8720 N WOODLEY AVE 91343

Certificate Information: 8720 N WOODLEY AVE 91343

Application / Permit
20016-10000-20081
Plan Check / Job No.
B20LA14763
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Commercial
Primary Use
(15) Telecommunication Transmitter - wireless
Work Description
MODIFICATION TO EXISTING ROOFTOP WIRELESS SITE PER ZA-2008-0349-CUW 1. REMOVE 3 TMBX U19 AND 3 TMBX GSM AND ADD 3 AIR6449 B41 L2500+N2500 2. REPLACE 3 LNX 6514 6FT WITH 3 APXVAARR18 6FT OCTO ANTENNAS 3. REMOVE 3 RRUS11 B2 AND 3 RRUS01 B2s AND 3 RRU 4415 B25s NEAR ANTENNAS - CONNECT TO OCTO RFS AND CONFIGURE L19 2ND/U19 MIX MODE. 4. REPLACE 3 RRUS11 B12 WITH 3 RRU 4449 FOR L700/L600/N600 - CONNECT TO OCTO PORT 5. MOVE GSM TO AIR32D8 B2A TO CONFIGURE L19 1ST AND GSM MIX MODE 6. USE EXISTING BB5216/XMU FOR L600, L19 2ND CARRIER 7. ADD BB6630 FOR N600 INSIDE 6131 CABINET 1 B160 BATTERY CABINET 8. ADD 1 NEW ENCLOSURE 6160 SITE SUPPORT CABINET AND B160 BATTERY CABINET 9. ADD BB6630 INSIDE NEW ENCLOSURE 6160 CABINET FOR L2500 10. ADD BB6648 INSIDE NEW ENCLOSURE 6160 CABINET 11. ADD 3 6X12 HCS 40M 6AWG EACH FOR AIR6449s, 4415s, 4449s 1 PER SECTOR
Permit Issued
Issued on 12/16/2020
Issuing Office
Current Status
Permit Finaled on 2/9/2021

Permit Application Status History

Submitted 8/18/2020 APPLICANT
Assigned to Plan Check Engineer 8/19/2020 AMIR DANAI
Corrections Issued 8/19/2020 AMIR DANAI
Plan Check Approved 11/13/2020 AUNG SOE
Building Plans Picked Up 11/16/2020 APPLICANT
Issued 12/16/2020 APPLICANT
Permit Finaled 2/4/2021 ANDREW DORSO

Permit Application Clearance Information

"Q" conditions Cleared 11/13/2020 JESSE RAMOS
Plan Approval Cleared 11/13/2020 JESSE RAMOS
ZA Case Cleared 11/13/2020 JESSE RAMOS

Contact Information

Contractor Qualtek Wireless Llc; Lic. No.: 1042849-B 1150 FIRST AVE STE 600      KING OF PRUSSIA, PA 19406
Engineer O'Sullivan,, Sean Michael; Lic. No.: C84392 25663 VIEW POINTE      LAKE FOREST, CA 92630

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Final 1/12/2021 Not Ready for Inspection JEFFREY FULTON
SGSOV-Seismic Gas S/O Valve 1/12/2021 SGSOV Approved JEFFREY FULTON
Smoke Detectors 1/12/2021 Approved JEFFREY FULTON
Final 2/4/2021 Permit Finaled ANDREW DORSO