2029 W 29TH PL 90018

Certificate Information: 2029 W 29TH PL 90018

Application / Permit
20016-10000-16057
Plan Check / Job No.
B20LA11908
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
PARTIALLY ENCLOSED FRONT PORCH WILL BE RE-OPENED. MATCH RAILING ON EASTERN SIDE TO EXISTING ON WEST SIDE OF PORCH. REMOVE AND REPLACE (17) WINDOWS AND INSTALL NEW FRENCH DOOR PER HPOZ APPROVAL.REPLACE APPROXIMATELY 25 ROOFING SQUARES. BUILD OUT NEW POWDER ROOM AT FIRST FLOOR AND NEW MASTER RESTROOM AT SECOND FLOOR WITHIN EXISTING SQUARE FOOTAGE. NEW TANKLESS WATER HEATER.
Permit Issued
Issued on 8/25/2020
Issuing Office
Current Status
Permit Finaled on 12/1/2020

Permit Application Status History

Submitted 7/14/2020 APPLICANT
Assigned to Plan Check Engineer 7/14/2020 CRISTINA SALAZAR
Corrections Issued 7/15/2020 CRISTINA SALAZAR
Building Plans Picked Up 7/16/2020 APPLICANT
Plan Check Approved 8/25/2020 FERNANDO FLORES
Issued 8/25/2020 APPLICANT
Permit Finaled 12/1/2020 ROBERT MCDOWELL

Permit Application Clearance Information

City Hist. Cultural Monument Cleared 7/27/2020 MAX LODER
HPOZ Cleared 7/27/2020 MAX LODER
Historic monument Cleared 7/27/2020 MAX LODER

Contact Information

Contractor G A Design Build; Lic. No.: 941130-B 8449 EVEREST ST      DOWNEY, CA 90242

Inspector Information

SABAS ALONSO, (213) 202-3468 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Drywall Nailing 8/28/2020 Approved ROBERT MCDOWELL
Floor/Roof Diaphrgm/Shear Wall 8/28/2020 Approved ROBERT MCDOWELL
Rough-Elec/Plmb/HVAC 8/28/2020 Approved ROBERT MCDOWELL
BUILDING-Rough-Frame 11/23/2020 No Access for Inspection ROBERT MCDOWELL
ELECTRICAL-Final 11/23/2020 No Access for Inspection ROBERT MCDOWELL
Final 11/23/2020 No Access for Inspection ROBERT MCDOWELL
HVAC-Final 11/23/2020 No Access for Inspection ROBERT MCDOWELL
METHANE-Final 11/23/2020 Not Ready for Inspection ROBERT MCDOWELL
METHANE-Rough 11/23/2020 No Access for Inspection ROBERT MCDOWELL
PLUMBING-Final 11/23/2020 No Access for Inspection ROBERT MCDOWELL
SGSOV-Seismic Gas S/O Valve 11/23/2020 SGSOV Approved ROBERT MCDOWELL
Smoke Detectors 11/23/2020 No Access for Inspection ROBERT MCDOWELL
BUILDING-Rough-Frame 12/1/2020 Approved ROBERT MCDOWELL
Final 12/1/2020 Permit Finaled ROBERT MCDOWELL
METHANE-Final 12/1/2020 Approved ROBERT MCDOWELL
METHANE-Rough 12/1/2020 Approved ROBERT MCDOWELL
Smoke Detectors 12/1/2020 Approved ROBERT MCDOWELL