1522 S WOOSTER ST 90035
Certificate Information: 1522 S WOOSTER ST 90035
- Application / Permit
- 20016-10000-19849
- Plan Check / Job No.
- B20LA14645
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- Soft-Story seismic retrofit per LABC Chapter 93: INSTALL (3) SPECIAL CANTILEVERED COLUMN WITH GRADE BEAMS AT THE TUCK UNDER PARKING GARAGE AREA
- Permit Issued
- Issued on 11/4/2020
- Issuing Office
- Current Status
- CofC Issued on 8/4/2021
Permit Application Status History
| Submitted | 8/16/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 8/26/2020 | HANS SANTIAGO |
| Corrections Issued | 9/3/2020 | HANS SANTIAGO |
| Quality Review Completed | 9/8/2020 | DAVID CHANG |
| Plan Check Approved | 9/15/2020 | ANDREW SANTIAGO |
| Issued | 11/4/2020 | APPLICANT |
| OK for CofC | 8/3/2021 | BRUCE CAMPBELL |
| CofC Issued | 8/4/2021 | WINSTON DUNNING |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 10/29/2020 | MICHAEL SOTO |
Contact Information
| Contractor | Cal - Quake Construction Inc; Lic. No.: 759817-B | 636 NORTH FORMOSA AVENUE LOS ANGELES, CA 90036 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 743 S SIERRA VISTA AVE C ALHAMBRA, CA 91801 |
Inspector Information
| DARRYL ARNOLD, (213) 482-0341 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/18/2021 | Conditional Approval | DARRYL ARNOLD |
| Excavation/Setback/Form/Re-Bar | 4/8/2021 | Approved | DARRYL ARNOLD |
| Structural Steel Frame | 5/3/2021 | Approved | DARRYL ARNOLD |
| Wood Frame | 5/3/2021 | Conditional Approval | DARRYL ARNOLD |
| Interior/Exterior Lathing | 7/16/2021 | Conditional Approval | DARRYL ARNOLD |
| Interior/Exterior Lathing | 7/19/2021 | Conditional Approval | DARRYL ARNOLD |
| Final | 7/30/2021 | Corrections Issued | BRUCE CAMPBELL |
| METHANE-Final | 7/30/2021 | Approved | BRUCE CAMPBELL |
| SGSOV-Seismic Gas S/O Valve | 7/30/2021 | SGSOV Approved | BRUCE CAMPBELL |
| Smoke Detectors | 7/30/2021 | Approved | BRUCE CAMPBELL |
| Final | 8/3/2021 | OK for CofC | BRUCE CAMPBELL |