | EVAN COOPER |
| SGSOV-Seismic Gas S/O Valve | 12/14/2022 | SGSOV Not Ready | EVAN COOPER |
| Smoke Detectors | 12/14/2022 | Approved | EVAN COOPER |
| Gas Test | 12/16/2022 | Approved | EVAN COOPER |
| SGSOV-Seismic Gas S/O Valve | 12/16/2022 | SGSOV Approved | EVAN COOPER |
| Service/Power Release | 12/16/2022 | Not Ready for Inspection | EVAN COOPER |
| HVAC-Final | 12/20/2022 | Corrections Issued | EVAN COOPER |
| Service/Power Release | 1/5/2023 | Approved | EVAN COOPER |
| HVAC-Final | 1/12/2023 | Approved | EVAN COOPER |
| PLUMBING-Final | 2/15/2023 | Approved | EVAN COOPER |
| Final | 2/24/2023 | Conditional Approval | EVAN COOPER |
| Final | 2/27/2023 | OK to Issue CofO | EVAN COOPER |