3660 S WATSEKA AVE 90034

Certificate Information: 3660 S WATSEKA AVE 90034

Application / Permit
20016-10000-20090
Plan Check / Job No.
B20LA14774
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT AS PER LABC CH 93. INSTALL 2 NEW SCCS AND 2 NEW SHEAR WALL.
Permit Issued
Issued on 1/28/2021
Issuing Office
Current Status
CofC Issued on 7/26/2021

Permit Application Status History

Submitted 8/19/2020 APPLICANT
Assigned to Plan Check Engineer 8/26/2020 JESSE VIDUYA
Corrections Issued 9/3/2020 JESSE VIDUYA
Quality Review Completed 9/4/2020 HANS SANTIAGO
Building Plans Picked Up 9/16/2020 APPLICANT
Applicant returned to address corrections 11/23/2020 JESSE VIDUYA
Applicant returned to address corrections 1/4/2021 JESSE VIDUYA
Plan Check Approved 1/7/2021 JESSE VIDUYA
Issued 1/28/2021 APPLICANT
OK for CofC 7/21/2021 GRANT WOODS
CofC Issued 7/26/2021 TED RIES

Permit Application Clearance Information

Specific Plan Cleared 12/7/2020 DYLAN SITTIG
Tenant Habitability Plan Cleared 1/26/2021 STEVEN HOFSTAD

Contact Information

Contractor Procon Builders Inc; Lic. No.: 977214-A 9526 TOPANGA CANYON BLVD      CHATSWORTH, CA 91311
Engineer Talebian,, Sasan; Lic. No.: C44216 12063A JEFFERSON BLVD      CULVER CITY, CA 90230

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 3/9/2021 Approved GRANT WOODS
Wood Frame 3/9/2021 Partial Approval GRANT WOODS
Deputy Drilled-In Anchors 3/10/2021 Conditional Approval GRANT WOODS
Deputy Steel/Welding 3/11/2021 Conditional Approval GRANT WOODS
Deputy Drilled-In Anchors 3/17/2021 Conditional Approval GRANT WOODS
Excavation/Setback/Form/Re-Bar 3/24/2021 Approved GRANT WOODS
Wood Frame 3/24/2021 Approved GRANT WOODS
Footing/Foundation/Slab 3/31/2021 Approved GRANT WOODS
Deputy Reinf. Concrete 4/1/2021 Conditional Approval GRANT WOODS
Wood Frame 4/8/2021 Approved GRANT WOODS
Interior/Exterior Lathing 4/16/2021 Approved GRANT WOODS
Final 6/4/2021 Not Ready for Inspection GRANT WOODS
SGSOV-Seismic Gas S/O Valve 6/4/2021 SGSOV Not Ready GRANT WOODS
Smoke Detectors 6/4/2021 Not Ready for Inspection GRANT WOODS
Final 7/7/2021 Not Ready for Inspection PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 7/7/2021 SGSOV Approved PAUL DAVIDSON
Smoke Detectors 7/7/2021 Approved PAUL DAVIDSON
Final 7/21/2021 OK for CofC GRANT WOODS